Summary of the content on the page No. 1
CX1000
Complete Air Purification System
Portable Unit
User’s Guide
Read and save these
Instructions
Continental Fan Manufacturing Inc.
Buffalo, NY, U.S.A.
Summary of the content on the page No. 2
TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . .3 Always unplug the CX1000 when it is not in operation, while the filters or UV light are being changed, and when cleaning the unit. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 After servicing the unit, both the front and top grill assemblies must be FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 3
TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . .3 Always unplug the CX1000 when it is not in operation, while the filters or UV light are being changed, and when cleaning the unit. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 After servicing the unit, both the front and top grill assemblies must be FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 4
FEATURES UNPACKING THE CX1000 Before unpacking the unit, inspect the shipping container for visible dam- age. If you feel that you may have received the unit in a damaged condi- Thank you for purchasing the CX1000 Complete Air Purification System. This tion, notify the shipper or supplier before opening the container. Remove unit features unique air purification technologies not found in any other air the unit from the box and inspect it for damage. Handle it carefully. Do purifier. not dro
Summary of the content on the page No. 5
FEATURES UNPACKING THE CX1000 Before unpacking the unit, inspect the shipping container for visible dam- age. If you feel that you may have received the unit in a damaged condi- Thank you for purchasing the CX1000 Complete Air Purification System. This tion, notify the shipper or supplier before opening the container. Remove unit features unique air purification technologies not found in any other air the unit from the box and inspect it for damage. Handle it carefully. Do purifier. not dro
Summary of the content on the page No. 6
SELECT OPERATING MODE SELECT ROOM SIZE Select the desired operating MODE by pressing the SELECT button (figure 3). 1. Determine the area of the room the CX1000 is to purify. AUTO MODE -- This is the mode most com- 2. From the table below, identify the respiratory condition the unit is figure 3 monly used. In AUTO MODE, the Chemical to serve. Sensor (figure 1) controls the blower speed. If the Chemical Sensor detects an unhealthful amount of chemicals present in the air (indi- Heavy Duty Light D
Summary of the content on the page No. 7
SELECT OPERATING MODE SELECT ROOM SIZE Select the desired operating MODE by pressing the SELECT button (figure 3). 1. Determine the area of the room the CX1000 is to purify. AUTO MODE -- This is the mode most com- 2. From the table below, identify the respiratory condition the unit is figure 3 monly used. In AUTO MODE, the Chemical to serve. Sensor (figure 1) controls the blower speed. If the Chemical Sensor detects an unhealthful amount of chemicals present in the air (indi- Heavy Duty Light D
Summary of the content on the page No. 8
SERVICE PANEL INDICATOR LIGHTS PERFORMING MAINTENANCE The SERVICE panel (figure 5) indicates when maintenance is required. Required Maintenance is: Lights on the SERVICE panel indicate if either the UV lamp or the air fil- ters will soon need to be replaced, or if they must be replaced before Replace the UV lamp. (1 year) using the CX1000 again. Replace the filters. (2 years) UV LAMP INDICATOR LIGHTS REPLACING THE UV LAMP The UV lamp has a useful life of one year figure 5 (9,000) hours), wit
Summary of the content on the page No. 9
SERVICE PANEL INDICATOR LIGHTS PERFORMING MAINTENANCE The SERVICE panel (figure 5) indicates when maintenance is required. Required Maintenance is: Lights on the SERVICE panel indicate if either the UV lamp or the air fil- ters will soon need to be replaced, or if they must be replaced before Replace the UV lamp. (1 year) using the CX1000 again. Replace the filters. (2 years) UV LAMP INDICATOR LIGHTS REPLACING THE UV LAMP The UV lamp has a useful life of one year figure 5 (9,000) hours), wit
Summary of the content on the page No. 10
REPLACING THE FILTERS LIMITED LIFETIME WARRANTY figure 8 When the Yellow SERVICE SOON FILTER Each CX1000 Complete Air Purification System comes with a limited life- indicator lights, the filters should be time warranty. This warranty provides for repair or replacement of any replaced within 30 days. defective parts or components for two years from the date of purchase at no charge for labor or materials. This warranty does not cover the 1. Unplug the CX1000 power cord expendable UV lamp, which
Summary of the content on the page No. 11
REPLACING THE FILTERS LIMITED LIFETIME WARRANTY figure 8 When the Yellow SERVICE SOON FILTER Each CX1000 Complete Air Purification System comes with a limited life- indicator lights, the filters should be time warranty. This warranty provides for repair or replacement of any replaced within 30 days. defective parts or components for two years from the date of purchase at no charge for labor or materials. This warranty does not cover the 1. Unplug the CX1000 power cord expendable UV lamp, which
Summary of the content on the page No. 12
Continental Fan Manufacturing Inc. 203 Eggert Road Buffalo, New York 14215 Tel: 800-779-4021 Fax: 716-842-0611 email: cfm@continentalfan.com web: www.continentalfan.com L4-CX1000-UG-0505