New Buck Corporation DV1000 user manual

User manual for the device New Buck Corporation DV1000

Device: New Buck Corporation DV1000
Category: Indoor Fireplace
Manufacturer: New Buck Corporation
Size: 1.87 MB
Added : 6/12/2014
Number of pages: 38
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for New Buck Corporation DV1000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with New Buck Corporation DV1000.

For your convenience

If looking through the New Buck Corporation DV1000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual New Buck Corporation DV1000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual New Buck Corporation DV1000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
New Buck Corporation DV1000 User manual - Online PDF
Advertisement
« Page 1 of 38 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual New Buck Corporation DV1000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to New Buck Corporation DV1000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DV1000
ZERO CLEARANCE DIRECT VENT GAS FIREPLACE
WITH L.P. (Liquid Propane) or Natural Gas/ Millivolt System
This appliance is not convertible for use with other gases, unless a certified kit is used.
Approved By:
WARNING: If the information in these instructions are not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss of life.
⎯ Do not store or use gasolin

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS Introduction .......................................................................................................................... 2 Firebox Cover Door Removal……………………………………………………………..3 Specifications……………………………………………………………………………...5 Minimum Framing Dimensions……………………………………………………………6 Vent Terminal Clearance…………………………………………………………………..7 Determining The Location…………………………………………………………………8 Minimum Clearances To Combustible Material…………………………………………..8 Direct Vent Termi

Summary of the content on the page No. 4

DANGER: Carbon monoxide poisoning may lead to death! This appliance is a vented product. This appliance will not produce any gas leakage into your home if properly installed. This appliance must be properly installed by a qualified ser- vice person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, gas leak- age can occur. Carbon Monoxide Poisoning: Early signs of carbon mon

Summary of the content on the page No. 5

INTRODUCTION AND SAFETY FOR INSTALLATION AND OPERATION This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system. Please read and understand these instructions before beginning your installation. The model DV1000 is a sealed combustion, air circulating gas appliance designed for residential and mobile home applications. The appliance must be installed with Magnaflex DV4-F vent system that is routed to outside atmospher

Summary of the content on the page No. 6

NOTE: Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. When choosing a location for your DV1000 in your home be sure to provide the foll

Summary of the content on the page No. 7

1. The top louver assembly must be removed first. To remove the top louver assembly you must place your hands one at the bottom left corner and the other at the bottom right corner of the lou- ver assembly. Then with both hands lift up and outwards to release the louver clips from the stove body. After removing the louver assembly place it in a safe place until time to reinstall. 2. The bottom louver assembly must be in the open position to access the firebox cover door fas- teners. The bott

Summary of the content on the page No. 8

DV1000 SPECIFICATIONS 38-1/8” 36” 33-1/2” 16-15/16” TOP STANDOFF(S) SIDE STANDOFF(S) 27-1/8” REAR STANDOFF 13-9/16” 16-1/2” 15-1/8” 10-5/32” 24-1/4” FIGURE 2 2-1/2” 6” NOTE: When the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Page 5

Summary of the content on the page No. 9

MINIMUM FRAMING DIMENSIONS 40-1/8” 2-1/2” Note: “Front side and top stand- off (s) are permanently attached 17” * to the front trim panels. The front trim panels are attached by the manufacturer and must not RIGHT LEFT be removed or altered in anyway FRONT * SIDE * SIDE * for any reason.” 37-7/16” * 17” * Combustible Adjacent Side Wall. 37-7/16”* 6” FIGURE 3 Note: “Only trim kit(s) supplied by the manufacturer shall be used in the installation

Summary of the content on the page No. 10

VENT TERMINAL CLEARANCES FIGURE 4 Page 7

Summary of the content on the page No. 11

DETERMINING THE LOCATION FOR DV1000 Note: The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Instal- lation Code, CSA B149.1. This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appli-

Summary of the content on the page No. 12

DV1000 DIRECT VENT TERMINATION INSTALLATION INSTRUCTIONS (MAGNAFLEX) Read the instructions in this manual completely before installing the DV1000 appliance with the Magnaflex vent system. Magnaflex Venting systems are packaged with installation instruc- tions, the instructions must be followed exactly for your safety and to prevent voiding the war- ranty of your appliance and venting syste

Summary of the content on the page No. 13

∗ The termination cap must be positioned so that the embossed arrow is pointed up. ∗ Ensure that the venting system exits the structure through a sidewall or similar structure and does not terminate less than 12 inches (305mm) above the ground. ∗ Ensure that the venting system is located above the snow line in geographical areas where snow accumulates. PRE-INSTALLATION INFORMATION: Items Required For Installation: Tools

Summary of the content on the page No. 14

8. Plan your installation. Set the appliance in place and survey how best to vent the appliance. Se- lect the appropriate termination kit for the installation. Read the vent pipe manufacturers in- structions and the appliance manufacturers instruction manual before either. After vent configu- ration has been decided, stretch the flex components out, then trim off what will not be needed. A temporary fit up will determine this. Once the vent length has been determined and the neces- sary parts a

Summary of the content on the page No. 15

OPTIONAL DV1000 REAR HORIZONTAL VENT TERMINATION FIREPLACE This appliance has a rear vent termination option. (you must purchase a DV1000 with this op- tion from your dealer) Use termination kit #PP-DVVK-4F-1 only. This installation option can only be used exactly as shown in figure 5. Follow the direction provided with the termination kit. (see Horizontal Air Termination Installation page ) * 20” “From the rear of the unit to the out- 3/4” WALL BOARD side wall.” 2” x 4” WALL STUD 3/

Summary of the content on the page No. 16

DV1000 STANDARD HORIZONTAL TERMINATION INSTALLATIONS HORIZONTAL TERMINATION CAP ASSEMBLY 12” 45-1/2” 10-1/2” From Rear Standoff To Outside Wall. MINIMUM INSTALLATION NOTE: Horizontal pipe installations must be supported with Wall Straps every 3 feet. WALL STRAPS 56”Max. & 49-1/2” Min. *16” 53” Max. & 11” Min. From Rear Standoff To Outside Wall. MAXIMUM INSTALLATION FIGURE 10 Page 13

Summary of the content on the page No. 17

DV1000 STANDARD VERTICAL CHASE TERMINATION INSTALLATIONS VERTICAL TERMINATION CAP ASSEMBLY 30 FT. MAX. WALL STRAPS NOTE: Vertical pipe installations must be supported with Wall Straps every 8 feet. FLEX PIPE (ONLY) 3 FT. MIN. DV1000 FRONT FIGURE 11 Page 14

Summary of the content on the page No. 18

REMOVABLE INNER BOTTOM PAN ASSEMBLY The DV1000 is equip with a removable Inner Bottom Pan Assembly for service purposes only. The burner control assembly should only be accessed by this procedure by a qualified service technician, or by the manufacturer. Follow the instructions and diagrams below. 1. Turn gas OFF at equipment shut OFF 2 valve, and disconnect union located at Right side of control valve. Remove 3 Cover Door, see pages 3 & 4. 2. Remove the 4 scre

Summary of the content on the page No. 19

GAS SUPPLY CONNECTION CHECK GAS TYPE Use proper gas type for the burner system you are installing. If you have conflicting gas types, do not install burner system. See dealer where you purchased the stove and burner system for proper burner system according to your gas type. INSTALLING GAS PIPING TO APPLIANCE Installation Items Needed Before installing the appliance make sure you have the items listed below. • External regulator (supplied

Summary of the content on the page No. 20

Pressure Testing Gas Supply Piping System Note: The appliance and its appliance main valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi. (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi. (3.5 kPa). Test Pressures In Excess of 1


Alternative user manuals
# User manual Category Download
1 New Buck Corporation 34 User manual Indoor Fireplace 0
2 New Buck Corporation 384 User manual Indoor Fireplace 0
3 New Buck Corporation 42ZCBB User manual Indoor Fireplace 1
4 New Buck Corporation CR8T User manual Indoor Fireplace 0
5 New Buck Corporation 329 User manual Indoor Fireplace 0
6 New Buck Corporation 85 User manual Indoor Fireplace 0
7 New Buck Corporation DV23ZC User manual Indoor Fireplace 0
8 New Buck Corporation 74 User manual Indoor Fireplace 1
9 New Buck Corporation MODEL FP-327-ZC User manual Indoor Fireplace 0
10 New Buck Corporation FP-BR-10-ZC User manual Indoor Fireplace 0
11 New Buck Corporation 81 User manual Indoor Fireplace 0
12 New Buck Corporation 32 User manual Indoor Fireplace 0
13 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
14 AEG Royal Belmont G20 User manual Indoor Fireplace 3
15 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
16 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
17 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1