Hearth and Home Technologies Cyclone-Cust user manual

User manual for the device Hearth and Home Technologies Cyclone-Cust

Device: Hearth and Home Technologies Cyclone-Cust
Category: Indoor Fireplace
Manufacturer: Hearth and Home Technologies
Size: 2.4 MB
Added : 4/18/2013
Number of pages: 46
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hearth and Home Technologies Cyclone-Cust. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hearth and Home Technologies Cyclone-Cust.

For your convenience

If looking through the Hearth and Home Technologies Cyclone-Cust user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hearth and Home Technologies Cyclone-Cust on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hearth and Home Technologies Cyclone-Cust to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hearth and Home Technologies Cyclone-Cust User manual - Online PDF
Advertisement
« Page 1 of 46 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hearth and Home Technologies Cyclone-Cust but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hearth and Home Technologies Cyclone-Cust. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Model:
Cyclone-Cust
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these
HOT SURFACES!
instructions is not followed exactly, a fi re
Glass and other surfaces are hot during
or explosion may result

Summary of the content on the page No. 2

Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance This Owner’s Manual should be retained for future —an elegant and clean alternative to wood burning reference. We suggest that you keep it with your other important documents and product manuals. appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, The

Summary of the content on the page No. 3

Table of Contents 1 Listing and Code Approvals 9 Gas Information A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. G

Summary of the content on the page No. 4

Listing and Code Approvals 1 1 A. Appliance Certifi cation D. High Altitude Installations U.L. Listed gas appliances are tested and approved with- MODELS: Cyclone-Cust out requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada. LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Fireplace When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating STANDARD: ANSI Z21.50-2000 • CSA2.33-2000 • UL3

Summary of the content on the page No. 5

Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed H. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall

Summary of the content on the page No. 6

Getting Started 2 2 A. Design and Installation Considerations C. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of WARNING the building and all exhaust gases expelled to the out- Inspect appliance and components for damage. side. No additional outside air source is required. Damaged parts may impair safe operation. • Do NOT install damaged components. • Do NOT install incomplete components. CAUTI

Summary of the content on the page No. 7

Framing and Clearances 3 3 Note: WARNING • Illustrations reflect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: • Illustrations/diagrams are not drawn to scale. • Around air openings • Actual installation may vary due to individual design preference. • To combustibles • For service access A. Selecting Appliance Location Locate appliance away from traffi c areas. When selecting a location for your appliance it is important to Note: For actual

Summary of the content on the page No. 8

B. Constructing the Appliance Chase A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not re- quired to be, installed inside a chase. Construction of the chase may vary with the type of build- ing. These instructions are not substitutes for the require- ments of local building codes. Local building codes MUST be checked. Chases should be constructed in the manner of all out-

Summary of the content on the page No. 9

D. Mantel Projections SLIP SECTION FRAMING COMBUSTIBLE MEMBER MATERIAL GLASS FIRESTOP TUBE 34-3/8 in. TO CEILING AND/OR MANTEL TOP 41-3/8 in. OF UNIT (+0 to -1/2 in.) Figure 3.3 Clearances to mantels or other combustibles above appliance Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08 9

Summary of the content on the page No. 10

Termination Locations 4 4 HORIZONTAL A. Vent Termination Minimum Clearances OVERHANG 2 FT. 20 INCHES MIN. VERTICAL MIN. WALL WARNING LOWEST DISCHARGE OPENING Fire Risk. GAS DIRECT VENT TERMINATION CAP Explosion Risk. Inspect external vent cap regularly. X 12 • Ensure no debris blocks cap. • Combustible materials blocking cap may ROOF PITCH IS X/ 12 ignite. H (MIN.) - MINIMUM HEIGHT FROM ROOF • Restricted air fl ow affects burner operation. TO LOWEST DISCHARGE OPENING Roof Pitch H (Min.) Ft

Summary of the content on the page No. 11

M N P R Q (See Note 2) V T S S Electrical V V Service D* V = VENT TERMINAL X V = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inches.................clearances above grade, veranda, L** = 7 ft. ......................... clearance above paved (See Note 1) (See Note 1) porch, deck or balcony sidewalk or a paved driveway located on public property B = 12 inches.................clearances to window or door M*** = 18 inches................ clearance under veranda, porch, that

Summary of the content on the page No. 12

Vent Information and Diagrams 5 5 A. Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams. Symbol Description Vertical First section (closest to appliance) of vertical length V1 Second section of vertical length V2 First section (closest to appliance) of horizontal length H1 8-1/2 in. Second section of horizontal length H2 WARNING Horizontal Fire Hazard. Explosion Risk. Figure 5.1 Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue

Summary of the content on the page No. 13

D. Vent Diagrams WARNING Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • ALWAYS maintain specifi ed clearances around venting and fi restop systems. • Install wall shield and ceiling fi restops as specifi ed. Failure to keep insulation or other material away from vent pipe may cause fi re. 1. Top Vent - Horizontal Termination V Min. H Max. T T One Elbow 2 ft. 2 ft. NOTE: A minimum of 2 feet before 3 ft. 6 ft. the fi rst 90º elbow can be achieved

Summary of the content on the page No. 14

1. Top Vent - Horizontal Termination - (continued) V H V H V Min. H Max. 1 1 2 2 T T Three Elbows **** 2 ft. 2 ft. **** 3 ft. 6 ft. **** 4 ft. 10 ft. **** 5 ft. 15 ft. V + H = 40 ft. Max. T T *No specifi c restrictions on this value EXCEPT V + H cannot exceed 40 ft. Max. T T H T V T V 2 H 2 H 1 V 1 Figure 5.5 14 Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08

Summary of the content on the page No. 15

2. Top Vent - Vertical Termination CAP No Elbow V MAX. T 40 ft. SLIP SECTION Flue Restrictor FLUE Inside Max. Vertical RESTRICTOR Part No. Diameter (V ) T 2061-204 2-3/4 in. 15-30 ft. 2061-203 2-1/2 in. 30 ft. or more V T GLASS CYLINDER ASSEMBLY Drop the fl ue restrictor into the slip section as shown. Figure 5.6 V V V Min. H Max. 1 2 T T Two Elbows * * 2 ft. 2 ft. * * 3 ft. 6 ft. * * 4 ft. 10 ft. * * 5 ft. 15 ft. V + H = 40 ft. Max. T T *No specifi c restrictions on this value EXCEPT V + H ca

Summary of the content on the page No. 16

2. Top Vent - Vertical Termination - (continued) V H H V V Min. H Max. 1 1 2 2 T T Three Elbows **** 2 ft. 2 ft. **** 3 ft. 6 ft. **** 4 ft. 10 ft. **** 5 ft. 15 ft. V + H = 40 ft. Max. T T *No specifi c restrictions on this value EXCEPT V + H cannot exceed 40 ft. Max. T T V T V 2 H T H 2 H 1 V 1 Figure 5.8 16 Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08

Summary of the content on the page No. 17

Vent Clearances and Framing 6 6 A. Pipe Clearances to Combustibles B. Wall Penetration Framing Combustible Wall Penetration WARNING Frame a hole in a combustible wall for an interior wall shield fi restop, (Figure 6.2) whenever a wall is penetrated. Fire Risk. Use same size framing materials as those used in the wall Explosion Risk. construction. The wall shield fi restop maintains minimum Maintain vent clearance to combustibles as clearances and prevents cold air infi ltration. specifi ed.

Summary of the content on the page No. 18

C. Vertical Penetration Framing WARNING Fire Hazard Keep loose materials or blown insulation from touching the ATTIC ABOVE vent pipe. • National building codes recommend using attic shield to keep loose materials/ blown insulation from contacting vent. • Hearth & Home Technologies requires 10 IN. (254 MM) the use of an attic shield. Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/fl oor (see Figure 6.3). • Frame the

Summary of the content on the page No. 19

Appliance Preparation 7 7 A. Securing and Leveling the Appliance SCREW HOLES PROVIDED FOR SECURING WARNING Fire Risk. • Prevent contact with sagging, loose insulation. • Do NOT install against combustible materials such as exposed insulation, plastic and insulation backer. The diagram shows how to properly position, level, and secure the appliance (see Figure 7.1). Holes are provided to secure the appliance to the framing members with screws. • Horizontal venting - refer to Vent Clearan

Summary of the content on the page No. 20

Installing Vent Pipe 8 8 Commercial, Multi-family (Multi-level exceeding two A. Assembly of Vent Sections stories), & High-Rise Applications WARNING For Installation into Commercial, multi-family (multi-level ex- ceeding two stories) or high-rise applications: All pipe joints Do not mix pipe, fi ttings or joining must be sealed with high temperature silicone, including the methods from different manufacturers. slip section that connects directly to the horizontal termina- tion cap, but no


Alternative user manuals
# User manual Category Download
1 Hearth and Home Technologies 3100-I User manual Indoor Fireplace 4
2 Hearth and Home Technologies 6000G-IPI User manual Indoor Fireplace 0
3 Hearth and Home Technologies 6000G-LP User manual Indoor Fireplace 0
4 Hearth and Home Technologies 6000G User manual Indoor Fireplace 0
5 Hearth and Home Technologies 6000GBV User manual Indoor Fireplace 0
6 Hearth and Home Technologies 6000G-IPILP User manual Indoor Fireplace 0
7 Hearth and Home Technologies 6000GBV-IPI User manual Indoor Fireplace 1
8 Hearth and Home Technologies 6000 Series User manual Indoor Fireplace 0
9 Hearth and Home Technologies 6000GCF-IPIL User manual Indoor Fireplace 0
10 Hearth and Home Technologies 6000GCF-IPI User manual Indoor Fireplace 0
11 Hearth and Home Technologies 6000GBV-IPILP User manual Indoor Fireplace 0
12 Hearth and Home Technologies 6000GL-IPI-R User manual Indoor Fireplace 0
13 Hearth and Home Technologies 6000GBV-LP User manual Indoor Fireplace 0
14 Hearth and Home Technologies 6000GL-IPI-S User manual Indoor Fireplace 0
15 Hearth and Home Technologies 6000GL-IPILP-S User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1