Heat & Glo LifeStyle 6000GCF-IPI user manual

User manual for the device Heat & Glo LifeStyle 6000GCF-IPI

Device: Heat & Glo LifeStyle 6000GCF-IPI
Category: Indoor Fireplace
Manufacturer: Heat & Glo LifeStyle
Size: 3.45 MB
Added : 7/23/2014
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Heat & Glo LifeStyle 6000GCF-IPI. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Heat & Glo LifeStyle 6000GCF-IPI.

For your convenience

If looking through the Heat & Glo LifeStyle 6000GCF-IPI user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Heat & Glo LifeStyle 6000GCF-IPI on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Heat & Glo LifeStyle 6000GCF-IPI to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Heat & Glo LifeStyle 6000GCF-IPI User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Heat & Glo LifeStyle 6000GCF-IPI but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Heat & Glo LifeStyle 6000GCF-IPI. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Models:
6000GCF-IPI
6000GCF-IPILP
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these
HOT SURFACES!
instructions is not followed exactly, a fi re
Glass and other surfaces are hot during
or explosi

Summary of the content on the page No. 2

Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance This Owner’s Manual should be retained for future —an elegant and clean alternative to wood burning reference. We suggest that you keep it with your other important documents and product manuals. appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, The

Summary of the content on the page No. 3

Table of Contents Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . . . . . . 27 1 Listing and Code Approvals A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 9 Gas Information B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Gas Pre

Summary of the content on the page No. 4

Listing and Code Approvals 1 1 A. Appliance Certifi cation C. BTU Specifi cations Orifi ce Maximum Minimum Models MODELS: 6000GCF-IPI, 6000GCF-IPILP Size Input BTU/h Input BTU/h (U.S. or Canada) (DMS) LABORATORY: Underwriters Laboratories, Inc. (UL) US 30,000 18,200 37 TYPE: Direct Vent Gas Fireplace Heater (0-2000 FT) 6000GCF-IPI STANDARD: ANSI Z21.88b-2005 • CSA 2.33b-2005 CANADA 27,000 16,380 38 (2000-4500 FT) US This product is listed to ANSI standards for “Vented Gas 30,000 18,200

Summary of the content on the page No. 5

Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed G. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall

Summary of the content on the page No. 6

Getting Started 2 2 A. Design and Installation Considerations C. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of WARNING the building and all exhaust gases expelled to the outside. Inspect appliance and components for damage. No additional outside air source is required. Damaged parts may impair safe operation. • Do NOT install damaged components. • Do NOT install incomplete components. CAUTIO

Summary of the content on the page No. 7

Framing and Clearances 3 3 Note: WARNING • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Fire Risk • Illustrations/diagrams are not drawn to scale. Provide adequate clearance: • Actual installation may vary due to individual design • Around air openings preference. • To combustibles • For service access A. Selecting Appliance Location Locate appliance away from traffi c areas. When selecting a location for your appliance it is important to NOTE: For actual

Summary of the content on the page No. 8

insulation. If the appliance is being installed on a cement B. Constructing the Appliance Chase slab, a layer of plywood may be placed underneath to pre- A chase is a vertical boxlike structure built to enclose the vent conducting cold up into the room. gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not re- C. Clearances quired to be, installed inside a chase. Construction of the chase may vary with the type of build- WARNING ing. Th

Summary of the content on the page No. 9

D. Mantel Projections 18 14-1/4 Note: All measurements 10-1/2 in inches. 1 in. MIN. 6-3/4 TOP VIEW 3 3 ft. MAX. MANTEL 11-1/4 LEG 10-1/8 9-1/2 Figure 3.4 Clearances to Mantel Legs or Wall Projections 8-3/8 (Acceptable on both sides of opening.) 7-1/4 NOTE: Measurement is taken from top of the opening, NOT the top of the fi replace. Figure 3.3 Clearances to mantels or other combustibles above appliance Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. F • 6/08 9

Summary of the content on the page No. 10

Termination Locations 4 4 HORIZONTAL A. Vent Termination Minimum Clearances OVERHANG 2 FT. 20 INCHES MIN. VERTICAL MIN. WARNING WALL LOWEST DISCHARGE OPENING Fire Risk. GAS DIRECT VENT Explosion Risk. TERMINATION CAP Inspect external vent cap regularly. X • Ensure no debris blocks cap. 12 • Combustible materials blocking cap may ROOF PITCH ignite. IS X/ 12 • Restricted air fl ow affects burner operation. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING WARNING Roof Pitch H (M

Summary of the content on the page No. 11

M N P R Q (See Note 2) V T S S Electrical V V Service D* V = VENT TERMINAL X V = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inches.................clearances above grade, veranda, L** = 7 ft. ......................... clearance above paved (See Note 1) (See Note 1) porch, deck or balcony sidewalk or a paved driveway located on public property B = 12 inches.................clearances to window or door M*** = 18 inches................ clearance under veranda, porch, that

Summary of the content on the page No. 12

Vent Information and Diagrams 5 5 A. Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams. Symbol Description Vertical First section (closest to appliance) of vertical length V1 Second section of vertical length V2 First section (closest to appliance) of horizontal length H1 8-1/2 in. Second section of horizontal length H2 WARNING Horizontal Fire Hazard. Explosion Risk. Figure 5.1 Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue

Summary of the content on the page No. 13

D. Vent Diagrams WARNING Fire Risk. Explosion Risk. Note: The 6000 series fi replaces can adapt to Do NOT pack insulation or other combustibles SL series vent pipe, if desired. between ceiling fi restops. When venting off the top of the unit, use a DVP-2SL adapter and • ALWAYS maintain specifi ed clearances around a minimum 48 inch vertical section of SL series vent pipe. venting and fi restop systems. After the 48 inch vertical section, the venting table rules • Install wall shield and ceili

Summary of the content on the page No. 14

1. Top Vent - Horizontal Termination - (continued) Three Elbows V Minimum H Maximum V Minimum H Maximum V + V Minimum H + H Maximum 1 1 2 2 1 2 1 2 6 in. 152 mm 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm 1-1/2 ft 457 mm 6 ft 1.8 m 1 ft 305 mm 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm 2 ft 607 mm 6 ft 1.8 m 2 ft 610 mm 6 ft 1.8 m 2 ft 610 mm 6 ft 1.8 m 4 ft 1.4 m 12 ft 3.7 m 3 ft 914 mm 9 ft 2.7 m 3 ft 914 mm 9 ft 2.7 m 6 ft 1.8 m 18 ft 5.5 m H + H = 20 ft (6.1 m) Max. V + V + H + H = 50 ft (15.2

Summary of the content on the page No. 15

2. Top Vent - Vertical Termination V = 50 ft. Max. (15.2 m) 1 No Elbow V = 3 ft. Min. (914mm) 1 NOTE: If installing a vertical vent/ termination off the top of the appli- ance, the fl ue restrictor should be used. See Section 7.D. V 1 Figure 5.6 V H Maximum V V + V Minimum 1 1 2 1 2 Two Elbows 6 in. 152 mm 3 ft 914 mm * * * 1 ft 305 mm 3 ft 914 mm * * * 2 ft 607 mm 6 ft 1.8 m * * * 4 ft 1.2 m 12 ft 3.7 m * * * V1 + V2 + H1 = 50 ft (15.2 m) Max. *No specifi c restrictions on this value EXCEPT V

Summary of the content on the page No. 16

2. Top Vent - Vertical Termination - (continued) V H + H V V + V Minimum H + H Maximum 1 1 2 2 1 2 1 2 Three Elbows 6 in. 152 mm 3 ft 914 mm * * * 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm * * * 3 ft 914 mm 2 ft 610 mm 6 ft 1.8 m * * * 6 ft 1.8 m 4 ft 1.2 m 12 ft 3.7 m * * * 12 ft 3.7 m H + H = 17 ft (5.2 m) Maximum 1 2 V + V + H + H = 50 ft (15.2 m) Maximum 1 2 1 2 V = 6 inches (152 mm) Minimum 1 V 2 H 1 H 2 V 1 INSTALLED HORIZONTALLY Figure 5.8 16 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-

Summary of the content on the page No. 17

Vent Clearances and Framing 6 6 A. Pipe Clearances to Combustibles COMBUSTIBLE SURFACE WARNING 3 IN MIN. (76 mm) Fire Risk. HEAT Explosion Risk. SHIELD Maintain vent clearance to combustibles as specifi ed. • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause fi re. Figure 6.2 3 in. TOP CLEARANCE Fasten the shield in place using the four pilot holes pro- vided in the part. 1 in. CLEARANCE • Position the shie

Summary of the content on the page No. 18

B. Wall Penetration Framing NOTE: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). 12 in. The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be fi eld trimmed. If wall thickness is 10 in. greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required. 3 IN. TOP CLEARANCE HEAT B SHIELD HEAT SHIELD A 1 IN. CLEARANCE BOTTOM SIDES WALL WALL SHIELD FIRESTOP A* B

Summary of the content on the page No. 19

C. Vertical Penetration Framing WARNING Fire Hazard Keep loose materials or blown insulation from touching the ATTIC ABOVE vent pipe. • National building codes recommend using attic shield to keep loose materials/ blown insulation from contacting vent. • Hearth & Home Technologies requires 10 IN. (254 MM) the use of an attic shield. Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/fl oor (see Figure 6.4). • Frame the

Summary of the content on the page No. 20

Appliance Preparation 7 7 Attach previous assembly to the top of the unit using the A. Attaching Sheetrock Ledges provided slots. The face of the sheetrock ledge assembly Attach sheetrock ledges together using the attachment and the unit surround should be fl ush to each other. holes (see Figure 7.1). B. Temporary Access Panel DETAIL A Remove the lower access panel to run the electrical and gas lines to the unit (see Figure 7.3). ATTACHMENT Once the electrical and gas lines are hooked up,


Alternative user manuals
# User manual Category Download
1 Heat & Glo LifeStyle 6000 GDVFL User manual Indoor Fireplace 22
2 Heat & Glo LifeStyle 6000 XLT User manual Indoor Fireplace 5
3 Heat & Glo LifeStyle 6000 XLS User manual Indoor Fireplace 10
4 Heat & Glo LifeStyle 6000 ARCH User manual Indoor Fireplace 0
5 Heat & Glo LifeStyle 6000GCF-IPILP User manual Indoor Fireplace 0
6 Heat & Glo LifeStyle 6000GLX-IPI-S/-R User manual Indoor Fireplace 3
7 Heat & Glo LifeStyle 6000GLX-IPILP-S/-R User manual Indoor Fireplace 1
8 Heat & Glo LifeStyle 6000CL-IPI-T User manual Indoor Fireplace 0
9 Heat & Glo LifeStyle 6000 DVTFL User manual Indoor Fireplace 13
10 Heat & Glo LifeStyle 6000TR-OAK User manual Indoor Fireplace 2
11 Heat & Glo LifeStyle 6000CMOD-IPI User manual Indoor Fireplace 0
12 Heat & Glo LifeStyle 6000TR-OAK-IPI User manual Indoor Fireplace 1
13 Heat & Glo LifeStyle 6000CL-IPI-S User manual Indoor Fireplace 0
14 Heat & Glo LifeStyle 6100PLUS User manual Indoor Fireplace 1
15 Heat & Glo LifeStyle 8000CF-OAK-IPI User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1