Regency ULTRAGLOOW G36D-LP PROPANE user manual

User manual for the device Regency ULTRAGLOOW G36D-LP PROPANE

Device: Regency ULTRAGLOOW G36D-LP PROPANE
Category: Indoor Fireplace
Manufacturer: Regency
Size: 4.04 MB
Added : 9/2/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Regency ULTRAGLOOW G36D-LP PROPANE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Regency ULTRAGLOOW G36D-LP PROPANE.

For your convenience

If looking through the Regency ULTRAGLOOW G36D-LP PROPANE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Regency ULTRAGLOOW G36D-LP PROPANE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Regency ULTRAGLOOW G36D-LP PROPANE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Regency ULTRAGLOOW G36D-LP PROPANE User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Regency ULTRAGLOOW G36D-LP PROPANE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Regency ULTRAGLOOW G36D-LP PROPANE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.regency-fi re.com
Owners &
G36D Zero Clearance Direct Vent Gas Fireplace
Installation Manual
MODELS: G36D-NG Natural Gas G36D-LP Propane
WARNING: If the information in these instructions are not followed exactly,
FOR YOUR SAFETY
a fi re or explosion may result causing property damage, personal injury
What to do if you smell gas:
or loss of life.
FOR YOUR SAFETY: Do not store or use gasoline or other fl ammable
Do not try to light any appliance.
vapors and liquids in the vicini

Summary of the content on the page No. 2

To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL. The G36D is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model G36D has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. P

Summary of the content on the page No. 3

TABLE OF CONTENTS Page Page Safety Label Operating Instructions Safety Label ............................................................... 4 Operating Instructions .............................................. 32 Lighting Procedure ................................................... 32 Installation Shutdown Procedure ................................................ 32 First Fire ................................................................... 32 Important Message .......

Summary of the content on the page No. 4

SAFETY LABEL This is a copy of the label that accompanies each G36D Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. NOTE: UltraGlow units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. For the State of Massachusetts, installation and repair must

Summary of the content on the page No. 5

INSTALLATION 14) Under no circumstances should any solid IMPORTANT: CLOTHING OR OTHER FLAMMABLE fuels (wood, paper, cardboard, coal, etc.) MATERIAL SHOULD NOT BE PLACED be used in this appliance. SAVE THESE ON OR NEAR THE APPLIANCE. INSTRUCTIONS 15) The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids). The G36D-NG or G36D-LP Direct Vent Fireplace must be installed in accordance with these in- GENERAL SAFETY Emissio

Summary of the content on the page No. 6

INSTALLATION This includes: MANUFACTURED 5) This appliance is Listed for bedroom instal- 1) Clocking the appliance to ensure the correct lations when used with a Listed Millivolt MOBILE HOME fi ring rate (rate noted on label 26,000 Btu/h) Thermostat. Some areas may have further after burning appliance for 15 minutes. ADDITIONAL requirements, check local codes before installation. REQUIREMENTS 2) If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow 6)

Summary of the content on the page No. 7

INSTALLATION 2) Frame in the enclosure for the unit with CLEARANCES MANTEL LEG framing material. The framed opening is 37-1/4" high x 36-1/4" wide x 17-3/8" deep CLEARANCES The clearances listed below are Minimum (946mm high x 921mm wide x 441mm distances unless otherwise stated: deep). Combustible mantel leg clearances as per diagram below: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest imp

Summary of the content on the page No. 8

INSTALLATION COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. These drawings are to scale at 1:6 (one inch = 6 inches) Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the pain

Summary of the content on the page No. 9

INSTALLATION 3) Attach the standoff securely to the top TopHeader with 2 screws per standoff (on opposite 10"dia.hole corners). throughwall 1/2" forFlex Drywall orforDuraVent "C" Screw Position: For a facing material depth of 1-1/4" 2" (32mm), the top facing support must be reversed. 3-1/2" 4" 17-1/8" Openingforgas connectio n Note: 40-1/2" (1029mm) is the minimum height for both fl ex termination or Simpson Dura-Vent venting. Top Facing Support and Side Nailing Strips 5) The unit does not

Summary of the content on the page No. 10

INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS 10 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace V V . Vertical Inside corner detail Termination Vertical Termination G V A 24" 24" 18" D V E H B B C M Fixed B V V Closed Openable Fixed Closed V Openable V F N B L V A B K V A B j A Air supply outlet Area where terminal is not permited Vent terminal A V A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) H= Not to be installed above a meter/regulator assembly withi

Summary of the content on the page No. 11

INSTALLATION VENTING UltraGlow Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the G36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 10. UltraGlow Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the G36D with a maximum

Summary of the content on the page No. 12

INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. R Description Simpson Dura-Vent Selkirk Amerivent R TM Direct VentGS Direct-Temp Direct Vent 6" Pipe Length, Galvanized 908 4DT-6 N/A 6" Pipe Length, Black 908B 4DT-6B N/A 7" Pipe Length, Galvanized N/A N/A 4D7 7" Pipe Length, Black N/A N/A 4D7B 9" Pipe Length, Galvanized 907 4DT-9 N/A 9" Pipe Length, Blac

Summary of the content on the page No. 13

INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations The minimum components required for a basic horizontal termination are: Flat Wall Installation Wall Thickness Vent Length 1 Horizontal Termination Cap (inches) Required (inches) o 1 90 Elbow 4" - 5-1/2" 6" 1 Rigid Pipe Adaptor 7" - 8-1/2" 9" 1 Wall Thimble 10" - 11-1/2" 12" 1 Length of pipe to suit wall thi

Summary of the content on the page No. 14

INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ULTRAGLOW DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 elbow (two 45 elbows equal one 90 elbow). Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. All Rigid Pipe Systems 4" inner diameter 6-5/8" outer diameter UltraGlow Flex Vent 4" inner diameter 6-7/8" inner di

Summary of the content on the page No. 15

INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ULTRAGLOW DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram below shows examples of horizontal termination arrangements using two 90 elbows (two 45 elbows equal one 90 elbow). o Note: 1) A maximum of two 90 elbows are permitted. o 2) A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90 elbows are used. 3) Minimum distance between elbows is 2 ft. (0.6m). 4) Determine the permitted r

Summary of the content on the page No. 16

INSTALLATION RIDID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS (Propane & Natural Gas) The G36D is approved for a maximum 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset o o o using two 90 elbows (two 45 elbows equal one 90 elbow) with Rigid Pipe vent systems for Propane and Natural Gas, as per diagram 1. The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, including a maximum 20" (0.5m) horizontal o o o offset using two 90 elbow (two 45 elbow

Summary of the content on the page No. 17

INSTALLATION The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas, as per the diagram 3. The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Rigid Pipe vent systems for o Propane and Natural Gas. Maximum two 45 elbows allowed. • Vent must be supported at offsets • Firestops are required at each fl oor level and whenever passing through a wall.

Summary of the content on the page No. 18

INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE Masonry chimneys may take various contours which the fl exible liner will accommodate. However, CONNECTED TO A CHIMNEY FLUE keep the fl exible liner as straight as possible, avoid unnecessary bending. SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. The Air Intake pipe must be attached to the inlet air collar of the termination cap. This appliance is designed to be attached to two 3" (76mm) co-linear alumin

Summary of the content on the page No. 19

INSTALLATION Venting Arrangements - Vertical Terminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 19

Summary of the content on the page No. 20

INSTALLATION b) Horizontal runs of vent must be HORIZONTAL supported every three feet. Wall straps are available for this purpose. INSTALLATIONS 5) Mark the wall for a 10" x 10" square hole. Install the vent system according to the The center of the square hole should line manufacturer's instructions included with up with the centerline of the horizontal pipe. the components. Cut and frame the 10 inch square hole in the exterior wall where the vent will be 1) Set the unit in its des


Alternative user manuals
# User manual Category Download
1 Regency 946-523/P User manual Indoor Fireplace 6
2 Regency 944-072 User manual Indoor Fireplace 1
3 Regency E21 User manual Indoor Fireplace 7
4 Regency E21-NG1 User manual Indoor Fireplace 2
5 Regency E21-LP2 User manual Indoor Fireplace 0
6 Regency Excalibur P90 User manual Indoor Fireplace 5
7 Regency Direct Vent Medium Gas Fireplace Bellavista B36X User manual Indoor Fireplace 0
8 Regency Excalibur P95 User manual Indoor Fireplace 0
9 Regency E21-NG2 User manual Indoor Fireplace 0
10 Regency E21-LP1 User manual Indoor Fireplace 0
11 Regency C34 User manual Indoor Fireplace 2
12 Regency F2400 User manual Indoor Fireplace 1
13 Regency Freestanding and Fireplace Insert Pellet Stove GF55 User manual Indoor Fireplace 0
14 Regency Freestanding and Fireplace Insert Pellet Stove GFI55 User manual Indoor Fireplace 0
15 Regency FREESTANDING WOODSTOVES F2100M User manual Indoor Fireplace 4
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1