Panasonic CU-C12DKU user manual

User manual for the device Panasonic CU-C12DKU

Device: Panasonic CU-C12DKU
Category: Air Conditioner
Manufacturer: Panasonic
Size: 6.68 MB
Added : 7/9/2013
Number of pages: 77
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Panasonic CU-C12DKU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Panasonic CU-C12DKU.

For your convenience

If looking through the Panasonic CU-C12DKU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Panasonic CU-C12DKU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Panasonic CU-C12DKU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Panasonic CU-C12DKU User manual - Online PDF
Advertisement
« Page 1 of 77 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Panasonic CU-C12DKU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Panasonic CU-C12DKU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Order No. MAC0502033C1
Air Conditioner
CS-C9DKU CU-C9DKU
CS-C12DKU CU-C12DKU
CONTENTS
Page Page
1 Features 2 8.5. IndoorFanSpeedControl 21
2 Functions 3 8.6. OutdoorFanSpeedControl 23
3 ProductSpecifications 6 8.7. VerticalAirflowDirectionControl 23
3.1. CS-C9DKU CU-C9DKU 6 8.8. HorizontalAirflowDirectionControl 24
3.2. CS-C12DKU CU-C12DKU 8 8.9. PowerfulOperation 24
4 Dimensions 10 8.10. Quiet Operation 25
4.1. IndoorUnit&RemoteControl 10 8.11. Timer Control 26
4.2. OutdoorUnit 11 8.12

Summary of the content on the page No. 2

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 10.5. Indoor unit 37 13 Troubleshooting Guide 57 10.6. Outdoor unit 40 13.1. Refrigeration cycle system 57 11 2-way, 3-way Valve 45 13.2. Relationship between the condition of the air conditioner 11.1. Evacuation of Installation 46 and pressure and electric current 58 11.2. Pumping down 47 13.3. Diagnosis methods of a malfunction of a compressor 58 11.3. Evacuation of Re-installation 48 14 Technical Data 59 11.4. Balance refrigerant of the 2-way, 3-

Summary of the content on the page No. 3

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 2 Functions ı 3

Summary of the content on the page No. 4

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 4

Summary of the content on the page No. 5

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 5

Summary of the content on the page No. 6

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 3 ProductSpecifications 3.1. CS-C9DKUCU-C9DKU Unit Indoor unit Outdoor unit Power Source (Phase, Voltage, Cycle) ø, V, Hz Single, 115, 60 Cooling Capacity kW (BTU/h) 2.58 (8,800) Moisture Removal l/h (Pint/h) 1.0 (2.1) Airflow Method OUTLET SIDE VIEW TOP VIEW INTAKE 3 Air Volume Lo m /min (cfm) 4.7 (164) - 4.7 (164) — 3 Me m /min (cfm) 5.7 (202) - 5.7 (202) — 3 Hi m /min (cfm) 7.2 (250) - 7.2 (250) 33.8 (1,190) 3 SHi m /min (cfm) 7.8 (274) - 7.8 (274) — No

Summary of the content on the page No. 7

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU Unit Indoor unit Outdoor unit Thermostat Electrical — Protection Device — 2 Stage Overload Protector Capillary Tube Length inch (mm) — 26-18/32 (675) Flow Rate l/min — 13.0 Inner Diameter inch (mm) — 20/32 (1.6) Air Filter Material P.P. — Style Honeycomb Capacity Control Capillary Tube Compressor Capacitor µF, VAC — 35 µF, 370VAC Fan Motor Capacitor µF, VAC 5.0 µF, 230VAC 8.0 µF, 230VAC Note: • Specifications are subjected to change without prior notice f

Summary of the content on the page No. 8

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 3.2. CS-C12DKUCU-C12DKU Unit Indoor unit Outdoor unit Power Source (Phase, Voltage, Cycle) ø, V, Hz Single, 115, 60 Cooling Capacity kW (BTU/h) 3.60 (12,300) Moisture Removal l/h (Pint/h) 1.6 (3.4) Airflow Method OUTLET SIDE VIEW TOP VIEW INTAKE 3 Air Volume Lo m /min (cfm) 5.6 (199) - 5.6 (199) — 3 Me m /min (cfm) 6.8 (238) - 6.8 (238) — 3 Hi m /min (cfm) 8.0 (280) - 8.0 (280) 31.1(1,100) 3 SHi m /min (cfm) 8.2 (289) - 8.2 (289) — Noise Level dB (A) High

Summary of the content on the page No. 9

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU Unit Indoor unit Outdoor unit Capillary Tube Length inch (mm) — 16-23/32 (425) Flow Rate l/min — 18.0 Inner Diameter inch (mm) — 2/32 (1.7) Air Filter Material P.P. — Style Honeycomb Capacity Control Capillary Tube Compressor Capacitor µF, VAC — 50 µF, 370VAC Fan Motor Capacitor µF, VAC 5.0 µF, 230VAC 8.0 µF, 230VAC Note: • Specifications are subjected to change without prior notice for further improvement. 9

Summary of the content on the page No. 10

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 4 Dimensions 4.1. IndoorUnit&RemoteControl 10

Summary of the content on the page No. 11

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 4.2. OutdoorUnit CU-C9DKU CU-C12DKU 11

Summary of the content on the page No. 12

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 5 RefrigerationCycleDiagram CS-C9DKU CU-C9DKU CS-C12DKU CU-C12DKU 12

Summary of the content on the page No. 13

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 6 BlockDiagram CS-C9DKU CU-C9DKU CS-C12DKU CU-C12DKU 13

Summary of the content on the page No. 14

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 7 WiringDiagram CS-C9DKU CU-C9DKU REMARKS CS-C12DKU CU-C12DKU B : BLUE BR : BROWN BL : BLACK GRY : GRAY O : ORANGE P : PINK R : RED W : WHITE Y/G : YELLOW/GREEN Power Supply Cord Resistance of Indoor Fan Motor Windings MODEL CS-C9DKU CS-C12DKU CONNECTION CWA921143 BLUE-YELLOW 82.4 Ω YELLOW-RED 103.4 Ω Note: Resistance at 68°F of ambient temperature. Resistance of Outdoor Fan Motor Windings MODEL CU-C9DKU CU-C12DKU CONNECTION CWA951244 BLUE-YELLOW 61.2 Ω YE

Summary of the content on the page No. 15

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 8 OperationDetails 8.1. CoolingOperation • Cooling operation can be set using remote control. • This operation is applied to cool down the room temperature reaches the setting temperature set on the remote control. • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 60.8°F to 86°F. • During cooling operation, the compressor will stop running and restart as shown in below figure. 8.1.1

Summary of the content on the page No. 16

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 8.2. SoftDryOperation • Soft Dry operation can be set using remote control. • Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room. • This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control. • When operation begins, Soft Dry will be switched “ON” for a maximum 10 minutes, then Soft Dry operation will be turned “OFF” for a minimum 6 minutes. After that, the Sof

Summary of the content on the page No. 17

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 8.3. AutomaticOperation • Automatic operation can be set using remote control. • This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature. • After judged the temperature, the operation mode is determined by referring to the below standard. • Then, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting temperature as shown in below ta

Summary of the content on the page No. 18

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 8.4. OperationControl 8.4.1. RestartControl(TimeDelaySafetyControl) • When the thermo-off temperature (temperature which compressor stops to operate) is reached during:- − Cooling/Heating operation - the compressor stops for 3 minutes (minimum) before resume operation. − Soft Dry operation - the compressor stops for 6 minutes (minimum) before resume operation. • If the operation is stopped by the remote control, the compressor will not turn on within 3

Summary of the content on the page No. 19

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 8.4.5. Anti-FreezingControl • If the temperature of the indoor heat exchanger falls below 35.6°F continuously for 4 minutes or more, the compressor turns off. The fan speed setting remains the same. • This phenomenon is to protect the indoor heat exchanger from freezing and to prevent higher volume of refrigerant in liquid form returning to the compressor. • Compressor will restart again when the indoor heat exchanger temperature rises to 50°F (Recovery

Summary of the content on the page No. 20

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU • Anti-Dew Formation is control by:- • Increasing Air Flow Volume 1. Lo fan speed. Lo fan speed is changed to Lo+ after 30 min to prevent dew formation. 2. QLo fan speed. Dew formation may occur at QLo cool, therefore QLo cool is operated only 1hr 30min (1 hr QLo, 30 min QLo + 80 rpm). After that, it operates at QLo + 160 rpm (However Quiet LED remains on). • Narrowing 1. Vertical Airflow Direction During Anti-Dew condensation prevention, Airflow Dir


Alternative user manuals
# User manual Category Download
1 Panasonic CS-1873KR User manual Air Conditioner 243
2 Panasonic CS-A12CKPG User manual Air Conditioner 72
3 Panasonic CS-A12CKP User manual Air Conditioner 98
4 Panasonic AC Robot 2006/2007 User manual Air Conditioner 45
5 Panasonic 2008 User manual Air Conditioner 83
6 Panasonic CS-A18CTP User manual Air Conditioner 28
7 Panasonic AW-PS505 User manual Air Conditioner 6
8 Panasonic CS-A12CTP User manual Air Conditioner 31
9 Panasonic CS-A24CTP User manual Air Conditioner 36
10 Panasonic CS-A24CKPG User manual Air Conditioner 4
11 Panasonic CS-A7CKP User manual Air Conditioner 207
12 Panasonic CS-A9CKP User manual Air Conditioner 45
13 Panasonic CS-A9CKPG User manual Air Conditioner 9
14 Panasonic CS-C12CKP User manual Air Conditioner 19
15 Panasonic CS-C24BKP User manual Air Conditioner 33
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21