Desa (V)T32P user manual

User manual for the device Desa (V)T32P

Device: Desa (V)T32P
Category: Indoor Fireplace
Manufacturer: Desa
Size: 2.22 MB
Added : 8/30/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa (V)T32P. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa (V)T32P.

For your convenience

If looking through the Desa (V)T32P user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa (V)T32P on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa (V)T32P to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa (V)T32P User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa (V)T32P but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa (V)T32P. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
NATURAL GAS “TUDOR” MODEL
(V)T32N, (V)T36N SERIES, CHDV32NR, CTDV36NR
PROPANE/LP GAS “TUDOR” MODEL (V)T32P, (V)T36P SERIES
WARNING: If the information in this manual is
WARNING: Improper installation, adjust-
not followed exactly, a fire or explosion may
ment, alteration, service, or maintenance
result causing property damage, personal
can cause injury or property damage. Refer
injury, or loss of life.
to this manual for correc

Summary of the content on the page No. 2

TAbLE OF CONTENTS Safety Information ........................................................................ Cleaning and Maintenance ......................................................... 6 Product Identification ....................................................................3 Troubleshooting .......................................................................... 7 Local Codes..................................................................................3 Replacement Parts ...

Summary of the content on the page No. 3

SAFETy INFORMATION LOCAL CODES Install and use fireplace with care. Follow all local codes. In the Continued absence to local codes, use the current National Fuel Gas Code 12. Do not use this fireplace to cook food or burn paper or other ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- objects. lation Code (Canada). 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) *Available from: in this fireplace. Use only the gas type indicated on fireplace American Nation

Summary of the content on the page No. 4

PRE-INSTALLATION PREPARATION LOCAtION AND SPACE REqUIREMENtS Flush with a wall Determine the safest and most efficient location for your DESA Corner direct-vent fireplace. Make sure that rafters and wall studs are not installation in the way of the venting system. Choose a location where the heat Through exterior wall output is not affected by drafts, air conditioning ducts, windows enclosed in a chase or doors. Figure 2 shows some common locations. Be aware of all restrictions and preca

Summary of the content on the page No. 5

PRE-INSTALLATION 1 2 PREPARATION Continued 3 A Wall FRAMING AND FINISHING 4 Figure 4 shows typical framing of this fireplace. Figure 5 shows fram- B 5 ing for corner installation. All minimum clearances must be met. C 6 For available accessories for this fireplace, see Accessories on page D 31. If you are using a separate combustible mantel piece, refer to E 7 Figure 6 for proper installation height. You can install noncombustible F G mantels at any height above the fireplace. Note: Noncombu

Summary of the content on the page No. 6

V G G V A E D V B L LOCATION OF TERMINATION CAP N N H C I B Fixed V V Fixed Closed Openable Closed Openable B F V J G V X B B M A V K X TERMINATION CAP G GAS METER RESTRICTED AREA V X AIR SUPPLY INLET (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72" (182.9 cm) [*12" (30.5 cm) minimum] minimum] B = clearance to window or door that may be opened J = clearance to non-mechanical air supply inlet to building

Summary of the content on the page No. 7

INSt ALLAtION PRECAUtIONS VENTING INSTALLATION • Wear gloves and safety glasses for protection INSTRUCTIONS • Use extreme caution when using ladders or when on roof tops • Be aware of electrical wiring locations in walls and ceilings NOtICE: Read these instructions completely before The following actions will void the warranty on your venting system: attempting installation. • Installation of any damaged venting component These models are tested and approved for use with DESA (direct- • Unauth

Summary of the content on the page No. 8

VENTING INSTALLATION Female Locking Lugs INSTRUCTIONS Continued 2. Direct vent pipe sections and components are designed with Male special twist-lock connections. Slots t wist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approxi- Figure 8 - Vent Pipe Connections mately one-quarter turn until the sections are

Summary of the content on the page No. 9

VENTING INSTALLATION INSTRUCTIONS Minimum Pipe Siding Standoff Continued 1 Overlap 1 / " 4 7. Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12). Screws 8. Carefully move fireplace, with vent assembly attached, toward Direct Vent wall and insert vent pipe into horizontal termination. The pipe Pipe 1 overlap should be a minimum of 1 /4". Wall Firestop 9. Slide wall firestop against interior wall surface and attach with screws provided. S

Summary of the content on the page No. 10

CORNER AND ALTERNATE INSTALLATION VENTING INSTALLATION Recommended Applications: INSTRUCTIONS • Corner ground floor installation Continued • Ground floor installation where pipe vents horizontally through wall (over 12" horizontal pipe) Horizontal t ermination Configurations Figures 14 through 18 show different configurations and alterna- • Basement installation where one foot clearance from ground to tives for venting with horizontal termination. Each figure includes termination is possible

Summary of the content on the page No. 11

VENTING INSTALLATION INSTRUCTIONS Continued SNORKEL TERMINATION INSTALLATION Recommended Applications: • Installations requiring a vertical rise on building exterior • Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termina- tion below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure

Summary of the content on the page No. 12

2. Assemble the desired lengths of pipe and elbows necessary to VENTING INSTALLATION reach from the fireplace flue up through the firestop. Be sure all INSTRUCTIONS pipe and elbow connections are fully twist-locked (see Figure 8, page 8). Continued 3. Cut a hole in the roof using the locating hole as a center point. INSt ALLAt ION FOR vERt ICAL t ERMINAt ION (Cover any exposed open vent pipes before cutting hole in Note: Vertical restrictor must be installed in all vertical installations.

Summary of the content on the page No. 13

VENTING INSTALLATION INSTRUCTIONS Continued Venting with Two 90° Elbows vertical t ermination Configurations Vertical (V ) Horizontal (H) 1 Figures 21 through 24 show four different configurations for verti- 5' min. 6' max. cal termination. 6' min. 1' max. 7' min. 18' max. Venting with Two 90° Elbows 8' min. 0' max. Vertical (V) Horizontal (H ) + 1 Horizontal (H )  5' min. ' max.  Note: Install restrictor 6' min. 4' max. into inner collar of fireplace as shown. 7' min. 6' max.

Summary of the content on the page No. 14

DESA Elbows VENTING INSTALLATION Number Description INSTRUCTIONS E47-45 45° Elbow - Galvanized Continued E47-90 90° Elbow - Galvanized HIGH ALTITUDE INSTALLATION DESA Terminations Your DESA direct-vent fireplace has been CSA tested and approved Number Description for elevations from 0-2000 feet (USA) and elevations from 0-4500 HT-47 Horizontal Round Termination - Galvanized feet (Canada). When installing this fireplace at an elevation above 2000 feet (in the HTS-47 Horizontal Square Terminat

Summary of the content on the page No. 15

Switch Speed Control FIREPLACE INSTALLATION Bracket Continued Blower Plug-In 3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25). Duplex Outlet (Located underneath firebox 4. Be certain that all wire terminals are securely attached to ter- Locknut floor against lower right minals on blower motor and that

Summary of the content on the page No. 16

blower Wiring Diagram FIREPLACE INSTALLATION Continued CAUtION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause im- 3. Place the blower against the lower rear wall of the firebox outer proper and dangerous operation. Verify proper opera- wrapper with the exhaust port directed upward and the thermo- tion after servicing. disc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28 Variabl

Summary of the content on the page No. 17

CSA Design-Certified FIREPLACE INSTALLATION Equipment Shutoff Valve Continued with 1/8" NPT Tap* Natural - From For propane/LP connection only, the installer must supply an Gas Meter (5.5" external regulator. The external regulator will reduce incoming W.C. to 10.5" gas pressure. You must reduce incoming gas pressure to between Approved Flexible W.C. Pressure) 11" and 14" of water. If you do not reduce incoming gas pressure, Gas Line Propane/LP fireplace regulator damage could occur.

Summary of the content on the page No. 18

PRESSURE tES t ING FIREPLACE GAS CONNECt IONS FIREPLACE INSTALLATION 1. Open equipment shutoff valve (see Figure 33). Continued 2. Open propane/LP supply tank valve for propane/LP fireplace CHECKING GAS CONNECtIONS or main gas valve located on or near gas meter for natural gas fireplace. WARNING: Test all gas piping and connections for 3. Make sure control knob of fireplace is in the OFF position. leaks after installing or servicing. Correct all leaks at once. 4. Check all joints from equi

Summary of the content on the page No. 19

Installing 9-volt Alkaline Battery in Hand-Held FIREPLACE INSTALLATION Remote Control Unit Continued 1. Remove battery cover on back of remote control unit. INSTALLING OPTIONAL WIRELESS HAND- 2. Attach terminal wires to a 9-volt alkaline battery (not included). HELD REMOtE CONtROL - HRC100 AND Place battery into the battery housing. HRC200 SERIES 3. Replace battery cover onto remote control unit. NOtICE: Use only alkaline batteries (not included). Remote Control Unit Battery Cover Installin

Summary of the content on the page No. 20

5. Close glass door frame. Lock latches by placing the bar under the FIREPLACE INSTALLATION tab on door and pushing down and back on latch (see Figure 41). Continued 6. Replace screen/rod assembly by reversing step 1. REMOvING/REPLACING GLASS DOOR 7. Replace louvers by reversing procedure under Removing Lou- ver Panels. CAUtION: Do not operate this fireplace with a bro - ken glass door panel or without the glass door panel Unlock Lock securely in place. For replacement part information see L


Alternative user manuals
# User manual Category Download
1 Desa (V)368ST User manual Indoor Fireplace 0
2 Desa (V)B36L User manual Indoor Fireplace 0
3 Desa (V)C36 User manual Indoor Fireplace 0
4 Desa (V)C36H User manual Indoor Fireplace 1
5 Desa (V)B36LI User manual Indoor Fireplace 0
6 Desa (V)C36I User manual Indoor Fireplace 1
7 Desa (V)B36I User manual Indoor Fireplace 1
8 Desa (V)C36L User manual Indoor Fireplace 0
9 Desa (V)B36 User manual Indoor Fireplace 4
10 Desa (V)C36LH User manual Indoor Fireplace 0
11 Desa (V)C36LI User manual Indoor Fireplace 0
12 Desa (V)CB36N(E) User manual Indoor Fireplace 0
13 Desa (V)CB36P(E) User manual Indoor Fireplace 0
14 Desa (V)DVF36 User manual Indoor Fireplace 2
15 Desa (V)G36 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1