Summary of the content on the page No. 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
DV42DX
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
This appliance may be installed
WHAT TO DO IF YOU SMELL GAS
in an after market permanently
• Open windows/extinguish any open flame.
located, manufactured (mobile)
• Do not try to light any appliance. home, where not prohibited by
local codes.
• Do not touch any elect
Summary of the content on the page No. 2
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn
Summary of the content on the page No. 3
Table of Contents Safety Precautions....................................................................................................2 Table of Contents......................................................................................................3 Codes And Approvals................................................................................................4 Specifications...........................................................................................................5 D
Summary of the content on the page No. 4
Codes And Approvals DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed App
Summary of the content on the page No. 5
Specifications INSTALLATION OPTIONS: • Parallel to a wall or placed in a corner • With a floor hearth or raised up the wall • Ducting to other rooms • Vertical or horizontal venting WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. DIMENSIONS: 1 2 / 4 " 2 " ( 5 7m m ) 10 " ( 5 2 m m ) ( 25 4m m ) 3 28 / 1 6 " ( 7 16 m m ) T he cent e r of t he to p ducti n g hoo k- u p
Summary of the content on the page No. 6
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. PILOT LIGHTING INSTRUCTIONS: H o t w h i l e o p er at i ng . D o n o t t o u c h . S e v er e bu r ns m a y r e s u l t. K e ep chi l dr en, C A U T I O N : c l o thi ng, f ur ni t ur e, ga sol i n e or o th er fl a m m abl e va po r s aw a y
Summary of the content on the page No. 7
Room Air Diverter Duct Operating Instructions PILOT LIGHT: 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING. 2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several � � � � � � � � � � � �
Summary of the content on the page No. 8
Operating Instructions BURNER LIGHTING: A) Make sure the pilot is lit. B) Turn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) Turn HI/LO knob to the desired flame height. E) Turn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN GAS FIREPLACE OFF Flip switch to OFF to turn off burners only. If the fireplace is to be turned off for the season, or for Figure 6. Control Panel servicing, turn the gas shut off valve to OFF. DO
Summary of the content on the page No. 9
Maintenance And Service ROUTINE MAINTENANCE: At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips. Warning: Clearances must be sufficient to allow access for maintenance and service Warning: Failure to position the parts in accordance with this manua
Summary of the content on the page No. 10
Maintenance And Service CLEANING DECORATIVE SURFACES: Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft clot
Summary of the content on the page No. 11
Maintenance And Service TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY FUEL CONVERSION: Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qual
Summary of the content on the page No. 12
Initial Installation QUALIFIED INSTALLERS ONLY INTRODUCTION: This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facings, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual. PLACEMENT: The location for the fireplace can be along a wall, raised or at
Summary of the content on the page No. 13
Initial Installation QUALIFIED INSTALLERS ONLY CORNER INSTALLATION: The dimensions for installing a fireplace in the corner of a room are given below in Figure 11. 7 20 / 8 " ( 5 3 0 m m ) 3 46 / 4 " 3 3 1 4 / 4 " 1 4 / 4 " ( 1 18 9m m ) ( 3 7 5m m ) ( 375 m m ) 1 1 9 / 2 " ( 4 9 4m m ) 1 42 " 12 / 16 " ( 1 067m m ) ( 3 07 m m ) 1 66 / 8 " ( 1 6 81 m m ) Figure 11. Dimensions for a corner installation. RAISED FIREPLACES AND HEARTHS: There are a few options with raised fireplaces: raised with no
Summary of the content on the page No. 14
Initial Installation QUALIFIED INSTALLERS ONLY If the unit is raised less than 3” (76mm) it is mandatory to have a hearth installed with P r o t e c t o r p a d , D o n o t t i l e c e m e n t b o a r d a protector pad (sheet metal) h i g h e r t h a n a n d f i n i s h i n g t h i s l e d g e placed directly on the floor or m a t e r i a l . hearth framing, with the cement board (see specs below) on top of it. Tile, or another non- T i l e combustible material forms C e m e n t b o a r
Summary of the content on the page No. 15
Initial Installation QUALIFIED INSTALLERS ONLY MANTEL CLEARANCES: It is not necessary to install a mantel, but if one is desired it is important to follow the guidelines shown in Figure 17. The Manor face has a different set of mantel clearances than the other faces, see Figure 18. C o m b ust i bl e s C om bu s t i bl es 8" ( 203m m ) m a nt el 8 " ( 2 03m m ) m ante l 31⁄2 " ( 89m m ) 20 " ( 5 0 8m m ) 17" 17 " 1 0 " ( 43 2mm ) 1 0 " ( 4 3 2m m ) (2 5 4m m ) ( 2 5 4 m m ) 12 " 12" (305mm )
Summary of the content on the page No. 16
Initial Installation QUALIFIED INSTALLERS ONLY Table 2: Vent termination clearances, refer to Figure 19. 1 2 Letter Canadian Installation US Installation Description A 12 in (30 cm) Clearance above grade, verandah, porch, deck, or balcony. B 12 in (30 cm) 9 in (23 cm) Clearance from window or door that may be opened. C 12 in (30 cm)* Clearance from permanently closed window (to prevent condensation). D 24 in (60 cm)* Vertical clearance to ventilated soffit located above the terminal, within
Summary of the content on the page No. 17
Initial Installation QUALIFIED INSTALLERS ONLY INSTALLATION INSTRUCTIONS: 1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements. 2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjuste
Summary of the content on the page No. 18
Initial Installation QUALIFIED INSTALLERS ONLY through the outside wall far enough to connect onto the vent termination cap. 10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced. 11. Place a bead of high temperature silicone on the intake collar of the fireplace, slid
Summary of the content on the page No. 19
Initial Installation QUALIFIED INSTALLERS ONLY Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent Direct- Secure Vent Ameri Vent Description GS Temp Direct 908 4DT-6 SV4L6 6” pipe length 4D7 7” pipe length 907 4DT-9 9” pipe length 906 4DT-12 SV4L12 4D12 12” pipe length 904 4DT-24 SV4L24 4D2 24” pipe length 903 4DT-36 SV4L36 4D3 36” pipe length 902 4DT-48 SV4L48 4D4 48” pipe length 945 4DT-EL45 SV4EBR45 4D45B 45° elbow, black 990 4DT-EL90 SV4EBR90 4D9
Summary of the content on the page No. 20
Initial Installation QUALIFIED INSTALLERS ONLY VENTING: This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, and MDV SELKIRK METALBESTOS. A 1” (25 mm) clearance to combustibles must be maintained around any vertical vent pipe. Around a horizontal vent pipe, the clearance to combustibles should be 2” (51 mm) above and 11⁄2” (38 mm) on the sides and bottom. When combustible