Desa VM36P(B,H) user manual

User manual for the device Desa VM36P(B,H)

Device: Desa VM36P(B,H)
Category: Indoor Fireplace
Manufacturer: Desa
Size: 2.94 MB
Added : 1/3/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa VM36P(B,H). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa VM36P(B,H).

For your convenience

If looking through the Desa VM36P(B,H) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa VM36P(B,H) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa VM36P(B,H) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa VM36P(B,H) User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa VM36P(B,H) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa VM36P(B,H). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

-V b eNt deCoratIVe Gas FIrePla Ce
oWNer’s oPeratIoN aNd INstallatIoN maNal u
o-tl rePort # 114-F-16-4
Natural Gas models
m36(b,h), m42(b,h), Vm36(b ,h)
aNd Vm42(b ,h)
ProP aNe/lP Gas models
m36P(b,h), m42P(b,h),
Vm36P(b ,h) aNd Vm42P(b ,h)
W ARNING: If the information in these instructions
is not follow ed exactly , a fire or explosion may result
causing property damage, personal injury or death.
FOR YOUR SAFETY
— Do not store or use gasoline or any other flamma

Summary of the content on the page No. 2

W ARNING: Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in- stallation and operational procedures. For assistance or additional information consult a qualified installer , service agency or the gas supplier. NOT FOR USE WITH SOLID FUEL CHECK LOCAL CODES PRIOR TO INSTALLATION SAVE THIS BOOK This book is valuable. In addition to instructing you on how to ins

Summary of the content on the page No. 3

saFety 1. This appliance is only for use with the type WARNING: This product con- of gas indicated on the rating plate. This appliance is not convertible for use with tain s an d/o r generates ch emicals other gases unless a certified kit is used. known to the State of California 2. For propane/LP fireplace, do not place to cause cancer or birth defects propane/LP supply tank(s) inside any or other reproductive harm. structure. Locate propane/LP supply tank(s) outdoors.

Summary of the content on the page No. 4

saFety Continued 11. Keep the area around your fireplace adequate clearances around air open- clear of combustible materials, gasoline ings into the combustion chamber along and other flammable vapor and liquids. with adequate accessibility clearance for Do not run fireplace where these are servicing and proper operation. used or stored. Do not place items such 16. Do not install fireplace directly on carpet- as clothing or decorations on or around ing, vinyl tile or any combustible material

Summary of the content on the page No. 5

INtroduCtIoN Continued The installation must conform with local codes or, in the absence of local codes, with the cur- CAUTION: Do not connect rent National Fuel Gas Code, ANSI Z223.1/ appliance before pressure test- NFPA 54. This appliance complies with ANSI ing gas piping. Damage to gas Z21.50/CSA 2.22. valve may result and an unsafe condition may be caused. WARNING: Installation of this appliance should be done The appliance and it’s individual shutoff valve must be

Summary of the content on the page No. 6

ProduCt sPeCIFICatIoNs GAS RATING - NATURAL M36(B,H), VM36(B,H) M42(B,H), VM42(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5" WC (.87 kPa) 3.5" WC (.87 kPa) Minimum Supply Pressure: 4.5" WC (1.12 kPa) 4.5" WC (1.12 kPa) Maximum Supply Pressure: 10.5" WC (2.66 kPa) 10.5" WC (2.66 kPa) Orifice Size: # 30 # 29 GAS RATING - PROPANE/LP M36P(B,H), VM36P(B,H) M42P(B,H), VM42P(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 10" WC (2.49 kPa) 10" WC (2.

Summary of the content on the page No. 7

Pre-INstallatIoN PreP aratIoN CLEARANCES MANTEL CLEARANCES AND WALL Minimum clearances to combustibles are: DETAILS Back and Sides of Outer Surround 0" min. A combustible mantle shelf maybe installed a maximum 12" (22.9 cm) from the wall. Drywall to Sides of Front Face Figures 5 and 6 show the minimum allow- (Nailing Flanges) 0" min. able distances from various combustible “B” Vent Surfaces 1" min. mantle components in relation to fireplace Ceiling to Opening 42" min. opening. Floor 0"

Summary of the content on the page No. 8

Pre-INstallatIoN PreP aratIoN Continued FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. 2. Place the appliance into the framing and A secure it. B Note: If appliance is to be raised above floor level, a platform must be built to C support the appliance. 3. Install the supply line to the appliance M36(B,H), M42(B,H), using a 1/2" NPT black iron

Summary of the content on the page No. 9

Pre-INstallatIoN PreP aratIoN Continued B-Vent Piping INSTALLING TRANSITION PIPE AND STARTER COLLAR The transition pipe and starter collar shown Starter Collar in Figure 9 are supplied with the fireplace, unattached and ready for installation. Re- move starter collar and set aside. Slide Transition Pipe transition pipe over vent collar and attach with a minimum of three screws. Replace starter collar over transition pipe and attach Vent Collar using four screws located on leg stands (five

Summary of the content on the page No. 10

VeNtING INstallatIoN Continued Listed Vent Cap Listed Listed Vent Cap Vent Cap Maintain Maintain Listed Listed Clearance Clearance Maintain Maintain Listed Support Each Clearance Lateral At Listed Least Every Clearance 45° 60° 6 Feet 12' Min. 45° 8' Position 10' Position 6' Firestop Firestop Position 12' Min. 12' Min. 45° Firestop Maintain Maintain Maintain Listed Listed Listed Clearance Clearance Clearance EXAMPLE 1 EXAMPLE 2 EXAMPLE 3 Figure 10 - Typical B-Vent Configuration Some codes areas a

Summary of the content on the page No. 11

VeNtING INstallatIoN Continued CHECKING FOR PROPER VENTING NOTICE: This appliance is After completing and checking electrical, e q u i p p e d w i t h a v e n t s a f e t y gas and vent connections, follow the lighting shutoff switch which will shut instructions and allow main burner to run down the appliance in the case for approximately 5 minutes. Hold a lighted of a venting problem. Do not match or cigarette near the top edge of fire- place opening and play it

Summary of the content on the page No. 12

O IN OUT INstallatIoN Continued 4. Connect wires to control circuit. Connect OPTIONAL WIRELESS HAND-HELD white wire to terminal marked TH/TP on REMOTE CONTROL INSTALLATION control valve. Connect red wire to male Note: If using optional wireless hand-held blade connector provided at open end of remote control, the wall switch is no longer safety circuit wiring (see Wiring Diagram, operational. page 22). Installing Receiver 5. Locate battery clip mounted on back of 1. Remove front refr

Summary of the content on the page No. 13

INstallatIoN Continued Installing 9-Volt Battery in Hand-Held DESA Heating, LLC recommends that a black Remote Control Unit iron gas line be routed from the gas source, 1. Remove battery cover on back of remote through a sediment trap (see Figure 20) and control unit. into appliance. Once connected through ap- pliance, a flexible gas line may be used for 2. Attach terminal wires to battery (not ease of installation to gas control valve (see included). Place battery into battery hous- Figu

Summary of the content on the page No. 14

INstallatIoN Continued Complete your gas installation by connect- ing incoming gas line with flexible gas line. C A U T I O N : C o m p o u n d s u s e d Secure tightly with wrench but DO NOT on threaded joints of gas piping OVERTIGHTEN. shall be resistant to the action of Liquefied Petroleum (LP or EMBER AND PAN MATERIAL propane) and should be applied PLACEMENT lightly to ensure excess sealant 1. Open bag(s) of vermiculite and fill entire burner pan until

Summary of the content on the page No. 15

INstallatIoN Continued Grate Pan and Ember NOTICE: Do not put lava rock in- 0.5" Material s i d e b u r n e r p a n o r a r o u n d t h e a i r mixer fitting. Placing lava rock inside burner pan or blocking openings of the propane/LP air- 0.5" mixer could cause performance problems. Burner Pan Figure 24 - Pan and Ember Material Log 4 Clearances LOG PLACEMENT FOR M36, M36P , Log 3 VM36 AND VM36P MODELS Log 2 1. Place small front right log (log 1) on right No

Summary of the content on the page No. 16

INstallatIoN Continued 5. Place upper end of log 5 into notch on top LOG PLACEMENT FOR M42, M42P , inner right of log 1 (see Figure 31). Rest VM42 AND VM42P MODELS lower end of log 5 on middle grate finger 1. Place large back log (log 1) onto grate as shown in Figure 32. making sure notches rest over grate (see 6. Place log 6 into notch on top right of log Figure 29). 1 (see Figure 31). Rest lower end of log 2. Insert lower end of log 2A between first 6 on top of log 2B (see Figure 32).

Summary of the content on the page No. 17

INstallatIoN Continued COMBUSTION AIR KIT MODEL AK4 INSTALLING OPTIONAL GLASS (OPTIONAL) DOOR ACCESSORY The outside air kit may be installed on the left CAUTION: Use only glass side of fireplace only. The vent can be installed through any outside wall a minimum of three doors certified for use with this feet below fireplace termination cap. The appliance. handle to operate damper door for outside air inlet will be located inside the left “screen Note: Glass door may be heavy for som

Summary of the content on the page No. 18

INstallatIoN Continued 6. Repeat the process for the opposite door Spring Hold-Down Clip assembly. Screw 7. To adjust doors, slide them partially open. Side Using a screwdriver, loosen hold-down Front screws in the spring clip (see Figure 36) Face and pivot plate. 8. Close both doors until evenly joined at the Partially middle and note the gap at outer edges of Opened face. Door 9. Reopen one door at a time and retighten Figure 36 - Adjusting Glass Doors upper and lower hold-down scr

Summary of the content on the page No. 19

oPeratIoN FOR YOUR SAFETY 1. STOP! Read the safety information, col- umn 1. READ BEFORE LIGHTING 2. Turn wall switch to the OFF position. WARNING: If you do not fol- 3. Turn off all electric power to appliance. low these instructions exactly , 4. Fully open glass doors if installed. 5. Remove front refractory brick access a fire or explosion may result panel. causing property damage, per- 6. Turn gas control knob clockwise sonal injury or loss of life. to the OFF position (see F

Summary of the content on the page No. 20

oPeratIoN Continued Note: Burner may light if hand-held remote TO TURN OFF GAS was on when selector switch was last TO APPLIANCE turned off. You can now turn burner on 1. Turn off wall switch. and off with the hand-held remote control 2. Turn off all electric power to appliance if unit. service is to be performed. IMPORTANT: Do not leave selector switch 3. Fully open glass doors if installed. in the REMOTE or ON position when pilot 4. Remove front hearth brick and control is not lit.


Alternative user manuals
# User manual Category Download
1 Desa (V)368ST User manual Indoor Fireplace 0
2 Desa (V)B36L User manual Indoor Fireplace 0
3 Desa (V)C36 User manual Indoor Fireplace 0
4 Desa (V)C36H User manual Indoor Fireplace 1
5 Desa (V)B36LI User manual Indoor Fireplace 0
6 Desa (V)C36I User manual Indoor Fireplace 1
7 Desa (V)B36I User manual Indoor Fireplace 1
8 Desa (V)C36L User manual Indoor Fireplace 0
9 Desa (V)B36 User manual Indoor Fireplace 4
10 Desa (V)C36LH User manual Indoor Fireplace 0
11 Desa (V)C36LI User manual Indoor Fireplace 0
12 Desa (V)CB36N(E) User manual Indoor Fireplace 0
13 Desa (V)CB36P(E) User manual Indoor Fireplace 0
14 Desa (V)DVF36 User manual Indoor Fireplace 2
15 Desa (V)G36 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1