Enviro ASCOT VENTED GAS FIREPLACE HEATER user manual

User manual for the device Enviro ASCOT VENTED GAS FIREPLACE HEATER

Device: Enviro ASCOT VENTED GAS FIREPLACE HEATER
Category: Indoor Fireplace
Manufacturer: Enviro
Size: 4.12 MB
Added : 5/9/2013
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Enviro ASCOT VENTED GAS FIREPLACE HEATER. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Enviro ASCOT VENTED GAS FIREPLACE HEATER.

For your convenience

If looking through the Enviro ASCOT VENTED GAS FIREPLACE HEATER user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Enviro ASCOT VENTED GAS FIREPLACE HEATER on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Enviro ASCOT VENTED GAS FIREPLACE HEATER to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Enviro ASCOT VENTED GAS FIREPLACE HEATER User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Enviro ASCOT VENTED GAS FIREPLACE HEATER but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Enviro ASCOT VENTED GAS FIREPLACE HEATER. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
ASCOT
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your bu

Summary of the content on the page No. 2

Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn

Summary of the content on the page No. 3

Table of Contents Safety Precautions....................................................................................................2 Table of Contents......................................................................................................3 Codes And Approvals.................................................................................................4 Specifications...........................................................................................................5

Summary of the content on the page No. 4

Codes And Approvals DIRECT VENT ONLY: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. ** TOP VENT DV ONLY** This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated inp

Summary of the content on the page No. 5

Specifications DIMENSIONS: � � � � � � � � � � � � � � � � � � � � � � � � � � � �� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �� 1 Height: 24 /16 inches (611 mm) 1 Width: 19 /16 inches (484 mm) � � � � � � � � � Depth: 15 5⁄8 inches (397 mm) � � � � � � � � � � � � �� � � � � � � �� Center of flue to ground without leveling legs: 18 3⁄8 inches (467 mm) Center of flue to ground with leveling legs (approx.): 19 inches

Summary of the content on the page No. 6

Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. LIGHTING INSTRUCTIONS: H o t w h i l e o p e r a t i n g . D o n o t t o u c h . K e e p c h i l d r e n , c l o t h i n g , C A U T I O N : f u r n i t u r e , g a s o l i n e o r o t h e r f l a m m a b l e v a p o r s a w a y . F O R Y O U R S A F E T Y : D o n o t o p e r a t e t h i s f i r e p l a c e w i t h t h e g l a s s r e m o v e d , c r a c k e d o r b r o k e n . R e p l a c e m e n t o f t h i s g l a s s sh

Summary of the content on the page No. 7

Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating PILOT LIGHT: 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING. 2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob

Summary of the content on the page No. 8

Maintenance And Service ROUTINE MAINTENANCE: At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips. Warning: Clearances must be sufficient to allow access for maintenance and service Warning: Failure to position the parts in accordance with this manua

Summary of the content on the page No. 9

Maintenance And Service REPLACING GLASS: The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see PARTS LIST - COMPONENTS). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacement of

Summary of the content on the page No. 10

Maintenance And Service FUEL CONVERSION: TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result c

Summary of the content on the page No. 11

Maintenance And Service 7. Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 7. 5 b) Insert a /32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 8), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt. L o o s e n T i g h t e n d) Flip the screw (refer to Figure 9). e) Using the Allen wrench as shown in Figure 8, rotate the screw clockwise

Summary of the content on the page No. 12

Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. PREPARATION FOR INSTALLATION: • Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible. • Before beginning, carefully check the glass door and the log set

Summary of the content on the page No. 13

Initial Installation QUALIFIED INSTALLERS ONLY PLANNING YOUR INSTALLATION: When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10 inches (25.4 cm), 11⁄2 inches (3.8 cm) clearance to combustibles must be maintained. Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine the le

Summary of the content on the page No. 14

Initial Installation QUALIFIED INSTALLERS ONLY VENT TERMINATION RESTRICTIONS: N O H D E B C B F i x e d B G C l o s e d L F i x e d O p e n a b l e F Cl o s e d G O p e n a b l e M J K B A I A T e r m i n a t i o n C a p A i r S up p l y I nl e t R e s t r i ct i o n Z on e G G a s M e te r ( Te r m i n a ti o n n ot a l l o w e d ) Figure 15. Vent Termination Restrictions, refer to Table 2. Table 2: Vent termination clearances, refer to Figure 15. 1 2 Letter Canadian Installation US Installati

Summary of the content on the page No. 15

Initial Installation QUALIFIED INSTALLERS ONLY FIREPLACE HORIZONTAL VENT KIT 50-1235: Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury. KIT COMPONENTS: Qnty Description Qnty Description 1 Horizontal direct vent termination cap 4 Wire spacers 1 Flue collar adapter 1 4 oz tube Mill-Pac Sealant 1 Wall thimble 1 4 oz tube RTV silicone 9 1 5’ (190 cm) length of Ø4” (10 cm) double walled fle

Summary of the content on the page No. 16

Initial Installation QUALIFIED INSTALLERS ONLY 10. Apply a bead of Mill-Pac Black sealant to H or i z o ntal V e n t T er m i n a t i on the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced. 11. Place a bead of high temperature silicone on the intake collar of the W a l l Fr am i ng fireplace, slide the Ø65

Summary of the content on the page No. 17

Initial Installation QUALIFIED INSTALLERS ONLY EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance. Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct-Tem

Summary of the content on the page No. 18

Initial Installation VENT RESTRICTOR SETTING: To access restrictor plate, look at the left hand rear corner of the unit. There is a small rectangular hole in the air jacket. Loosen the 1⁄4” hex head bolt and adjust to the correct setting. Slide the hex bolt to the next setting and retighten the bolt to ensure the plate does not move 1 5 ’ ( 4 . 5 7 m ) � � � � � � � � � � � 1 0 ’ ( 3 . 0 5 m ) � � � � � � � � � � � � � � � 1 2 3 4 5 5 ’ ( 1 . 5 2 m ) 1 5 2 3 4 5 � � � � � � � � � 4 � � � � � �

Summary of the content on the page No. 19

Initial Installation QUALIFIED INSTALLERS ONLY HORIZONTAL INSTALLATION: STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented t

Summary of the content on the page No. 20

Initial Installation QUALIFIED INSTALLERS ONLY STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x 10” (25.4 cm) square hole (refer to Figure 22). The center of the square hole should match the center line of the horizontal pipe. Cut and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the exterior wall where the vent will be terminated. Refer to Figure 15. If the wall being penetrated is constructed of non-combustible material i.e. masonry


Alternative user manuals
# User manual Category Download
1 Enviro Ascot 50-029 User manual Indoor Fireplace 0
2 Enviro Ascot User manual Indoor Fireplace 0
3 Enviro DV50DX User manual Indoor Fireplace 0
4 Enviro C-10791 User manual Indoor Fireplace 0
5 Enviro C-11275 User manual Indoor Fireplace 0
6 Enviro DV42DX User manual Indoor Fireplace 1
7 Enviro EG.95.FPI.BV.LPG User manual Indoor Fireplace 0
8 Enviro DV36 User manual Indoor Fireplace 0
9 Enviro EG 28 User manual Indoor Fireplace 0
10 Enviro C-11288 User manual Indoor Fireplace 1
11 Enviro EG 95as User manual Indoor Fireplace 0
12 Enviro EF3 User manual Indoor Fireplace 81
13 Enviro EG-40 User manual Indoor Fireplace 1
14 Enviro EG40 BV User manual Indoor Fireplace 0
15 Enviro User manual Indoor Fireplace 13
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1