Desa CD32M(-1)(-2) user manual

User manual for the device Desa CD32M(-1)(-2)

Device: Desa CD32M(-1)(-2)
Category: Indoor Fireplace
Manufacturer: Desa
Size: 3.36 MB
Added : 4/12/2014
Number of pages: 19
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa CD32M(-1)(-2). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa CD32M(-1)(-2).

For your convenience

If looking through the Desa CD32M(-1)(-2) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa CD32M(-1)(-2) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa CD32M(-1)(-2) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa CD32M(-1)(-2) User manual - Online PDF
Advertisement
« Page 1 of 19 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa CD32M(-1)(-2) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa CD32M(-1)(-2). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

C
E
N
R
G
T
I


CD32M(-1)(-2)


CD36M(-1)(-2)


CD42M

DIRECT VENT GAS FIREPLACE

INSTALLATION INSTRUCTIONS


SAVE THIS BOOK

This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will

enable yo

Summary of the content on the page No. 2

CONTENTS 1. INTRODUCTION ------------------------------------------------------------ PG. 2 2. SELECTING LOCATION ------------------------------------------------------------- PG. 2 3. MINIMUM CLEARANCES ------------------------------------------------------------- PG. 3 4. VENT PIPE AND TERM. CLEARANCES ------------------------------------------------------------- PG. 3-4 5. VENTING INSTRUCTIONS ------------------------------------

Summary of the content on the page No. 3

a) Modification of the fireplace, components, doors, blower, FOR YOUR SAFETY fans, air inlet system and damper control. • Do not store or use gasoline or any other flammable b) Use of any component part not manufactured or approved vapors or liquids in the vicinity of this or any other by DESA/Coleman in combination with a DESA/Coleman appliance. fireplace system. • Due to high temperatures, the appliance should be located out of traffic and away from furniture and PROPER INSTAL

Summary of the content on the page No. 4

In selecting a location, the following precautions must be WARNING: Do not block required air space with observed: insulation or any other material. Do not obstruct effective opening of appliance with any type of facing Do not connect this appliance to a chimney system material. used for solid fuel burning fireplace. Due to high temperatures, do not locate this appliance in high traffic areas or near furniture and draperies. VENT TERMINATION CLEARANCES Never obstruct the front

Summary of the content on the page No. 5

VENT PIPE AND TERMINATION CLEARANCES The final position of your appliance depends on the location of the termination in relation to the clearances that must be observed. A= 12” (305mm) clearance above grade, veranda, porch, deck G= 6” (15mm) clearance to inside corner. or balcony. *** H= not to be installed above a meter/regulator within 3 feet B= 9” (229mm) clearance in U.S. and 12” (305mm) clearance (914mm) horizontally from th

Summary of the content on the page No. 6

VENT INSTALLATION INSTRUCTIONS 7. An optional siding standoff may be installed between the vent cap exterior wall. Secure horizontal top to 1. Install pipe to fireplace collar adapter located on back standoff and then secure the complete assembly to of unit at a 45 deg. Angle. Connect our starting pipe wall (see figure 6). The vent termination must be to a 45 deg. Starting section by sliding it over the removable for service pipe inspection. collar adapter on the fireplace. Twist-lock

Summary of the content on the page No. 7

Refer to the following table for clearance between roof and termination. ROOF PITCH MINIMUM HEIGHT ABOVE ROOF ft mm FLAT - 7/12 1 305 7/12 - 8/12 1.5 457 8/12 - 9/12 2 610 9/12 - 10/12 2.5 762 10/12 - 11/12 4 1219 12/12 - 14/12 5 1524 14/12 - 16/12 6 1829 16/12 - 18/12 7 2134 18/12 - 20/12 7.5 2286 Figure 9 CORNER INSTALLATION 20/12 - 21/12 8 2438 FRAMING CD32M CD36M CD42M Once the final location has been determined (observing A 28-1/

Summary of the content on the page No. 8

The remote control receiver is factory wired and connected to In conformance with local codes, route a ½” NPT gas line the convertible gas valve as shown in figure 11. towards the appliance coming in from either the left or right side of the fireplace (see figure 14). CAUTION: Do not kink flexible gas line. Figure 12 GAS CONTROL VALVE Figure 11 REMOTE CONTROL RECEIVER GAS SUPPLY TESTING NOTE: This secti

Summary of the content on the page No. 9

Install a sediment trap between the incoming gas line and the CAUTION: All gas piping and connections must be tested gas control box (see figure 15). The sediment trap should for leaks after the installation is completed. After ensuring extend down a minimum of 3 inches (76 mm) beyond the that the gas valve is on, apply a commercial leak detection center of the pipe. solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN O

Summary of the content on the page No. 10

GLASS PANEL REMOVAL FOR MODELS CD32M AND CD36M SERIES Before proceeding, make sure gas control valve is in the • Place log #1 (back log) on top of grate. Make sure “OFF” position. the notches in the bottom of the log fit over the grate. 1. To remove louvers, pull both spring latches (located • Rest log #2 (large front log) on the pins on the front in each end of louver) towards center of appliance part of the grate. simultaneously until disengaged from locating holes. • Place log #3

Summary of the content on the page No. 11

• Place log #6 (left log) onto left pin of front log (#2) WARNING: Improper installation, adjustment, and the smooth surface of rear log (#3). Make sure it alteration, service or maintenance can cause injury or is seated properly. property damage. Refer to this manual for assistance. • Place log #7 onto right pin of top log (#5). Make sure Consult a qualified installer for additional information. it is seated properly. NOTICE: D

Summary of the content on the page No. 12

- 11 - For more information, visit www.desatech.com

Summary of the content on the page No. 13

CONVERSION KIT • Replace pilot orifice with LP orifice supplied with this kit. The number 30 is stamped on the sleeve for This conversion kit is packaged with the unit. Please check identification. Insert the small end of the new pilot the contents before beginning this conversion. orifice into the barrel and thread until tight with the allen wrench. • Before proceeding, make sure the gas control valve is in the “OFF” position and all electrical power to the • Line up the notch

Summary of the content on the page No. 14

• Install the identification label enclosed with the FACE EXTENSION (FOR MODEL CD32M ONLY) gas valve regulator to the valve body where it can easily be seen (see figure 23). Model CD32M comes equipped with a front face extension. The front face extension would add 3- ½” to the width and ¾” to the height of the fireplace face. To install the face extension: • Remove the existing screws from front face assembly as shown in figure 24. • Align holes on top face extensio

Summary of the content on the page No. 15

OBSERVED PROBLEM POSSIBLE CAUSE REMEDY • Pilot will not stay lit after • Defective pilot generator • Check pilot flame. It must carefully following lighting (thermocouple). impinge on thermocouple. instructions. • Clean or adjust pilot for maximum flame impingement on thermocouple. • Ensure that the connection between the valve and thermocouple are tight and secured. • Pilot lit but no flame on the • Remote or wires de

Summary of the content on the page No. 16

ILLUSTRATED PARTS BREAKDOWN MODELS CD32M AND CD36M SERIES - 15 - For more information, visit www.desatech.com

Summary of the content on the page No. 17

ILLUSTRATED PARTS BREAKDOWN MODEL CD42M - 16 - For more information, visit www.desatech.com

Summary of the content on the page No. 18

ILLUSTRATED PARTS LIST ITEM PART # DESCRIPTION QTY. CD32M CD36M CD42M 1 108878-01 108008-01 108326-01 FIREBOX ASSEMBLY 1 2 108874-01 108009-01 108327-01 FACE WELDMENT 1 3 108892-01 108010-01 108328-01 DOOR ASSEMBLY 1 4 108903-01 108011-01 108331-01 PANEL ASSEMBLY LOUVER, FACE TOP 1 5 108903-02 108011-02 108331-03 PANEL ASSEMBLY LOUVER, FACE BOTTOM 1 6 108895-01 108015-01 108333-01 TOP, FIREPLACE 1 7 109096-01 108016-01 108336-01 INSULATION, FIREPLACE TOP 1 8 108896-01 108017-01 108334-01

Summary of the content on the page No. 19

ACCESSORY AND REPLACEMENT PARTS - 18 - For more information, visit www.desatech.com


Alternative user manuals
# User manual Category Download
1 Desa (V)368ST User manual Indoor Fireplace 0
2 Desa (V)B36L User manual Indoor Fireplace 0
3 Desa (V)C36 User manual Indoor Fireplace 0
4 Desa (V)C36H User manual Indoor Fireplace 1
5 Desa (V)B36LI User manual Indoor Fireplace 0
6 Desa (V)C36I User manual Indoor Fireplace 1
7 Desa (V)B36I User manual Indoor Fireplace 1
8 Desa (V)C36L User manual Indoor Fireplace 0
9 Desa (V)B36 User manual Indoor Fireplace 4
10 Desa (V)C36LH User manual Indoor Fireplace 0
11 Desa (V)C36LI User manual Indoor Fireplace 0
12 Desa (V)CB36N(E) User manual Indoor Fireplace 0
13 Desa (V)CB36P(E) User manual Indoor Fireplace 0
14 Desa (V)DVF36 User manual Indoor Fireplace 2
15 Desa (V)G36 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1