Desa VMH26PR user manual

User manual for the device Desa VMH26PR

Device: Desa VMH26PR
Category: Indoor Fireplace
Manufacturer: Desa
Size: 0.85 MB
Added : 1/3/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa VMH26PR. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa VMH26PR.

For your convenience

If looking through the Desa VMH26PR user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa VMH26PR on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa VMH26PR to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa VMH26PR User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa VMH26PR but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa VMH26PR. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
VENT-FREE PROPANE/LP GAS
®
COMPACT CLASSIC HEARTH FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
VMH26PR
15,000 to 26,000 Btu/Hr
Shown with Optional
Remote Control Ready
Cabinet Mantel/Hearth
Base Accessory
WARNING: Improper installation,
WARNING: If the information in this manual is not
adjustment, alteration, service, or
followed exactly, a fire or explosion may result caus-
maintenance can cause injury or
ing property damage, personal injury, or loss of life.
property damage. Refer to

Summary of the content on the page No. 2

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE 3. If you smell gas these products may create a white pow- SAFETY • shut off gas supply der residue within burner box or on INFORMATION • do not try to light any appliance adjacent walls or furniture. • do not touch any electrical switch; 13. This fireplace needs fresh air ventila- WARNINGS do not use any phone in your building WARNING ICON G 001 tion to run properly. This fireplace has • immediately call your gas supplier an oxygen depletion sensor (O

Summary of the content on the page No. 3

HI TEMP MAN LO ON AUTO OFF STATUS OWNER’S MANUAL PRODUCT PRODUCT IDENTIFICATION FEATURES Fireplace Cabinet SAFETY PILOT This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air. Screen PIEZO IGNITION SYSTEM This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace. Logs REMOTE

Summary of the content on the page No. 4

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE Screen Back Log ASSEMBLY Shipping Screw Shoulder Screw WARNING: Always have branch support and screen in place before operating fireplace. This prevents excessive tempera- tures on fireplace surfaces. Burner Support Screw WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in prop- erty damage or personal injury ASSEMBLING FIREPLACE Branch Support To

Summary of the content on the page No. 5

OWNER’S MANUAL Confined and Unconfined Space PROVIDING ADEQUATE AIR FOR VENTILATION The National Fuel Gas Code (ANS Z223.1, COMBUSTION AND 1992 Section 5.3) defines a confined space The following are excerpts from National VENTILATION as a space whose volume is less than 50 Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- 3 cubic feet per 1,000 Btu per hour (4.8 m per tion 5.3, Air for Combustion and Ventilation. kw) of the aggregate input rating of all WARNING: This heater shall All spaces in homes fal

Summary of the content on the page No. 6

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width

Summary of the content on the page No. 7

OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION 12" Continued VENTILATION AIR Ventilation Grills Into Adjoining Room, Ventilation Air From Inside Ventilation Option 2 Grills Or Building into Adjoining Remove Room, Door into This fresh air would come from an adjoining Option 1 Adjoining Room, unconfined space. When ventilating to an Option 3 adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall conn

Summary of the content on the page No. 8

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE Note: Your Vanguard fireplace is designed INSTALLATION to be used in zero clearance installations. CAUTION: If you install the fireplace in a home garage Wall or framing material can be placed NOTICE: This heater is intended • fireplace pilot and burner must directly against any exterior surface of for use as supplemental heat. Use be at least 18 inches above your fireplace, except where standoff spac- this heater along with your pri- ers are integrally

Summary of the content on the page No. 9

OWNER’S MANUAL 2. If installing GA3400(T) blower acces- 5. Carefully set fireplace in front of rough INSTALLATION sory, do so at this time. Follow instruc- opening with back of fireplace inside Continued tions included with blower accessory. wall opening. BUILT-IN FIREPLACE Note: If not installing blower acces- 6. Attach flexible gas line to fireplace gas sory, you may wish to run electrical regulator. See Connecting Fireplace to INSTALLATION wiring to your fireplace for future Gas Supply, page

Summary of the content on the page No. 10

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE 3 1 /4" Screw 12. Check for leaks. See Checking Gas INSTALLATION Connections, page 15. Continued 13. Place mantel around fireplace. Be care- Mantel Clearances for Built-In ful not to damage wall or mantel. Wood Installation 14. Place brass trim kit on the shoulder Base screws located on the side and top of If placing mantel above built-in fireplace, the fireplace. Firmly snap the brass trim you must meet minimum clearance between Figure 13 - Attaching

Summary of the content on the page No. 11

3 2 1 OWNER’S MANUAL 4. Carefully disconnect green and white Installing Blower Assembly INSTALLATION wires at their insulated connectors. Note: If you are using a mantel with your Continued 5. In top of the heater cabinet, locate the heater, use the following instructions. If four mounting holes on the outer cas- INSTALLING BLOWER your heater is built-in, see For Built-In In- ing. Align these four holes with those stallation on page 12. ACCESSORY GA3400T on the blower bracket assembly. Attach 1.

Summary of the content on the page No. 12

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE 4. Plug power cord to the outlet receptacle For Built-In Installation INSTALLATION (not provided) as shown in figure 19. Continued Wind the extra cable in power cord and WARNING: A licensed electri- and tie it up with the plastic wire strap 9. Install the switch plate on the valve cian must connect the wiring har- (see Figure 19). Set the cable bundle cover shield with 2 #10 screws provided ness to electrical supply follow- between the burner bracket a

Summary of the content on the page No. 13

OWNER’S MANUAL The installer must supply an external regu- Installation must include a manual shutoff INSTALLATION lator. The external regulator will reduce valve, union, and plugged 1/8" NPT tap. Continued incoming gas pressure. You must reduce Locate NPT tap within reach for test gauge incoming gas pressure to between 11 and hook up. NPT tap must be upstream from Extension Cord 14 inches of water. If you do not reduce fireplace (see Figure 23). Use extension cord if needed. The cord must incom

Summary of the content on the page No. 14

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE INSTALLATION Screen Continued Shipping Screw CONNECTING FIREPLACE TO GAS SUPPLY Shoulder Installation Items Needed Screw • Phillips screwdriver • sealant (resistant to propane/LP gas, not provided) 1. Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are Screen located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove. 2. Remove screws that attach branch sup- Branc

Summary of the content on the page No. 15

OWNER’S MANUAL Test Pressures Equal To or Less Than Pressure Testing Fireplace Gas INSTALLATION 1/2 PSIG Connections Continued 1. Close manual shutoff valve (see Fig- 1. Open manual shutoff valve (see ure 26). Figure 26). CHECKING GAS 2. Pressurize supply piping system by ei- 2. Open propane/LP supply tank valve. CONNECTIONS ther using compressed air or opening 3. Make sure control knob of fireplace is propane/LP supply tank valve. in the OFF position. WARNING: Test all gas pip- 3. Check all j

Summary of the content on the page No. 16

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE OPTIONAL WALL MOUNTED INSTALLATION THERMOSTAT - GWMT1 Continued Remote OPTIONAL WIRELESS HAND- WARNING: Read and follow Receiver HELD REMOTE CONTROL installation instructions. Instal- Black Wire ACCESSORIES lation should be done by a quali- Red Wire fied installer familiar with low- (GHRC Series & GHRCT Series) voltage wiring procedures. Wire Harness* Installing Receiver 1. Remove screws. WARNING: Do not connect 2. Disconnect switch wires from the con

Summary of the content on the page No. 17

AUTO ON OFF OWNER’S MANUAL OPTIONAL WALL SWITCH - INSTALLATION GWMS2 Continued Terminal "W" W 6. Connect one bare wire end to each ter- WARNING: Read and follow minal (“W” and “R”) of the thermostat installation instructions. Instal- base (see Figure 34). lation should be done by a quali- fied installer familiar with low- 7. Install the base onto the wall with the voltage wiring procedures. provided screws. 8. Move the temperature adjustment back and forth to insure the bimetal is free WARNING

Summary of the content on the page No. 18

N O T ® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE 7. With control knob pressed in, press LIGHTING OPERATING and release ignitor button. This will INSTRUCTIONS light pilot. The pilot is attached to the FIREPLACE front burner. If needed, keep press- WARNING: You must operate ing ignitor button until pilot lights. FOR YOUR SAFETY this fireplace with the fireplace Note: If pilot does not stay lit, con- READ BEFORE screen in place. Make sure fire- tact a qualified service person or gas LIGHTING place

Summary of the content on the page No. 19

O F F O OWNER’S MANUAL IMPORTANT: Do not leave the se- OPTIONAL REMOTE OPERATING lector switch in the REMOTE posi- OPERATION FIREPLACE tion when the pilot is not lit. This will drain the battery. Note: All remote control accessories must Continued be purchased separately (see Accessories, IMPORTANT: Be sure to press the Pilot Burner pages 26 and 27). Follow installation in- ON/OFF buttons on the hand held Ignitor structions on page 16 of this manual. remote control unit for up to 3 sec- Electrod

Summary of the content on the page No. 20

® VMH26PR COMPACT CLASSIC HEARTH FIREPLACE GWMT1 WALL OPERATING OPERATING BLOWER MOUNTED FIREPLACE This blower has three settings: ON, OFF, THERMOSTAT Continued and AUTO. In the ON position, the blower (OPTIONAL) will operate constantly. In the OFF posi- tion, the blower will not operate. In the IMPORTANT: The hand-held remote Make sure the heater switch is on AUTO AUTO position, the blower will start when control unit must be near the heater. and set the temperature adjustment on the thermostat


Alternative user manuals
# User manual Category Download
1 Desa (V)368ST User manual Indoor Fireplace 0
2 Desa (V)B36L User manual Indoor Fireplace 0
3 Desa (V)C36 User manual Indoor Fireplace 0
4 Desa (V)C36H User manual Indoor Fireplace 1
5 Desa (V)B36LI User manual Indoor Fireplace 0
6 Desa (V)C36I User manual Indoor Fireplace 1
7 Desa (V)B36I User manual Indoor Fireplace 1
8 Desa (V)C36L User manual Indoor Fireplace 0
9 Desa (V)B36 User manual Indoor Fireplace 4
10 Desa (V)C36LH User manual Indoor Fireplace 0
11 Desa (V)C36LI User manual Indoor Fireplace 0
12 Desa (V)CB36N(E) User manual Indoor Fireplace 0
13 Desa (V)CB36P(E) User manual Indoor Fireplace 0
14 Desa (V)DVF36 User manual Indoor Fireplace 2
15 Desa (V)G36 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1