Monessen Hearth M400BFC user manual

User manual for the device Monessen Hearth M400BFC

Device: Monessen Hearth M400BFC
Category: Indoor Fireplace
Manufacturer: Monessen Hearth
Size: 1.91 MB
Added : 4/12/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Monessen Hearth M400BFC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Monessen Hearth M400BFC.

For your convenience

If looking through the Monessen Hearth M400BFC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Monessen Hearth M400BFC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Monessen Hearth M400BFC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Monessen Hearth M400BFC User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Monessen Hearth M400BFC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Monessen Hearth M400BFC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

M400BFC
Balanced Flue (Closed Combustion)
Heat-Circulating Fireplace
Homeowner’s Installation and
Operating Manual
647
BFC cover
8/18/00 djt
For use in the U.S. / Canada
Underwriter’s Laboratories
Report No. MH7603
DO NOT DISCARD THIS MANUAL: Retain for future use.
87D1505 12/09 Rev. 3

Summary of the content on the page No. 2

M400BFC Balanced Flue Heat-Circulating Fireplace Table of Contents Safety Information ......................................................................................3 Specifications and Framing .......................................................................4 Parts Identification ....................................................................................6 Chimney Requirements ............................................................................7 Planning Inf

Summary of the content on the page No. 3

M400BFC Balanced Flue Heat-Circulating Fireplace Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possible fire hazard and will void the warranty. Any such action may possibly cause a fire hazard. Description Consult local building codes to ensure that you are in The M400BFC fireplace is a solid fuel, woodburning complian

Summary of the content on the page No. 4

M400BFC Balanced Flue Heat-Circulating Fireplace M400BFC Balanced Flue Heat-Circulating Fireplace " Rough (624mm) " Opening 13 " Dia. (197mm) Depth (343mm) 51 " (1297mm) 11" Dia. " " (13mm) (179mm) (610mm) 8" Dia. 23" (203mm) " Recessed (584mm) (16mm)Nailing Flange Rough Opening Width 43" (1092mm) Rough Opening " (179mm) Height " " (902mm) 32 " (829mm) Gas Line 35" Gas Line 39 " Access " (889mm) Access 36" (997mm) (533mm) (914mm) " " " (914mm) " (176mm) (246mm)

Summary of the content on the page No. 5

M400BFC Balanced Flue Heat-Circulating Fireplace Termination Cap Storm Collar Pan Flashing Batt Insulation (Cut out around firestop) Draftstop Firestop Ceiling Level Standoff Trim Ledge Standoff Surround Glass Door Gas Line Ac- cess Hole (Each Side) Romex Pigtail Gas Line Access Knock- out (Each Side) Air Inlet Basket Grate Bottom Grille Top Grille and Air Outlet Metal Safety Strip(s) Shown not inplace (1,2 or 3 pieces) Nailing Flange FP554c Fig. 2 Fireplace and chase parts identification. FP

Summary of the content on the page No. 6

M400BFC Balanced Flue Heat-Circulating Fireplace Chimney Requirements - Offset Installations Offset CHIMNEY FLUE EXIT Rise Chimney Section IWF282 30° Elbow FP282 30˚ Elbow Offsets Return Elbow MBUF B G A 5/26/96 1’ 1 ¹⁄₂' 3’ 4’ Offset Rise G 30° 0 0 0 0 0 3” 11” Offset 1 0 0 0 0 8 Z\v" 20" D Elbow 0 1 0 0 0 11 Z\v" 25 Z\v" E Rise 2 0 0 0 0 13 Z\x" 29 Z\v" 6 FT. TCS8A 1 1 0 0 0 16 Z\x" 34 Z\v" 30° C Support 0 0 1 0 0 20 Z\v" 40 C\v" Return H Elbow 2 1

Summary of the content on the page No. 7

M400BFC Balanced Flue Heat-Circulating Fireplace Planning Information Preplanning an installation is very important to ensure The Ten Foot Rule safety and to save time and money. An installer must Major U.S. building codes specify a minimum chimney predetermine where a fireplace will be set and how the height above the roof top. The “Ten Foot Rule” is a fire chimney system will be run. safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exc

Summary of the content on the page No. 8

M400BFC Balanced Flue Heat-Circulating Fireplace Chimney Supports Installation The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9 m) above the hearth. Chimney supports are required if the vertical Insulating Fireplace Enclosure height exceeds 30’ (9 m). Locate chimney supports for Cold Climates at ceiling holes or other structural framing at 30’ (9 m) heights. Spacing between chimney supports must If you live in a cold climate, it is not require

Summary of the content on the page No. 9

M400BFC Balanced Flue Heat-Circulating Fireplace NOTE: Check local building codes to determine if junction box is required at the romex pigtail/house wire connection Also check junction box and speed control (SCVS) installation instructions. Hard Flat Surface The Model FKSX-A blower assembly is preinstalled in the M400BFC. Fireplace Electrical Coverplate Romex Pigtail (Provided) Wire Nuts (Not pro- vided) Insulation Black Ground Platform White House Wiring FPC555a (120V 60Hz) FP1062 Fig

Summary of the content on the page No. 10

M400BFC Balanced Flue Heat-Circulating Fireplace Ceiling Chimney Hole/ Chimney Centerline Possible Obstructions Actual Center- The size of the hole in ceiling will vary with the angle at point which the chimney passes through ceiling. Drive a nail up through ceiling at marked chimney cen- 8 " (222mm) ter point. Go to floor above and see where hole will be cut. Check to see where existing ceiling joists and other possible obstructions are located...i.e. wiring, plumbing etc... If necessar

Summary of the content on the page No. 11

M400BFC Balanced Flue Heat-Circulating Fireplace Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 Z\x” (38 mm), allowing the remainder to extend in front of firebox. Overlap strips at least 1/2” (13 mm) to provide a posi- tive joint. (Flat safety strips are packed with fireplace.) Metal Safety Strips (Fig. 12) (1,2 or 3 pcs.) Safety strips are used to ens

Summary of the content on the page No. 12

M400BFC Balanced Flue Heat-Circulating Fireplace Installing the Pipe Section Chimney System Pipe Start by attaching the first chimney section to the collar Rim on top of the fireplace. Hem Lance Install the pipe as pictured in Figure 14. When you Pipe get a good lock, you will hear the pipe clearly snap Hem together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mo

Summary of the content on the page No. 13

M400BFC Balanced Flue Heat-Circulating Fireplace Firestop spacers are not available for, nor are they A chimney support is 2 Z\x" (64 mm) long when installed. required on vertical walls. Consider this dimension when determining how many straight chimney sections are needed. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer. If you NOTE: Chimney supports are generally used in long seal this area, it may cause a fire hazard. runs in a chase inst

Summary of the content on the page No. 14

M400BFC Balanced Flue Heat-Circulating Fireplace Check the chimney top installation instructions for details on how high above the roof top the chimney sec- Air Space Clearances tions (all pipes) should extend. Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas). Installing Top Housing or Termination Follow the installation instructions provided with the MHSC chimney termination you have selected. 2” Installing Chimney in a Chase Standoff Refer to Page 4, Figure 2 for a

Summary of the content on the page No. 15

M400BFC Balanced Flue Heat-Circulating Fireplace Combustible 12" Mantel Shelf (305mm) and Trim Max. Finished Wall 1 Z\x" Stud (38mm) 12" (305mm) Standoff Min. 6" Noncombustible Material (159mm) Min. Circulating Front Fireplace Opening Side View Z\x" 2 x 4 Stud Finished Wall Must be sealed with noncom- Fireplace bustible material Front FP531b Fig. 19 Mantel clearance. FP531b Face Plate mantel clearances 9/03 djt * C 1 Z\x" * * Ref. B Combustible materials are permitted within a shaded ar

Summary of the content on the page No. 16

M400BFC Balanced Flue Heat-Circulating Fireplace Side Wall Protection Hearth Installation Adjacent combustible side walls that are within mini- A hearth extension is required to protect a combustible mum dimensions shown in Figure 24 of the fireplace floor in front of the fireplace. Refer to Figure 21 for mini- opening must be protected with MHSC Wall Shield mum dimensions and mounting detail. Model SP40 or a specifically built wall shield described Note: Hearth Extension must not cover th

Summary of the content on the page No. 17

M400BFC Balanced Flue Heat-Circulating Fireplace WARNING: Hearth extension must be installed in Side View Wall Covering accordance with Figure 23 and must not cover the bottom front opening of the circulating model. Noncombustible Alternate noncombustible materials may be used pro- 2 x 4” Header Decorative Fac- - Do not notch at viding the (total) thermal resistance (Rt value) of the al- ing standoffs ternate material employed is greater than or equal to R = 1.09 Thermal resistance (R) o

Summary of the content on the page No. 18

M400BFC Balanced Flue Heat-Circulating Fireplace Operation Hole in Outer Casing Fireplace Top View Before the first fire, the location of the upper refractory baffle (ceiling panel) should be checked. This part floats 1" intentionally and may move out of place during ship- Min. Supply Gas Line ping or installation of the fireplace. If the baffle is out Line Tube of place, the resulting improper air flow will cause dirty Ceramic Repack Insu- glass and improper combustion. The baffle should

Summary of the content on the page No. 19

M400BFC Balanced Flue Heat-Circulating Fireplace 4 3 1 5 2 6 8 10 15 9 16 14 7 12 11 13 18 29 17 27 26 28 21 19 23 20 22 25 24 23 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. M400BFC Balanced Flue Fireplace 647 BFC parts 2008 Ref. Description M400BFC 2/08 djt 1. Top Grille - Painted 3126160 2. Bottom Grille - Painted 3126160 3. Grate Assembly 7579218 4. Left Door Assembly Complete 300

Summary of the content on the page No. 20

M400BFC Balanced Flue Heat-Circulating Fireplace M400BFC Balanced Flue Fireplace (continued) Ref. Description M400BFC 17. Blower Assembly - FKSX-A 20000620 18. Grate Retainer 2353179 19. Junction Box Assembly 3126161 20. Ceramic Glass Panel (two per fireplace) 30004352 21. Flat Gasket 3/4” Wide (two per fireplace) 20013997 22. Knob (two per fireplace) 1600657 23. Bushing (four per fireplace) 1201895 24. Pan Hd, PH 1/4-20 x 1 Black (two per fireplace) 1200907 25. Spacer (two per firepl


Alternative user manuals
# User manual Category Download
1 Monessen Hearth 36" and 42" Wood Burning Fireplaces BWB400IA User manual Indoor Fireplace 1
2 Monessen Hearth 36" and 42" Wood Burning Fireplaces BWBC500A User manual Indoor Fireplace 0
3 Monessen Hearth 36" and 42" Wood Burning Fireplaces BWB500IA User manual Indoor Fireplace 0
4 Monessen Hearth 36CDVXRRN User manual Indoor Fireplace 0
5 Monessen Hearth 36" and 42" Wood Burning Fireplaces BWBC500IA User manual Indoor Fireplace 1
6 Monessen Hearth 36CDVXTRN User manual Indoor Fireplace 0
7 Monessen Hearth 36" and 42" Wood Burning Fireplaces BWB500A User manual Indoor Fireplace 1
8 Monessen Hearth 424WBST User manual Indoor Fireplace 0
9 Monessen Hearth 624BVCR User manual Indoor Fireplace 0
10 Monessen Hearth 624BVPF User manual Indoor Fireplace 2
11 Monessen Hearth 36" and 42" Wood Burning Fireplaces BWBC400IA User manual Indoor Fireplace 0
12 Monessen Hearth 624BVST User manual Indoor Fireplace 0
13 Monessen Hearth 624BVCL User manual Indoor Fireplace 0
14 Monessen Hearth 36" and 42" Wood Burning Fireplaces BWBC400A User manual Indoor Fireplace 0
15 Monessen Hearth 624DVCLC User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1