Desa H) AND VM42E(B user manual

User manual for the device Desa H) AND VM42E(B

Device: Desa H) AND VM42E(B
Category: Indoor Fireplace
Manufacturer: Desa
Size: 4.58 MB
Added : 6/5/2013
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa H) AND VM42E(B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa H) AND VM42E(B.

For your convenience

If looking through the Desa H) AND VM42E(B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa H) AND VM42E(B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa H) AND VM42E(B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa H) AND VM42E(B User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa H) AND VM42E(B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa H) AND VM42E(B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

B-VENT DECORATIVE GAS FIREPLACE
OWNER’S OPERATION AND
TM
INSTALLATION MANUAL
For more information, visit www.desatech.com For more information, visit www.desatech.com
MODELS M36E(B,H), M42E(B,H), VM36E(B,H) AND VM42E(B,H)
ELECTRONIC IGNITION - NATURAL GAS
SAVE THIS MANUAL
WARNING: If the information in these instruc-
This manual is valuable. In addition to instruct-
tions is not followed exactly, a fire or explosion
ing you on how to install and maintain your
may result causing property damage,

Summary of the content on the page No. 2

TABLE OF CONTENTS 2 SAFETY INFORMATION TABLE OF CONTENTS CLEANING AND MAINTENANCE ............................................ 18 SAFETY INFORMATION ............................................................ 2 SERVICE HINTS....................................................................... 19 UNPACKING ............................................................................... 3 TECHNICAL SERVICE ............................................................. 19 INTRODUCTION.............

Summary of the content on the page No. 3

SAFETY INFORMATION 3 UNPACKING 3 SAFETY INFORMATION UNPACKING Continued The following items are packed inside the firebox. Remove before positioning firebox into framing. 7. A hearth extension is not required with this appliance. If one is installed, it is for aesthetic purposes only and does not have to • Transition Collar - For vent connection meet the standard requirements. • Ceramic Log Pack - Shrink-wrapped on cardboard 8. Turn fireplace off and let cool before servicing or repairing. • Thr

Summary of the content on the page No. 4

INTRODUCTION 4 Before You Begin INTRODUCTION Models M36E(B,H), VM36E(B,H), M42E(B,H) and VM42E(B,H) The installation must conform with local codes or, in the absence of are vented gas fireplaces that use an electronic gas control valve and local codes, with the current National Fuel Gas Code, ANSI Z223.1 electronic ignition system. A 6" B-Type venting system and a listed or with the current CAN/CGA B149 Installation Codes. type vent cap are not supplied but are required for proper operation. Thi

Summary of the content on the page No. 5

PRODUCT SPECIFICATIONS 5 5 PRODUCT SPECIFICATIONS A F For Use With 6"Ø Type B-1 Vent Pipe Only E HEARTH AREA H DIMENSIONS Stand Off D Collar 7" B C G Alternate 7" Gas Supply Inlet 1.5" X Glass Door 13.5" (Optional) K Outside Air I Kit Location O J N (Optional) S S R W T 7" T P L V Q M P Model 36 Model 42 Model 36 Model 42 A 29" 36" M 42" 49" B 5/8" 5/8" N 36" 40" C 41" 48" O 37" 41" 5 1 D 12" 14" P 8 /8" 10 /2" 1 7 E 21 /4" 23" Q 13 /8" 14" 1 1 1 1 F 22 /4" (24" w/o Brick) 29 /4" (31" w/o Bri

Summary of the content on the page No. 6

SELECTING LOCATION 6 PRE-INSTALLATION PREPARATION Clearances SELECTING LOCATION PRE-INSTALLATION To determine the safest and most efficient location for your appli- PREPARATION ance, you must take into consideration the following guidelines: CLEARANCES 1. The location must allow for proper clearances (see Clearances, next column). Minimum clearances to combustibles are: • Back and Sides of Outer Surround ............................ 0" min. 2. Consider a location where heat output would not be a

Summary of the content on the page No. 7

PRE-INSTALLATION PREPARATION 7 Mantel Clearances and Wall Details 7 PRE-INSTALLATION PREPARATION Continued MANTEL CLEARANCES AND WALL DETAILS TOP VIEW A combustible mantle shelf maybe installed a maximum 12" (229 mm) Outer Surround from the wall. Figures 5 and 6 show the minimum allowable distances Combustible from various combustible mantle components in relation to the fire- Material May place opening. Be Used SAFE 1 ZONE Combustible 1 /2" (38mm) 12" Max. 3" (76mm) (229mm) Materials Max. Heade

Summary of the content on the page No. 8

PRE-INSTALLATION PREPARATION 8 Framing Installing Transition Vent Collar PRE-INSTALLATION PREPARATION Continued These Dimensions Allow for a 3/4" FRAMING Clearance at Sides and Back of 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Fireplace. However, 0" Clearance is Permitted Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. D 2. Place the appliance into the framing and secure it. C 3/4" Clearance Note: If ap

Summary of the content on the page No. 9

VENTING INSTALLATION 9 9 VENTING INSTALLATION A B-type venting system must be connected to the appliance for Example 1: Shows the minimum allowable system height and venting to the outside of the building. lateral offset for a 60° degree or greater inclination. Code specifies that offsets at 60° degrees or greater are considered horizontal and The following section is provided as a guide to a standard B-type must follow the 75% percent rule for lateral to total vertical system vent installation.

Summary of the content on the page No. 10

VENTING INSTALLATION 10 Checking for Proper Venting VENTING INSTALLATION Continued Vent terminations must be located in accordance with height and Note: Before connecting this appliance to an existing vent system proximity rules of NFPA No. 54 or CAN/CGA B149. These rules or a common venting system consult with your local architect, apply to vents at 12 in. diameter or less and require a minimum planner, or building official. height in accordance with the roof pitch and a minimum of 8 ft. distan

Summary of the content on the page No. 11

INSTALLATION 11 Wall Switch Installation 11 Optional Remote Control Installation Gas Line Hook-Up INSTALLATION Battery Cover WALL SWITCH INSTALLATION 12 Volt Battery The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. Refer to wiring diagram in Back of Pull to Remove this manual on page 19. Handset Insul

Summary of the content on the page No. 12

INSTALLATION 12 Gas Line Hook-Up (Cont.) Ember and Pan Material Placement INSTALLATION Continued DESA recommends that a black iron gas line be routed from the gas EMBER AND PAN MATERIAL PLACEMENT source, through a sediment trap (shown in Figure 18), and into the 1. Open the bag(s) of vermiculite and fill the entire burner pan appliance, Once connected through the appliance, a flexible gas line until the burner tube is completely covered (see Figure 20). may be used for ease of installation to

Summary of the content on the page No. 13

INSTALLATION 13 Log Placement for M36E/VM36E Models 13 INSTALLATION Continued Log 4 LOG PLACEMENT FOR M36E/VM36E MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 23. Log 3 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 23. 3. Place log 3 across logs 1 and 2 aligning pegs on log 3 with holes in logs 1 and 2 (see Figure 24). 4. Place the top of log 4 across the right side of log 2, aligning peg in log 4 with

Summary of the content on the page No. 14

INSTALLATION 14 Log Placement for M42E/VM42E Models INSTALLATION Continued LOG PLACEMENT FOR M42E/VM42E MODELS 1. Place log 1A on the front left side of grate. Place log 1B on the Log 3 front right side of the grate. See Figure 27. Log 4 2. Place large back log (log 2) onto grate making sure notches Log 1A rest over grate. Insert peg on back of log 1A into hole on front left of log 2 (see Figure 27). 3. Place log 3 across log 1A and log 2, aligning peg on log 3 with Log 2 top left hole on log 2

Summary of the content on the page No. 15

INSTALLATION 15 Combustion Air Kit Model AK4 (Optional) 15 Appliance Enclosure Installing Optional Glass Door Accessory INSTALLATION Continued COMBUSTION AIR KIT MODEL AK4 INSTALLING OPTIONAL GLASS DOOR (OPTIONAL) ACCESSORY The outside air kit may be installed on the left side of the fireplace CAUTION: Use only glass doors certified for use only. The vent can be installed through the outside wall or a with this appliance. ventilated crawl space. The handle to operate the damper door for the ou

Summary of the content on the page No. 16

INSTALLATION 16 Installing Optional Glass Door Accessory (Cont.) Opening Vent Damper INSTALLATION Continued 5. Once the top and bottom pins are secured, unfold the door into Spring Clip the closed position. 6. Repeat the process for the opposite door assembly. Depress Spring 7. To adjust the doors, slide them partially open. Using a screw- Clip to Release Pivot Pin driver, loosen the hold-down screws in the spring clip (see Fig- Fold Bi-Fold ure 34) and pivot plate. Door After 8. Close both door

Summary of the content on the page No. 17

OPERATING FIREPLACE 17 For Your Safety Read Before Lighting 17 Lighting Instructions To Turn off Gas to Appliance Optional Remote Operation OPERATING FIREPLACE 13. Visually locate the pilot. The ignitor should begin to spark FOR YOUR SAFETY and the main burner should ignite once flame appears at READ BEFORE LIGHTING pilot. • If lighting the appliance for the first time each season, it WARNING: If you do not follow these instructions may take several attempts before the supply gas can reach exac

Summary of the content on the page No. 18

INSPECTING BURNERS 18 Pilot Assembly Burner Flame Pattern CLEANING AND MAINTENANCE Pilot and Burner Logs INSPECTING BURNERS CLEANING AND Check pilot flame pattern and burner flame patterns often. MAINTENANCE PILOT ASSEMBLY WARNING: Installation and repair should be done The pilot assembly is factory preset for the proper flame. Alterations by a qualified service person. The appliance should may have occurred during shipping and handling. The pilot is be inspected before each use and at least an

Summary of the content on the page No. 19

Robertshaw MODEL SP745 IGNITION CONTROL IGN PV GND TR PV/MV TH MV SERVICE HINTS 19 19 TECHNICAL SERVICE WIRING DIAGRAM REPLACEMENT PARTS SERVICE HINTS REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your When Gas Pressure Is Too Low warranty coverage for parts replaced under warranty. • pilot will not stay lit PARTS UNDER WARRANTY • burner will have delayed ignition • fireplace will not produce specified heat Contact authorized dealers of this product. If they can’

Summary of the content on the page No. 20

TROUBLESHOOTING 20 The two most common causes of a malfunctioning gas appliance are: TROUBLESHOOTING 1. Loose wiring connections Note: For additional help, visit DESA International’s technical 2. Construction debris clogging the pilot and/or gas control valve filter service web site at www.desatech.com. Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Ignitor will not spark or pilot will not light 1. No gas supply, or shutoff


Alternative user manuals
# User manual Category Download
1 Desa (V)368ST User manual Indoor Fireplace 0
2 Desa (V)B36L User manual Indoor Fireplace 0
3 Desa (V)C36 User manual Indoor Fireplace 0
4 Desa (V)C36H User manual Indoor Fireplace 1
5 Desa (V)B36LI User manual Indoor Fireplace 0
6 Desa (V)C36I User manual Indoor Fireplace 1
7 Desa (V)B36I User manual Indoor Fireplace 1
8 Desa (V)C36L User manual Indoor Fireplace 0
9 Desa (V)B36 User manual Indoor Fireplace 4
10 Desa (V)C36LH User manual Indoor Fireplace 0
11 Desa (V)C36LI User manual Indoor Fireplace 0
12 Desa (V)CB36N(E) User manual Indoor Fireplace 0
13 Desa (V)CB36P(E) User manual Indoor Fireplace 0
14 Desa (V)DVF36 User manual Indoor Fireplace 2
15 Desa (V)G36 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1