New Buck Corporation MODEL FP-327-ZC user manual

User manual for the device New Buck Corporation MODEL FP-327-ZC

Device: New Buck Corporation MODEL FP-327-ZC
Category: Indoor Fireplace
Manufacturer: New Buck Corporation
Size: 1.46 MB
Added : 6/12/2014
Number of pages: 45
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for New Buck Corporation MODEL FP-327-ZC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with New Buck Corporation MODEL FP-327-ZC.

For your convenience

If looking through the New Buck Corporation MODEL FP-327-ZC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual New Buck Corporation MODEL FP-327-ZC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual New Buck Corporation MODEL FP-327-ZC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
New Buck Corporation MODEL FP-327-ZC User manual - Online PDF
Advertisement
« Page 1 of 45 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual New Buck Corporation MODEL FP-327-ZC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to New Buck Corporation MODEL FP-327-ZC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

NEW BUCK CORPORATION
MODEL FP-327-ZC
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.

− Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call y

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS Safety Information and Warnings ........................................................................................ 3 Installation ........................................................................................................................... 6 Fireplace and Framing Dimensions ..................................................................................... 7 Fireplace Clearances ..........................................................................

Summary of the content on the page No. 4

Page 2

Summary of the content on the page No. 5

SECTION I SAFETY INFORMATION WARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THE APPLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get f

Summary of the content on the page No. 6

5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shut off gas supply. - Do not try to light any appliance. - Do not touch any electrical switch; do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire department. 7

Summary of the content on the page No. 7

20. All heater screens must be kept clean when operating the gas logs. 21. . ”WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.” 22. Do not use this heater for burning trash or cooking. Never place matches, paper, garbage, or any other material on top of logs or into the flames. 23. Do not install or operate this heater in areas where impurities in the air exist (such as tobacco smoke or heavy cooking grease). P

Summary of the content on the page No. 8

SECTION II ZERO CLEARANCE INSTALLATION The installation must conform with local codes ,or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54. * This appliance may be installed in an After-Market Manufactured (Mobile) Home, where not prohibited by state or local codes. * (After Market: Completion of sale, not for the purpose of resale from the manufacturer). This appliance is only for use with the type of gas indicated on the ratin

Summary of the content on the page No. 9

Fireplace and Framing Dimensions (inches) NOTE: Do not obstruct air openings around appliance. Maintain adequate clearances around air openings. 32 3/16" 26 1/4" 30 3/16" 15 3/4" GAS LINE 31 7/8" 31 7/8" 3 1/4" 32 3/16" 7 1/2" 13 1/2" Figure 2 WARNING: Installation and repairs should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a professional ser- vice person. More frequent cleaning may be required due to

Summary of the content on the page No. 10

any combustible material other than wood flooring, it FIREPLACE CLEARANCES must be installed on a metal or wood panel extending its The fireplace may be placed directly on a combustible full width and depth. Alternatively, the carpeting, vinyl floor, against a combustible wall at marked clearances, or tile, etc. may be removed beneath the fireplace before on a raised wooden platform. installing. If the fireplace is to be installed on a raised wooden COMBUSTIBLE MATERIALS MUST NOT

Summary of the content on the page No. 11

FINISHING YOUR FIREPLACE There is a wide variety of finishing material brick and stone are made of non combustible available for your fireplace from formal wall materials before using them on the face of the treatments with marble and mantels, to rustic fireplace. Some of these products contain wood paneling, stone or brick. Non- combustible materials. Combustible wall combustible materials used in this installation coverings such as paneling or wallboard may such as slate, tile, mar

Summary of the content on the page No. 12

MANTEL PROFILES FOR ZERO CLEARANCE CABINET MUST BE FOLLOWED MANTEL 3/4" FLAT SURFACE CEILING NAILING FLANGE PICTURE. 1 COMBUSTIBLE MATERIAL 42" 3" 3 1/4" 2" 3/4" 10” 3 1/4" 7” 2" FP-327-ZC TOP TRIM (METAL) STAND OFF LOUVERS 2" HOOD MANTEL 3/4" FLAT SURFACE CEILING NAILING FLANGE PICTURE. 2 3" COMBUSTIBLE 12" MATERIAL 42" 3/4" 2" 13” 10" 2" FP-327-ZC TOP TRIM (METAL) STAND OFF LOUVERS 2" HOOD 2 1/2" FLAT SURFACE CEILING NAILING FLANGE PICTURE. 3 COMBUSTIBLE MATERIAL 42" MIN

Summary of the content on the page No. 13

INSTALLATION OF MODEL FP - 327- ZC WITH OPTIONAL WOODEN MANTEL (1) When choosing the right location for your heater and mantel keep the following in mind: NOTE: Due to high temperatures, this heater should be located out of traffic areas and away from furniture and draperies. NOTE: Kit No. (PAKDM327) Optional Wooden Mantel for FP-327-ZC. CAUTION: THE INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODES, ANSI Z

Summary of the content on the page No. 14

SIDE MANTEL (10) To light the heater, see “Lighting Instructions” pages 21 through 28. Make sure you have the right gas valve for Natural or LP gas. TOP MANTEL 1/2" WOOD SCREWS (9) REAR OF HEATER MANTEL BASE FIGURE 6 Page 12

Summary of the content on the page No. 15

SECTION VI AFTER MARKET MOBILE HOME INSTALLATION NOTE: See “Producing Adequate Ventilation” page 14. .THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET*, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY LOCAL CODES. *After Market: Completion of sale, not for the purpose of resale from the manufacturer. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.

Summary of the content on the page No. 16

PRODUCING ADEQUATE VENTILATION This section is for residential or manufactured (mobile) installation “This heater shall not be installed in a confined space or unusually tight construction unless pro- visions are adequate combustion and ventilation air.” The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space 3 whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8m per kw) of the aggregate input rating of all appliances installed in that spac

Summary of the content on the page No. 17

1. Determine the volume of the space (length x width x height). Length x Width x Height =_________cu.ft.(volume of space) EXAMPLE: 20 ft.(Length) x 16 ft.(Width) x 8 ft.(ceiling Height)= 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the m

Summary of the content on the page No. 18

VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconfined space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see Options 1 and 2, Figure 7). You can also remove door into adjoining room (see Option 3, Figure 7). WARNING REWORK WORKSHEET, ADDING THE SPACE OF THE ADJOINING UNCONFINED SPACE. THE COM

Summary of the content on the page No. 19

WARNING THIS APPLIANCE MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL- BURNING APPLIANCES IN YOUR HOME. VENTILATION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors. These spaces incl

Summary of the content on the page No. 20

WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS GAS CONNECTION Check gas type. Use only the type of gas indicated on the valve rating plate. If the gas type listed on the plate is not your type of gas supply, DO NOT INSTALL. Contact your dealer for proper model. Always use an external regulator for all LP heaters to reduce the supply tank pressure to a maximum of 13" W.C. This is in addition to the regulator furnished with the


Alternative user manuals
# User manual Category Download
1 New Buck Corporation 34 User manual Indoor Fireplace 0
2 New Buck Corporation 384 User manual Indoor Fireplace 0
3 New Buck Corporation 42ZCBB User manual Indoor Fireplace 1
4 New Buck Corporation CR8T User manual Indoor Fireplace 0
5 New Buck Corporation 329 User manual Indoor Fireplace 0
6 New Buck Corporation 85 User manual Indoor Fireplace 0
7 New Buck Corporation DV1000 User manual Indoor Fireplace 0
8 New Buck Corporation DV23ZC User manual Indoor Fireplace 0
9 New Buck Corporation 74 User manual Indoor Fireplace 1
10 New Buck Corporation FP-BR-10-ZC User manual Indoor Fireplace 0
11 New Buck Corporation 81 User manual Indoor Fireplace 0
12 New Buck Corporation 32 User manual Indoor Fireplace 0
13 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
14 AEG Royal Belmont G20 User manual Indoor Fireplace 3
15 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
16 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
17 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1