Heat & Glo LifeStyle 6000TR-OAK-IPI user manual

User manual for the device Heat & Glo LifeStyle 6000TR-OAK-IPI

Device: Heat & Glo LifeStyle 6000TR-OAK-IPI
Category: Indoor Fireplace
Manufacturer: Heat & Glo LifeStyle
Size: 1.52 MB
Added : 2/20/2014
Number of pages: 35
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Heat & Glo LifeStyle 6000TR-OAK-IPI. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Heat & Glo LifeStyle 6000TR-OAK-IPI.

For your convenience

If looking through the Heat & Glo LifeStyle 6000TR-OAK-IPI user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Heat & Glo LifeStyle 6000TR-OAK-IPI on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Heat & Glo LifeStyle 6000TR-OAK-IPI to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Heat & Glo LifeStyle 6000TR-OAK-IPI User manual - Online PDF
Advertisement
« Page 1 of 35 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Heat & Glo LifeStyle 6000TR-OAK-IPI but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Heat & Glo LifeStyle 6000TR-OAK-IPI. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Manual
Installation and Operation
Models:
6000TR-OAK
6000TR-OAK-IPI
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IMPROPER INSTALLA-
GUIDE MUST BE LEFT WITH APPLIANCE FOR
TION, ADJUSTMENT, ALTERATION,
FUTURE REFERENCE.
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
WARNING: IF THE INFORMATION
ASSISTANCE OR ADDITIONAL INFOR-
IN THESE INSTRUCTIONS IS NOT
MATION CONSULT A QUA

Summary of the content on the page No. 2

SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully ! ! described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !

Summary of the content on the page No. 3

TABLE OF CONTENTS Safety and Warning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes ............................................... 8 Appliance Certification................................................................... 8 Installation Codes.......................................................................... 8 High Altitude Installations ...........

Summary of the content on the page No. 4

6000TR-OAK 6000TR-OAK-IPI Service Parts Beginning Manufacturing Date: 4-01 (NG, LP) Exploded Parts Diagram Ending Manufacturing Date: 6-06 3 1 2 13 4 5 12 6 Log Set Assembly 9 7 10 11 8 Part number list on following page. 4 Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

Summary of the content on the page No. 5

Service Parts List 6000TR-OAK, 6000TR-OAK-IPI IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order- ing, supply serial and model numbers to ensure correct service parts. ITEM COMMON PARTS SERIAL # PART NUMBER PRE 002324002 385-130 1Surround POST 002324002 2026-108 2 Hood SRV60-143-BK 3 Glass Door Assembly GLA-6TROC PRE 002324002 SRV383-338A 4 Burner NG, LP POST 002324002 SRV2025-007A 5 Log Grate 383-360A 6 Oak Log Set Assembl

Summary of the content on the page No. 6

6000TR-OAK-IPI Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: 6-06 3 Intermittent Pilot Ignition 13 Valve Assembly 10 12 11 9 1 2 6 8 4 7 5 ITEM DESCRIPTION SERIAL # PART NUMBER PRE 002324002 550-169 1 Valve Bracket POST 002324002 2025-101 2 Flex Ball Valve Assembly 302-320A 3 Ground Strap 2025-512 4 ON/OFF Rocker Switch 060-521A 5Valve NG 750-500 5 Valve LP 750-501 6 Burner Orifice NG (#37C) 582-837 6 Burner Orifice LP (#52C) 5

Summary of the content on the page No. 7

6000TR-OAK Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: 6-06 Standing Pilot Ignition 6 5 Valve Assembly 7 12 3 8 9 10 11 4 1 2 ITEM DESCRIPTION SERIAL # PART NUMBER 1 ON/OFF Rocker Switch 060-521A 2Valve NG 060-522 2 Valve LP 060-523 PRE 002324002 477-301A 3 Flexible Gas Connector POST 002324002 383-302A 4Wire Assembly 049-552A 5Pilot Assembly NG 485-510A 5Pilot Assembly LP 485-511A 6 Pilot Bracket 385-164 PRE 002324002 319

Summary of the content on the page No. 8

Approvals and Codes 1 High Altitude Installations Appliance Certification U.L. Listed gas appliances are tested and approved with- The Heat & Glo fireplace models discussed in this Installers out requiring changes for elevations from 0 to 2,000 feet in Guide have been tested to certification standards and listed the U. S. A. and in Canada. by the applicable laboratories. When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by Certifica

Summary of the content on the page No. 9

Inspection NOTE: The following requirements reference various The state or local gas inspector of the side wall horizontally Massachusetts and national codes not contained in vented gas fueled equipment shall not approve the installa- this document. tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with Requirements for the Commonwealth of the provisions of 248 CMR 5.08(2)(a)1 through 4. Massachusetts Exemptions The following equi

Summary of the content on the page No. 10

Getting Started 2 The Heat & Glo Warranty will be voided by, and Heat & Glo Introducing the Heat & Glo Gas Fireplaces disclaims any responsibility for, the following actions: Heat & Glo direct vent gas fireplaces are designed to oper- • Installation of any damaged fireplace or vent system ate with all combustion air siphoned from outside of the component. building and all exhaust gases expelled to the outside. • Modification of the fireplace or direct vent system. The information contained in th

Summary of the content on the page No. 11

28 1/2 [724mm] 14 1/4 [362mm] 21 1/2 [548mm] 8 [203mm] 11 5/8 [297mm] VENT COLLARS 8 ELECTRICAL [203mm] ACCESS VENT COLLARS GAS LINE ACCESS 34 5/8 38 25 1/4 [965mm] [879mm] [642mm] 26 7/8 2 1/8 3 1/2 [682mm] [55mm] [90mm] 36 1/8 [916mm] 12 3/4 [323mm] 6 7/8 [174mm] 41 [1040mm] TOP STANDOFFS TOP VENT COLLARS REAR VENT COLLARS HOOD TRIM DOOR RATING PLATE AND LABELS GAS LINE ACCESS GAS ELECTRICAL ACCESS CONTROLS Figure 1. Diagram of the 6000TR-OAK, 6000TR-OAK-IPI 11 Heat & Glo • 6000TR-OAK, 6000

Summary of the content on the page No. 12

1” MIN. (25mm) B A Installing the Fireplace 3 Constructing the Fireplace Chase A chase is a vertical box-like structure built to enclose the gas fireplace and/or its vent system. Vertical vents that run D E on the outside of a building may be, but are not required to be, installed inside a chase. C CAUTION: TREATMENT OF FIRESTOP SPACERS AND 1/2” MIN. (13mm) CONSTRUCTION OF THE CHASE MAY VARY WITH THE AB C D E TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT 42” 22” 36” 51” 72” SUBSTITUTES FOR THE RE

Summary of the content on the page No. 13

Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is CAUTION: MEASURE FIREPLACE DIMENSIONS AND set in place. Framing should be positioned to accommo- VERIFY FRAMING METHODS AND WALL COVERING date wall coverings and fireplace facing material. The dia- DETAILS BEFORE FRAMING. gram below shows framing reference dimensions. Framing should be constructed of 2 X 4 lumber or heavier. Noncombustible zone is defined by 3” above the elbow for the entire width and

Summary of the content on the page No. 14

DVP90ST 4 6 12 DVP4 DVP6 DVP12 14-1/4 12-3/16 2 MAX. MIN. 24 36 DVP12A 48 9-7/8 DVP24 O 45.0 10-1/4 DVP45 DVP36 11-1/4 7-1/4 1-1/4 TYP DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 4. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) 14 Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

Summary of the content on the page No. 15

Step 3. Installing the Vent System A. Vent System Approvals Identifying Vent Components These models are approved to use DVP-series direct vent The vent systems installed on this gas fireplace may in- pipe components and terminations (see Figures 4 and 5). clude one, two, or three 90° elbow assemblies. The rela- Approved vent system components are labeled for identifi- tionships of vertical rise to horizontal run in vent configura- cation. This pipe is tested and listed as an approved com- t

Summary of the content on the page No. 16

Flue Restrictor Instructions CAP 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7). STRAIGHT UP VERTICAL VENTING V (FT.) 40' MAX. (12.4 M) V EXHAUST SHIELD NOTE: On vertical venting configurations over 10 feet install the flue restrictor (385-128). See flue restric- tor installation instructions. FLUE RESTRICTOR Figure 7 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figu

Summary of the content on the page No. 17

3. Match the amount of vertical you have in the sys- tem with the chart to find the appropriate position HORIZONTAL VENTING to set the Flue Restrictor (see Figure 9). Kit No. H Max. Run DVP-TRAP 24" (610 mm) - CHART - Top Vent Top Vent Rear Vent Rear Vent Vertical NG LP NG LP No No No 4' 1-1 Restrictor Restrictor Restrictor No 8' 2-2 1-2 1-1 Restrictor 15' 3-3 3-2 2-2 1-2 20' 3-4 3-3 3-3 2-3 25' 3-4 3-3 3-3 2-3 30' 4-4 3-4 3-4 3-3 H 90-DEGREE 35' 4-4 3-4 3-4 3-3 ELBOWS 40' 5-4 4-4 4-4 3-4 45-DEG

Summary of the content on the page No. 18

VENTING WITH ONE (1) 90° ELBOW V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m) V NOTE: On vertical venting configurations, where the vertical component is over 10 feet, install the flue restrictor included in the manual bag assembly to improve flame appearance. H Figure 12. Venting with One 90° Elbow VENTING WITH ONE (1) 90° ELBOW

Summary of the content on the page No. 19

VENTING WITH TWO (2) 90° ELBOWS H 1 V H V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2m) V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H1 = 20´ MAX. (6.2m) Figure 14. Venting with Two 90° Elbows o VENTING WITH TWO (2) 90 ELBOWS V FT. H + H (FT.) 1 1' MIN. (305mm) 5´ MAX. (1.52m) 2' MIN. (610mm) 10´ MAX. (3.1m)

Summary of the content on the page No. 20

VENTING WITH THREE (3) 90° ELBOWS V H H + H 1 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m) V1+V+H+H1 = 40´ MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H1 = 20´MAX.(6.2 m) V 1 V H 1 H V H H + H + H 1 2 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´


Alternative user manuals
# User manual Category Download
1 Heat & Glo LifeStyle 6000 GDVFL User manual Indoor Fireplace 22
2 Heat & Glo LifeStyle 6000 XLT User manual Indoor Fireplace 5
3 Heat & Glo LifeStyle 6000 XLS User manual Indoor Fireplace 10
4 Heat & Glo LifeStyle 6000 ARCH User manual Indoor Fireplace 0
5 Heat & Glo LifeStyle 6000GCF-IPILP User manual Indoor Fireplace 0
6 Heat & Glo LifeStyle 6000GCF-IPI User manual Indoor Fireplace 1
7 Heat & Glo LifeStyle 6000GLX-IPI-S/-R User manual Indoor Fireplace 3
8 Heat & Glo LifeStyle 6000GLX-IPILP-S/-R User manual Indoor Fireplace 1
9 Heat & Glo LifeStyle 6000CL-IPI-T User manual Indoor Fireplace 0
10 Heat & Glo LifeStyle 6000 DVTFL User manual Indoor Fireplace 13
11 Heat & Glo LifeStyle 6000TR-OAK User manual Indoor Fireplace 2
12 Heat & Glo LifeStyle 6000CMOD-IPI User manual Indoor Fireplace 0
13 Heat & Glo LifeStyle 6000CL-IPI-S User manual Indoor Fireplace 0
14 Heat & Glo LifeStyle 6100PLUS User manual Indoor Fireplace 1
15 Heat & Glo LifeStyle 8000CF-OAK-IPI User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1