Hearth and Home Technologies QV36D user manual

User manual for the device Hearth and Home Technologies QV36D

Device: Hearth and Home Technologies QV36D
Category: Indoor Fireplace
Manufacturer: Hearth and Home Technologies
Size: 1.29 MB
Added : 7/26/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hearth and Home Technologies QV36D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hearth and Home Technologies QV36D.

For your convenience

If looking through the Hearth and Home Technologies QV36D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hearth and Home Technologies QV36D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hearth and Home Technologies QV36D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hearth and Home Technologies QV36D User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hearth and Home Technologies QV36D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hearth and Home Technologies QV36D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Model:
Installers Guide
QV36D
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IF THE INFORMATION
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
WARNING: IMPROPER INSTALLA-
ING PROPERTY DAMAGE, PER- TION, ADJUSTMENT, ALTERATION,
SONAL INJURY, OR DEATH. SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
- Do not store or use g

Summary of the content on the page No. 2

SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of ! ! before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !

Summary of the content on the page No. 3

TABLE OF CONTENTS Safety and Warning Information ............................................... 2 u Service Parts List ...................................................................... 4 Section 1: Approvals and Codes .............................................. 6 Appliance Certification ................................................................. 6 Installation Codes ........................................................................ 6 u High Altitude Installations ...........

Summary of the content on the page No. 4

QV36D Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-02 Ending Manufacturing Date: ______ (GN, PL) Vue éclatée des pièces u 5 1 19 3 17 15 16 18 6 2 4 7 Log Set Assembly 14 11 13 8 10 12 9 Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. * 4

Summary of the content on the page No. 5

Service Parts List / Liste des pièces de rechange QV36D IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour

Summary of the content on the page No. 6

Approvals and Codes u High Altitude Installations Appliance Certification U.L. Listed gas appliances are tested and approved without The fireplace model discussed in this Installers Guide has requiring changes for elevations from 0 to 2,000 feet in the been tested to certification standards and listed by the U. S. A. and in Canada. applicable laboratories. When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by Certification changing

Summary of the content on the page No. 7

Getting Started Introducing the Quadra-Fire Gas Fireplace The Hearth & Home Technologies Warranty will be voided Quadra-Fire direct vent gas fireplaces are designed to op- by, and Hearth & Home Technologies disclaims any erate with all combustion air siphoned from outside of the responsibility for, the following actions: building and all exhaust gases expelled to the outside. • Installation of any damaged fireplace or vent system component. The information contained in this Installers Guide, unl

Summary of the content on the page No. 8

28 1/2 [724mm] 14 1/4 [362mm] 21 1/2 [548mm] 8 5/8 [219mm] 11 5/8 [297mm] VENT COLLARS 8 5/8 ELECTRICAL [219mm] ACCESS VENT COLLARS GAS LINE ACCESS 34 5/8 38 25 1/4 [879mm] [965mm] [642mm] 26 7/8 2 1/8 3 1/2 [682mm] [55mm] [90mm] 36 1/8 [916mm] 12 3/4 [323mm] 6 7/8 [174mm] 41 1/8 [1044mm] TOP STANDOFFS HOOD TRIM DOOR RATING PLATE AND LABELS ELECTRICAL GAS LINE ACCESS - ACCESS GAS CONTROLS Figure 1. Diagram of the QV36D 8

Summary of the content on the page No. 9

1” MIN. (25mm) B Installing the Fireplace A Constructing the Fireplace Chase A chase is a vertical box-like structure built to enclose the gas fireplace and/or its vent system. Vertical vents that run on the outside of a building may be, but are not required to be, installed inside a chase. CAUTION: TREATMENT OF FIRESTOP SPACERS AND D E CONSTRUCTION OF THE CHASE MAY VARY WITH THE TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT C SUBSTITUTES FOR THE REQUIREMENTS OF LOCAL BUILDING CODES. THEREFORE, Y

Summary of the content on the page No. 10

Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is CAUTION: MEASURE FIREPLACE DIMENSIONS AND set in place. Framing should be positioned to accommo- VERIFY FRAMING METHODS AND WALL COVERING date wall coverings and fireplace facing material. The dia- DETAILS BEFORE FRAMING. gram below shows framing reference dimensions. Noncombustible zone is defined by 3” above the elbow for the entire width and depth (behind the front header) of the firebox. WALL STUD

Summary of the content on the page No. 11

6 7/16” 6 5/32” (164mm) (156mm) 8 1/2” (216mm) 8 1/2” 11 5/8” (216mm) (295mm) 11 1/16” 7 3/8” 5 7/8” (281mm) (187mm) (149mm) 6 1/2” 5 1/16” (165mm) (129mm) 8 5/8” 8 5/8” (220mm) (220mm) 11 15/16” (303mm) DV-90D DV-48D DV-36D DV17/24D DV-12/17D 12-17 (305-432mm) 17-24 (432-610mm) 35 3/4” (908mm) 47 3/4” (1.2m) 11 3/4” 8 3/4” (298mm) (222mm) 5 3/4” (146mm) DV-09D DV-12D DV-06D NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT. Figure 4. D-Series Direct Vent Component Specifications (5-in

Summary of the content on the page No. 12

Step 3. Installing the Vent System Identifying Vent Components A. Vent System Approvals The vent systems installed on this gas fireplace may in- clude one, two, or three 90° elbow assemblies. The rela- This model is approved to use D-series direct vent pipe tionships of vertical rise to horizontal run in vent configura- components and terminations (see Figures 4 and 5). Ap- tions using 90° elbows MUST BE strictly adhered to. The proved vent system components are labeled for identifica- rise

Summary of the content on the page No. 13

Flue Restrictor Instructions 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see CAP Figure 7). V EXHAUST SHIELD STRAIGHT UP FLUE RESTRICTOR VERTICAL VENTING V (FT.) 40' MAX. (12.4 M) Figure 7 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 8). Figure 6. Straight Up Vertical Venting BREAK HERE NOTE: On vertical venting configurations you may want to install the vertical ba

Summary of the content on the page No. 14

3. Match the amount of vertical you have in the sys- tem with the chart to find the appropriate position HORIZONTAL VENTING to set the Flue Restrictor. Kit No. H Max. Run DVK-01TRD 24" (610 mm) - CHART - Top Vent Top Vent Rear Vent Rear Vent Vertical NG LP NG LP 4' 1 1 1 1 8' 2 2 2 1 15' 2 3 2 2 20' 3 3 3 3 25' 3 3 3 3 30' 3 3 3 3 H 35' 3 3 3 3 90-DEGREE ELBOWS 40' 3 3 3 3 45-DEGREE ELBOW 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Fig- ure 9)

Summary of the content on the page No. 15

VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m) NOTE: On vertical venting configurations where the vertical component is over 10 feet, you may want to install the vertical baffle included in the manual bag assembly to improve flame appearance. Figure 11. Venting with One 90° Elbow o NOT

Summary of the content on the page No. 16

VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2m) V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H = 20´ MAX. (6.2m) 1 Figure 13. Venting with Two 90° Elbows o VENTING WITH TWO (2) 90 ELBOWS V FT. H + H (FT.) 1 H 1' MIN. (305mm) 5´ MAX. (1.52m) 2' MIN. (610mm) 10´ MAX. (3

Summary of the content on the page No. 17

VENTING WITH THREE (3) 90° ELBOWS V H H + H 1 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m) V +V+H+H = 40´ MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H = 20´MAX.(6.2 m) 1 1 1 V H H + H + H 1 2 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.

Summary of the content on the page No. 18

VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 1' MIN. (305mm) 5' MAX. (1.52m) H 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) NOTE: H + H = 20' MAX. (6.2m) 1 V + V + H + H = 40' MAX. (12.4m) 1 1 H1 V1 V V (FT.) H + H (FT.) 1 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H +H = 20' MAX. (6.2m) 1 NOTE: V+V +H +H = 40' MAX. (12.4m

Summary of the content on the page No. 19

B. Installing Vent Components 1. Attach the First Vent Component to Starting Collars After determining which set of starting collars will be used To attach the first vent component to the starting collars (top or rear), follow venting instructions accordingly. of the fireplace: Venting Out the Rear Vent • Apply a 3/8 inch (9.5mm) bead of stove cement around Remove the installed rear seal cap from the rear starting the 5 inch (127mm) fireplace starting collar. collars by cutting the strap at ea

Summary of the content on the page No. 20

2. Fasten the shield in place using the pilot holes provided WARNING: A 3/8 INCH (9.5 MM) BEAD OF ! in the part. The shield should be oriented such that the STOVE CEMENT MUST BE PLACED AROUND 13 1/8 inch dimension (longest dimension) is running in THE 5 INCH (127 MM) FIREPLACE STARTING COL- the same direction the elbow is pointing. The shield should LAR BEFORE ATTACHING THE FIRST VENT COM- be centered directly above the elbow, and positioned so PONENT. FAILURE TO SEAL THIS JOINT MAY that it crea


Alternative user manuals
# User manual Category Download
1 Hearth and Home Technologies 3100-I User manual Indoor Fireplace 4
2 Hearth and Home Technologies 6000G-IPI User manual Indoor Fireplace 0
3 Hearth and Home Technologies 6000G-LP User manual Indoor Fireplace 0
4 Hearth and Home Technologies 6000G User manual Indoor Fireplace 0
5 Hearth and Home Technologies 6000GBV User manual Indoor Fireplace 0
6 Hearth and Home Technologies 6000G-IPILP User manual Indoor Fireplace 0
7 Hearth and Home Technologies 6000GBV-IPI User manual Indoor Fireplace 1
8 Hearth and Home Technologies 6000 Series User manual Indoor Fireplace 0
9 Hearth and Home Technologies 6000GCF-IPIL User manual Indoor Fireplace 0
10 Hearth and Home Technologies 6000GCF-IPI User manual Indoor Fireplace 0
11 Hearth and Home Technologies 6000GBV-IPILP User manual Indoor Fireplace 0
12 Hearth and Home Technologies 6000GL-IPI-R User manual Indoor Fireplace 0
13 Hearth and Home Technologies 6000GBV-LP User manual Indoor Fireplace 0
14 Hearth and Home Technologies 6000GL-IPI-S User manual Indoor Fireplace 0
15 Hearth and Home Technologies 6000GL-IPILP-S User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1