Desa Tech CGCFTP user manual

User manual for the device Desa Tech CGCFTP

Device: Desa Tech CGCFTP
Category: Indoor Fireplace
Manufacturer: Desa Tech
Size: 1.83 MB
Added : 1/30/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa Tech CGCFTP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa Tech CGCFTP.

For your convenience

If looking through the Desa Tech CGCFTP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa Tech CGCFTP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa Tech CGCFTP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa Tech CGCFTP User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa Tech CGCFTP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa Tech CGCFTP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

VENT-FREE COMPACT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
For more information, visit www.desatech.com For more information, visit www.desatech.com
CGCFTP
CGCFTN
14,000 to 26,000 Btu/Hr
with Thermostat
Shown with Optional
Cabinet Mantel/Hearth
Base Accessory
WARNING: Improper installation, adjust-
WARNING: If the information in this manual is not
ment, alteration, service, or maintenance
followed exactly, a fire or explosion may result
can cause injury or property damage.
causing pro

Summary of the content on the page No. 2

TABLE OF CONTENTS SAFETY INFORMATION 2 TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 TROUBLESHOOTING .............................................................. 20 LOCAL CODES ........................................................................... 3 SPECIFICATIONS .................................................................... 23 PRODUCT IDENTIFICATION ..................................................... 3 REPLACEMENT PARTS .....

Summary of the content on the page No. 3

SAFETY INFORMATION 3 LOCAL CODES 3 PRODUCT IDENTIFICATION SAFETY INFORMATION Continued 1. This appliance is only for use with the type of gas indicated on 16. Operating fireplace above elevations of 4,500 feet could cause the rating plate. This appliance is not convertible for use with pilot outage. other gases. 17. Do not operate fireplace if any log is broken. Do not operate 2. Do not place propane/LP supply tank(s) inside any structure. Lo- fireplace if a log is chipped (dime-sized or larger)

Summary of the content on the page No. 4

PRODUCT FEATURES 4 UNPACKING ASSEMBLY Assembling Fireplace PRODUCT FEATURES ASSEMBLY SAFETY PILOT WARNING: Always have branch support and This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) screen in place before operating fireplace. This pre- safety shutoff system. The ODS/pilot is a required feature for vent- vents excessive temperatures on fireplace surfaces. free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air. WARNING: Failure to posit

Summary of the content on the page No. 5

ASSEMBLY 5 Assembling Fireplace (Cont.) 5 AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation ASSEMBLY Continued While it is good to make your home energy efficient, your home Assembling Hood needs to breathe. Fresh air must enter your home. All fuel-burning 1. Locate four black phillips sheet metal screws from the hard- appliances need fresh air for proper combustion and ventilation. ware packet. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances 2. Rotate hood

Summary of the content on the page No. 6

AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation (Cont.) 6 Determining Fresh-Air Flow for Heater Location AIR FOR COMBUSTION AND VENTILATION Continued 3. Add the Btu/Hr of all fuel burning appliances in the space. Confined and Unconfined Space Vent-free heater _____________ Btu/Hr The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a Gas water heater* _____________ Btu/Hr confined space as a space whose volume is less than 50 cubic feet 3 Gas furnace _____________ Btu/Hr per

Summary of the content on the page No. 7

AIR FOR COMBUSTION AND VENTILATION 7 Ventilation Air 7 INSTALLATION Check Gas Type AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilated Ventilation Air From Inside Building Outlet Attic Air This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must Outlet provide two permanent openings: one within 12" of the ceiling and Air To Attic one within 12" of the floor on the wall connecting the two spaces (see options 1 a

Summary of the content on the page No. 8

INSTALLATION Installation Items 8 Locating Fireplace INSTALLATION Continued IMPORTANT: Vent-free fireplaces add moisture to the air. Although INSTALLATION ITEMS this is beneficial, installing fireplace in rooms without enough venti- Before installing fireplace, make sure you have the items listed below. lation air may cause mildew to form from too much moisture. See Air • external regulator - propane/LP only (supplied by installer) for Combustion and Ventilation, pages 5 through 7. • piping (che

Summary of the content on the page No. 9

INSTALLATION 9 Locating Fireplace (Cont.) 9 Built-In Fireplace Installation INSTALLATION Continued For convenience and efficiency, install fireplace 3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after • where there is easy access for operation, inspection, and service. the equipment shutoff valve. The flexible gas line must be the • in coldest part of room last item installed on the gas piping. An optional blower

Summary of the content on the page No. 10

INSTALLATION Built-In Fireplace Installation (Cont.) 10 Mantel Clearances for Built-In Installation Optional Mantel Installation INSTALLATION Continued Mantel Shelf 10" WARNING: Do not allow any combustible materi- Note: als to overlap the firebox front facing. 8" All vertical Note: All vertical measurements 6" measurements are IMPORTANT: Noncombustible materials such as brick, tile, etc. are from top of from top of fireplace 1 2 /2" may overlap the front facing, but should never cover any nece

Summary of the content on the page No. 11

INSTALLATIONS 11 11 Optional Mantel Installation (Cont.) Assembling Brass Trim Installing Blower Accessory - GA3450T INSTALLATION Continued 6. Align brass trim kit for flush fit around opening. Slot Set Screws 7. Use two 3" wood screws provided and attach fireplace base to Top Brass Trim wooden base (see Figure 13, page 10). 8. Remove brass trim kit and mantel. Be careful not to damage Mitered Edge wall or mantel. Shim Side Brass Trim 9. Place wood base next to wall at installation location. Adj

Summary of the content on the page No. 12

3 2 1 INSTALLATION Installing Blower Accessory - GA3450T (Cont.) 12 INSTALLATION Continued 3. Note the wire locations on back of AUTO/OFF/ON switch. Removing Valve Cover Shield The terminals on back of switch are numbered 1, 2, and 3. 1. Open bottom louver assembly by swinging the assembly down Carefully remove red wire from terminal 1 and blue wire from (see Figure 17). terminal 3. Black wire can remain on middle terminal 2 (see 2. Using short Phillips screwdriver, remove the screw under the Fi

Summary of the content on the page No. 13

3 2 1 INSTALLATION 13 Installing Blower Accessory - GA3450T (Cont.) 13 INSTALLATION Continued 9. Install the switch plate on the valve cover shield with 2 #10 5. Plug power cord to the outlet receptacle (not provided) as shown screws provided (see Figure 19). Reinstall the valve cover in Figure 21. Wind the extra cable in power cord and and tie it up shield. Route power cord out of the cabinet by inserting it with the plastic wire strap (see Figure 21). Set the cable bundle through the bushing o

Summary of the content on the page No. 14

INSTALLATION Installing Blower Accessory - GA3450T (Cont.) 14 Attaching Wood Base to Solid Floor Connecting to Gas Supply INSTALLATION Continued For propane/LP units, installer must supply an external regulator. Extension Cord The external regulator will reduce incoming gas pressure. You must Use extension cord if needed. The cord must have a three-prong, reduce incoming gas pressure to between 11 and 14 inches of water. grounding plug and a three-hole receptacle. Make sure cord is in good If yo

Summary of the content on the page No. 15

INSTALLATION 15 Connecting to Gas Supply (Cont.) 15 Connecting Equipment Shutoff Valve to Heater Control INSTALLATION Continued We recommend that you install a sediment trap in supply line as CAUTION: Avoid damage to regulator. Hold gas shown in Figure 24. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. regulator with wrench when connecting it to gas piping and/or fittings. Locate sediment trap where trapped matter is not l

Summary of the content on the page No. 16

INSTALLATION 16 Checking Gas Connections INSTALLATION Continued CHECKING GAS CONNECTIONS Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 27). WARNING: Test all gas piping and connections, 2. Open main gas valve located on or near gas meter for natural internal and external to unit, for leaks after installing gas or open propane/LP supply tank valve. or servicing. Correct all leaks at once. 3. Make sure control knob of fireplace is in the OFF position. 4. C

Summary of the content on the page No. 17

OPERATING FIREPLACE 17 For Your Safety Read Before Lighting 17 Lighting Instructions OPERATING FIREPLACE 5. Turn control knob counterclockwise to the PI- FOR YOUR SAFETY LOT position. Press in control knob for five (5) seconds READ BEFORE LIGHTING (see Figure 30). Note: You may be running this fireplace for the first time WARNING: If you do not follow these instructions after hooking up to gas supply. If so, the control knob may exactly, a fire or explosion may result causing prop- need to be

Summary of the content on the page No. 18

OPERATING FIREPLACE To Turn Off Gas To Appliance 18 Thermostat Control Operation Manual Lighting Procedure INSPECTING BURNER Pilot Flame Pattern Burner Flame Pattern OPERATING FIREPLACE INSPECTING BURNER Continued Check pilot flame pattern and burner flame pattern often. TO TURN OFF GAS PILOT FLAME PATTERN TO APPLIANCE Figure 32 shows a correct pilot flame pattern. Figure 33 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly Shutting Off Fireplace heating the therm

Summary of the content on the page No. 19

CLEANING AND MAINTENANCE 19 Cleaning Burner Injector Holder and Pilot Air Inlet Hole 19 Cabinet CLEANING AND MAINTENANCE Clean the pilot assembly also. A yellow tip on the pilot flame WARNING: Turn off fireplace and let cool before indicates dust and dirt in the pilot assembly. There is a small pilot cleaning. air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 37). With the unit off, lightly blow air through the air inlet hole. You may blow th

Summary of the content on the page No. 20

TROUBLESHOOTING 20 TROUBLESHOOTING Note: For additional help, visit DESA WARNING: Turn off and un- CAUTION: Never use a wire, Heating Products’ technical service web plug fireplace and let cool before needle, or similar object to clean site at www.desatech.com. servicing. Only a qualified ser- ODS/pilot. This can damage ODS/ Note: All troubleshooting items are listed in vice person should service and pilot unit. order of operation. repair fireplace. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When i


Alternative user manuals
# User manual Category Download
1 Desa Tech CGF265NVA User manual Indoor Fireplace 0
2 Desa Tech CGD3930PT User manual Indoor Fireplace 0
3 Desa Tech CGD3930P User manual Indoor Fireplace 0
4 Desa Tech CGD3924PT User manual Indoor Fireplace 0
5 Desa Tech CGFB32C User manual Indoor Fireplace 1
6 Desa Tech CGD3924P User manual Indoor Fireplace 0
7 Desa Tech CGD3018P User manual Indoor Fireplace 0
8 Desa Tech CGF280NT User manual Indoor Fireplace 0
9 Desa Tech CGN10T User manual Indoor Fireplace 0
10 Desa Tech CGN10TL User manual Indoor Fireplace 0
11 Desa Tech CGFB32NC User manual Indoor Fireplace 0
12 Desa Tech CHDV34PA User manual Indoor Fireplace 0
13 Desa Tech CHDV34NA, CHDV34PA User manual Indoor Fireplace 0
14 Desa Tech CHDV37P User manual Indoor Fireplace 0
15 Desa Tech CHDV37N User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1