Summary of the content on the page No. 1
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
POWER-VENT
HIGH-EFFICIENCY
FIREPLACE WITH
BAY WINDOW
MODELS
PV-28SV50-(BN,BP)-1
PV-28SV55-(CN,CP,GN,GP)-1
™
Installer: Leave this manual with the
appliance.
Consumer: Retain this manual for future
reference.
EFFECTIVE DATE
WARNING: If the information in these in-
NOVEMBER 2006
structions are not followed exactly, a fire or ex-
plosion may result causing property damage,
personal injury or loss of life.
This appliance may be installed in an afte
Summary of the content on the page No. 2
TABLE OF CONTENTS SECTION PAGE Important Safety Information ................................................................................................. 3 Safety Information for Users of LP-Gas ................................................................................. 4 Requirements for Massachusetts ............................................................................................. 5 Gas Supply ...........................................................................
Summary of the content on the page No. 3
IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be lo- • Installation and repair should be done by a QUALI- cated out of traffic and away from furniture and draper- FIED SERVICE PERSON. The appliance should be in- ies. spected before use and at least annually by a qualified service person. More frequent cleaning may be required • Children and adults should be alerted to the hazar
Summary of the content on the page No. 4
SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires and bers of your household. Someday, there may not be a minute to explosions. In its natural state, propane is odorless and colorless. lose, everyone’s safety will depend on knowing exactly what to You may not know all the following safety precautions which can do. If, after reading the following information, you feel you still protect both you and your family from an accident. Read them need more i
Summary of the content on the page No. 5
REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed 3. SIGNAGE. A metal or plastic identification plate shall be in every dwelling, building or structure used in whole or in part permanently mounted to the exterior of the building at a for residential purposes, including those owned or operated by the minimum height of eight (8) feet above grade directly in line Commonwealth and where the side wall exhaust vent termination with the exhaust vent t
Summary of the content on the page No. 6
GAS SUPPLY Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ Installing a New Main Gas Cock CGA-B149 (.1 or .2) installation code. Each appliance should have its own manual gas cock. A manual main gas cock should be located in the vicinity of the Recommended Gas Pipe Diameter unit. Where none exists, or where its size or location is not ad- Pipe Length Schedule 40 Pipe Tubing, Type L equate, contact your local authorized installer for installation or Inside Diameter Outside Diamete
Summary of the content on the page No. 7
INTRODUCTION Introduction Qualified Installing Agency Always consult your local Building Department regarding regu- Installation and replacement of gas piping, gas utilization equip- lations, codes or ordinances which apply to the installation of a ment or accessories and repair and servicing of equipment shall be direct vent wall furnace. performed only by a qualified agency. The term “qualified agen- cy” mean any individual, firm, corporation or company which Instructions to Installer either in
Summary of the content on the page No. 8
SPECIFICATIONS Accessories Model PV28SV50 Input BTU/HR (KW/H) 19,000 Rear - 9,000 Front Part Number Description Height 25 1/8” PV-2H Top Cover - Slim Assembly Width 28 3/16” PV-4H Top Cover - Short Assembly Depth 17 5/8” PVPK Pedestal Kit Gas Inlet (Pipe) 3/8” Flair PVE-1 6” Surround Assembly Electrical - Unit has a 5’ (1.5m) 3 pronged cordset for con- PVSH Rear Shroud nection to an approved 115 VAC 60HZ maximum TRW Wall Thermostat - Wireless Remote AMPs - 5A wall receptacle. FRBTC Battery Ope
Summary of the content on the page No. 9
CLEARANCES FOR DIRECT VENT 1. Pick a location on a wall with a clear space in the room. In The bottom of the exhaust vent terminal and the air intake shall selecting a location for installation, it is necessary to provide be located at least 12” (305mm) above grade and must be vented adequate accessibility clearances for servicing and proper outside. installation. Be sure to locate the unit close enough to a 110 WARNING: The nearest point of the vent cap should be VAC wall receptacle to prop
Summary of the content on the page No. 10
CLEARANCES FOR SINGLE FLUE The bottom of the exhaust vent terminal and the air intake shall 1. Pick a location on a wall with a clear space in the room. In be located at least 12” (305mm) above grade and must be vented selecting a location for installation, it is necessary to provide outside. adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close enough to a 115 WARNING: The nearest point of the vent cap should be a VAC wall receptacle to
Summary of the content on the page No. 11
SPECIFICATIONS Heater with Pedestal and Single Flue Adaptor 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” BSP Connection (Inside) 5 Single Flue Adaptor 28 3/16 ” 17 5/8 ” (71.6cm) (44.8cm) 5 - SINGLE FLUE 33 3/4 ” ADAPT OR (85.7cm) 12 1/4 ” (31.1cm) 8 5/8 ” (21.9cm) 13/16” (2.1cm) 2 - AIR INLET 1 - FLUE OUTLET 1” (2.5cm) 7 9/16 ” 3 - ELECTRIC (19.2cm) CORD 3 9/16 ” 2 13/16 ” (9.0cm) 1 7/16” (7.1cm) (3.7cm) 1 ½ ” (3.8cm) 4 - 3/8” BSP CONNECTION 6 1/8 ” INSIDE (15.6cm) Figure 3
Summary of the content on the page No. 12
SPECIFICATIONS - (continued) Heater without Pedestal 1 Flue Outlet 2 Air Inlet 3 Electric Cord 4 3/8” BSP Connection (Inside) 28 3/16 ” 17 5/8 ” (71.6cm) (44.8cm) 25 1/8 ” (63.8cm) 1 - FLUE OUTLET 3 9/16” (9.0cm) 27 3/4 ” 16 15/16 ” (70.5cm) (43.0cm) 13/16 ” (2.1cm) 2 - AIR INLET 1 - FLUE OUTLET 1” (2.5cm) 7 9/16 ” 3 - ELECTRIC (19.2cm) CORD 3 9/16 ” 2 13/16” (9.0cm) 1 7/16” (7.1cm) (3.7cm) 1 ½ ” (3.8cm) 4 - 3/8” BSP 6 1/8 ” CONNECTION (15.6cm) INSIDE Figure 4 Page 12 22618-4-1106
Summary of the content on the page No. 13
SPECIFICATIONS - (continued) Fireplace Insert with Mantel surround with slim top panel 1 Flue Outlet 2 Electric Cord 3 3/8” BSP Connection (Inside) 4 Surround 35 7/16 ” 5” (12.7cm) (90.0cm) 1 1 5/16 ” (28.7cm) 5 15/16” (15.1cm) 29 3/4 ” (75.6cm) 23 13/16 ” (60.5cm) 1 - FLUE OUTLET 3 9/16 ” (9.0cm) 4 - SURROUND ASSEMBL Y 13/16” (2.1cm) AIR INLET 1 - FLUE OUTLET 1” (2.5cm) 2 - ELECTRIC 7 9/16 ” CORD (19.2cm) 3 9/16 ” 2 13/16” (9.0cm) 1 7/16” (7.1cm) (3.7cm) 1 ½ ” (3.8cm) 3 - 3/8” BSP 6 1/8 ” CONNE
Summary of the content on the page No. 14
SPECIFICATIONS - (continued) Fireplace Insert with Mantel Surround with short top panel 1 Flue Outlet 2 Electric Cord 3 3/8” BSP Connection (Inside) 4 Surround 5 Air Inlet 35 7/16 ” 6 3/16 ” (90.0cm) (15.7cm) 10 1/8 ” (25.7cm) 5 15/16” (15.1cm) 29 3/4 ” (75.6cm) 23 13/16 ” (60.5cm) 1 - FLUE OUTLET 3 9/16” (9.0cm) 16 15/16 ” (43.0cm) 4 - SURROUND ASSEMBL Y 13/16” (2.1cm) 5 - AIR INLET 1 - FLUE 1” OUTLET (2.5cm) 7 9/16 ” 2 - ELECTRIC (19.2cm) CORD 3 9/16 ” 2 13/16 ” (9.0cm) 1 7/16” (7.1cm ) (3.7c
Summary of the content on the page No. 15
CLEARANCE TO COMBUSTIBLES Freestanding Models A B B C C Figure 7 Figure 8 Freestanding Units A Rear Wall to Heater 2” Single Flue and 1 1/4” Direct Vent B Side Wall to Heater 0”/4” recommended for serviceability C Corner Installation 0” D Sidewall to Heater 0” when short top is being used E Mantel Clearance 12” from top of Heater Fireplace Insert CEILING E 12” 40” (30.5cm) (1.0m) W ALL OPENING 29 3/4 ” 26 ½” (75.6cm) (67.3cm) 33 1/4 ” (84.5cm) 35 7/16 ” Figure 10 (90.0cm) Single Flue Requires su
Summary of the content on the page No. 16
LOG SET INSTALLATION INSTRUCTIONS Log Installation All Logs The gas log set (front left log, front right log, center log and rear The positioning of the logs is critical to the safe and clean opera- log) is pre-set and installed in the factory. Only the top left log and tion of this heater. Sooting and other problems may result if the top right log are packaged separately inside the firebox for instal- logs are not properly and firmly positioned in the appliance. lation by the installer. 6. Pri
Summary of the content on the page No. 17
LOG SET INSTALLATION INSTRUCTIONS LOG SET DIAGRAM - A The Gas Log Kit contains the following: 1) Rear Log 2) Center Log 3) Top Right Log 4) Top Left Log 5) Front Left Log 6) Front Right Log 1 - REAR LOG 3 - T O P RIGHT LOG 4 - T O P LEFT LOG 6 - FRONT RIGHT LOG 5 - FRONT LEFT LOG 2 - CENTER LOG Figure 13 22618-4-1106 Page 17
Summary of the content on the page No. 18
INSTALLATION INSTRUCTIONS - GENERAL SAFETY INFORMATION 1. This installation must conform with local codes or, in the ab- sence of local codes with NFPA54. 2. Provide adequate clearances around the product for servic- ing and ensure there are no obstructions to the combustion air intake situated at the back of the heater. Refer to Page 15, Figures 7 and 11. 3. The appliance must be installed on a flat, solid continuous surface (i.e. wood, metal, concrete). Please Note: Rough or uneven surfaces
Summary of the content on the page No. 19
VENT EXAMPLES FOR SINGLE FLUE Max Vent Run - 20ft. Equivalent With Three (3) 90° Elbows Three foot (3’ (91.4cm)) minimum vent run vertical with one (1) 90° elbow The vent terminal 90° elbow and first 90° elbow off back of heater when within 6” (15.2cm) off back of heater do not get count- ed. Special Note: For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18” (45cm). This does not apply if the 45° elbows are installed on the vertical part of
Summary of the content on the page No. 20
VENT EXAMPLES FOR SINGLE FLUE (cont.) VENT CAP (SUPPLIED WITH VENT KIT) H FLASHING H = 16’ V = 1’ (1) - 90° = 3 Total = 20’ 16’ (4.9m) 2 - 4 5 DEG. PVC BENDS (SUPPLIED BY INST ALLER) PVC PIPE (SUPPLIED BY INST ALLER) MANTEL SURROUND FLEXIBLE PVC PIPE 90 ° ELBOW GAS SUPPLY 1’ (30.5cm) Figure 18 Figure 17 Single Flue - Vertical Vent Run Single Flue - Vertical Vent Run with 45 degree elbows Figure 19 Single Flue - Venting with Shroud Installed Page 20 22618-4-1106