Hearth and Home Technologies TIARAI-BR-B user manual

User manual for the device Hearth and Home Technologies TIARAI-BR-B

Device: Hearth and Home Technologies TIARAI-BR-B
Category: Indoor Fireplace
Manufacturer: Hearth and Home Technologies
Size: 6.75 MB
Added : 12/25/2013
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hearth and Home Technologies TIARAI-BR-B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hearth and Home Technologies TIARAI-BR-B.

For your convenience

If looking through the Hearth and Home Technologies TIARAI-BR-B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hearth and Home Technologies TIARAI-BR-B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hearth and Home Technologies TIARAI-BR-B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hearth and Home Technologies TIARAI-BR-B User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hearth and Home Technologies TIARAI-BR-B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hearth and Home Technologies TIARAI-BR-B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DO NOT
DISCARD
Owner’s Manual
Installation and Operation
TIARA I-B
TIARA II-B
Portland
Tested and
O O-T -T L
Listed by Oregon USA
DIRECT VENT ROOM HEATER
US
C
OMNI-Test Laboratories, Inc.
Models:
TIARAI-BK-B TIARAII-BK-B
TIARAI-BR-B TIARAII-BR-B
TIARAI-CTO TIARAII-CTO
TIARAI-CES TIARAII-CES
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating and • Read, understand and
• Leave this manual with
maintenance instructions follow these instructions party responsible for use
for safe install

Summary of the content on the page No. 2

Read this manual before installing or operating this appliance. Please retain this owner's manual for future reference. Congratulations This Owner's Manual should be retained for future reference. Congratulations on selecting a Heat & Glo gas appliance - We suggest that you keep it with your other important an elegant and clean alternative to wood burning appliances. documents and product manuals. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, r

Summary of the content on the page No. 3

- TABLE OF CONTENTS - Section 8: Appliance Setup Section 1: Listing and Code Approvals A. Remove Shipping Materials ................30 A. Appliance Certifi cations ......................4 B. Top to Rear Conversion ......................30 B. Glass Specifi cations ............................4 C. Damper Adjustment ............................31 C. Specifi cations ......................................4 D. Shutter Adjustment .............................32 D. High Altitude Installations .....

Summary of the content on the page No. 4

Listing and Code Approvals 1 C. Specifi cations A. Appliance Certifi cation Maximum Minimum Orifi ce *Steady **P.4 Model Input Input Size State % (US or Canada) BTU BTU Effi ciency MODEL Tiara I B % LABORATORY OMNI-Test Laboratories, Inc. Tiara I B 31,000 22,000 .106 81.43 57.33 061-S-43b-5 (NG) TYPE Vented Gas Fireplace Heater Tiara I B 30,000 23,000 .063 82.75 56.39 (LP) STANDARD ANSI Z21.88-2002 ּ CSA 2.33-2002 Maximum Minimum Orifi ce *Steady **P.4 UL307b ּ CAN/CBA 2.17-M91 Model Input Inp

Summary of the content on the page No. 5

Inspection NOTE: The following requirements reference various The state or local gas inspector of the side wall horizontally Massachusetts and national codes not contained in this vented gas fueled equipment shall not approve the installa- document. tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with G. Requirements for the Commonwealth of the provisions of 248 CMR 5.08(2)(a) 1 through 4. Massachusetts Exemption

Summary of the content on the page No. 6

Getting Started 2 C. Inspect Appliance & Components A. Design & Installation Considerations Heat & Glo direct vent gas appliances are designed to oper- ate with all combustion air drawn from outside of the building WARNING and all exhaust gases expelled to the outside. No additional air source is required. Inspect appliance and components for damage. Damaged parts may impair safe operation. CAUTION • Do NOT install damaged components. • Do NOT install incomplete components. Check building c

Summary of the content on the page No. 7

Appliance Location and Clearances 3 NOTE: WARNING · Illustrations refl ect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: · Illustrations/diagrams are not drawn to scale. • Around air openings · Actual installation may vary due to individual design • To combustibles • For service access preference. Locate appliance away from traffi c areas. A. Selecting Appliance Location When selecting a location for your appliance it is important to WAR

Summary of the content on the page No. 8

C. Clearances to Combustibles - Tiara II-B F C B C E A A "A" measurement is from appliance top, not side H G G A A D 90˚ off top up and out ceiling H Top of Side of Inside Model A B C D E F G pipe pipe Outside corner wall vent Inches Tiara II B 5-1/4 1/4 3/8 54 36 40 31-3/4 1-1/2 1 9 Millimeters 133 6 9.5 1372 914 1016 806 38 25 229 Figure 3.1 For both the Tiara I-B and Tiara II-B, it is permissible to place the appliance on carpet. WARNING Fire Risk. CAUTION Odor Risk. Tip

Summary of the content on the page No. 9

Termination Locations 4 A. Vent Termination Minimum Clearances HORIZONTAL OVERHANG WARNING 2 FT. 20 INCHES MIN. VERTICAL MIN. Fire Risk. WALL LOWEST Explosion Risk. DISCHARGE OPENING Maintain vent clearance to combustibles GAS DIRECT VENT as specifi ed. TERMINATION CAP • Do not pack air space with insulation or X other materials. 12 Failure to keep insulation or other materials away from vent pipe may cause fi re. ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE O

Summary of the content on the page No. 10

M N P G R v A H D Q (See Note 2) E v V B L U.S. B T v (3 FT) v B B v S S Electrical V V Service F v v M I D* v X A J or K V = VENT TERMINAL X = AIR SUPP L Y INLET = ARE A WHERE TERMINA L IS NOT PERMITTED V K = 3 ft. (U.S.A. ) A = 12 inche s ............. clearances above grade , veran- 6 f t. (Canada ) ......... clearance to a mechanical (S ee Not e 1 ) da, porch, deck or balcon y (powered) a i r s uppl y inle t B = 12 inche s ............ clearances to

Summary of the content on the page No. 11

Vent Information 5 A. Venting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only following venting components: CAUTION • Hearth & Home Technologies (HHT) ALL vent confi guration specifi cations MUST be followed. • Simpson Dura-Vent • This product is tested and listed to these specifi cations. • Selkirk Direct-Temp • Appliance performance will suffer if specifi cations are • Amerivent Direct not followed. • Security Secure Vent Diagonal

Summary of the content on the page No. 12

D. How to Use the Vent Graph E. Venting Guidelines NOTE: IF YOUR INSTALLATION FALLS WITHIN A SHADED AREA ON • The maximum horizontal vent run is 20 ft. (6m) when the THE GRAPH, THE DAMPER MUST BE USED.* SEE INFORMATION ON vertical vent rise is 10 ft. (3m). DAMPER ADJUSTMENT ON PAGE 31. *In the Commonwealth of Massachusetts, the word damper shall be replaced • The minimum horizontal vent run is 6 in. (152mm). with the words flue restrictor. • Horizontal sections require a 1/4 in. (6mm) rise

Summary of the content on the page No. 13

F. Horizontal Termination WARNING Fire Hazard. Exhaust Fume Risk. Type A - Up & Out Installation Impaired Performance of Appliance. 90° ELBOW • Ensure vent components are locked together correctly. CENTER LINE • Pipe may separate if not properly joined. TERMINATION CAP PIPE LENGTH WALL THIMBLE/ HEAT SHIELD Step 2. WALL THIMBLE COVER PIPE LENGTH Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a twist-lock ada

Summary of the content on the page No. 14

Step 3. For installations using a round support box/wall thimble (check pipe manufacturer's instructions), mark the wall for a WOOD SCREW 10 in. x 10 in. (254mm x 254mm) square hole. The center of the square hole should line up with the center line of the horizontal pipe, as shown in Figure 5.5. Cut and frame the hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, i.e. masonry block or concrete, a 7 in.

Summary of the content on the page No. 15

VINYL SIDING WARNING Apply sealant to all four sides Fire Hazard. Exhaust Fume Risk. SCREWS Impaired Performance of Appliance. • Ensure vent components are locked together correctly. Bolt horizontal top to vinyl • Pipe may separate if not properly joined. standoff SCREWS WALL THIMBLE COVER WARNING Vinyl siding standoff with siding beneath removed WALL THIMBLE Do NOT connect a pipe section to a termination cap without Figure 5.8 using the telescoping fl ue section found on the termination cap.

Summary of the content on the page No. 16

G. Vertical Termination 1. Direct Vent Pipe VERTICAL TERMINATION CAP STORM COLLAR 35 ft. (11m) MAXIMUM FLASHING FIRESTOP SUPPORT BOX PIPE LENGTH Figure 5.11 Step 2. Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, Figure 5.10

Summary of the content on the page No. 17

Step 3. To install the round support box/wall thimble cover in a flat CAP AND STORM ceiling, cut a 10 in. (254mm) square hole in the ceiling, Shingles overlap on COLLAR NOT SHOWN top edge of flashing centered on the hole drilled in Step 2. Frame the hole as FOR CLARITY shown in Figure 5.13. Ceiling Joists Framing Figure 5.14 Step 7. Continue to assemble pipe sections until the height of the vent (before adding the termination cap) meets the minimum 1 - 1/2 in. (38mm) Long Figure 5.13

Summary of the content on the page No. 18

Step 9. Twist-lock the vent cap and seal. Note: For multi-story vertical installations, a ceiling firestop is required at the second floor, and any subsequent floors (Figure 5.16). The opening should be framed to 10 in. x 10 in. (254mm x 254mm) inside dimensions, in the same manner as shown in Figure 5.13, on the previous page. Nails Ceiling Firestop Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Figure 5.16 WA

Summary of the content on the page No. 19

2. Cathedral Ceiling Step 1. Follow installation Steps 1 and 2 under vertical installation section, page 16. Step 2. Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Cut the hole 1/8 in. (3mm) larger than the support box outline. Step 3. Lower the support box through the hole in the roof until the bottom of the support box protrudes at least 2 in. (51mm) below the ceiling (Figure 5.17). Align the support box both vertically and horizontal

Summary of the content on the page No. 20

Step 4. 3. Class A Metal Chimney Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3mm) diameter holes through the top adapter, and into the chimney top. Ensure that you are TERMINATION CAP drilling into the metal on the chimney. Twist lock the high TOP wind termination cap onto the top adapter (Figures 5.22 ADAPTOR and 5.23). FLASHING EXISTING METAL CHIMNEY SYSTEM 4 in. (102mm) FLEX PIP


Alternative user manuals
# User manual Category Download
1 Hearth and Home Technologies 3100-I User manual Indoor Fireplace 4
2 Hearth and Home Technologies 6000G-IPI User manual Indoor Fireplace 0
3 Hearth and Home Technologies 6000G-LP User manual Indoor Fireplace 0
4 Hearth and Home Technologies 6000G User manual Indoor Fireplace 0
5 Hearth and Home Technologies 6000GBV User manual Indoor Fireplace 0
6 Hearth and Home Technologies 6000G-IPILP User manual Indoor Fireplace 0
7 Hearth and Home Technologies 6000GBV-IPI User manual Indoor Fireplace 1
8 Hearth and Home Technologies 6000 Series User manual Indoor Fireplace 0
9 Hearth and Home Technologies 6000GCF-IPIL User manual Indoor Fireplace 0
10 Hearth and Home Technologies 6000GCF-IPI User manual Indoor Fireplace 0
11 Hearth and Home Technologies 6000GBV-IPILP User manual Indoor Fireplace 0
12 Hearth and Home Technologies 6000GL-IPI-R User manual Indoor Fireplace 0
13 Hearth and Home Technologies 6000GBV-LP User manual Indoor Fireplace 0
14 Hearth and Home Technologies 6000GL-IPI-S User manual Indoor Fireplace 0
15 Hearth and Home Technologies 6000GL-IPILP-S User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1