Desa (V)G42/50 user manual

User manual for the device Desa (V)G42/50

Device: Desa (V)G42/50
Category: Indoor Fireplace
Manufacturer: Desa
Size: 1.56 MB
Added : 3/5/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa (V)G42/50. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa (V)G42/50.

For your convenience

If looking through the Desa (V)G42/50 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa (V)G42/50 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa (V)G42/50 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa (V)G42/50 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa (V)G42/50 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa (V)G42/50. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

42" and 50" Wood Burning Masonry Fireplace
oWner’s opera Tion and insT alla Tion Manual
(V)G42/50 - Smooth Face with Insulation
(V)G42R/50R - Smooth Face with Insulation and Bottom Door Rail
(V)G42H/50H - Smooth Face with Insulation and Herringbone Refractory
(V)G42HR/50HR - Smooth Face with Insulation, Bottom Door Rail
and Herringbone Refractory
SAVE THIS BOOK
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information th

Summary of the content on the page No. 2

TaBle oF conTenTs Safety Information ...............................................  Glass Door Installation ...................................... 1 Specifications ...................................................... 3 Operation and Maintenance Guidelines ............ 13 Fireplace Installation............................................ 5 Technical Service............................................... 14 Venting Installation .............................................. 7 Replacement Par

Summary of the content on the page No. 3

speciFica Tions 42" MODELS ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 1 1 /2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 18" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS HEARTH EXTENSION 66" X 20" 0" TO 12" EACH SIDE BOTTOM 12" 30.5" 11" 67" 21.25" 58" 28.5" 49" 30" 0.625" 51" 42" 8" 51" 1" AIR KIT KNOCK OUT LEFT SIDE 24.25" GAS LINE KNOCK OUTS 3.5" 10.5" 9.5"

Summary of the content on the page No. 4

speciFica Tions 50" MODELS ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 1 1 /2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 18" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS HEARTH EXTENSION 74" X 20" 0" TO 12" EACH SIDE BOTTOM 12" 38.5" 11" 67" 21.25" 58" 28.5" 49" 30" 0.625" 59" 50" 8" 59" 1" AIR KIT KNOCK OUT LEFT SIDE 32.75" GAS LINE KNOCK OUTS 3.5" 10.5"

Summary of the content on the page No. 5

and depth of the fireplace. Firea lp ce ins Taa ll Tion 3. Set the fireplace directly in front of this open- SELECTING LOCATION ing and slide the unit back until the nailing To determine the safest and most efficient location flanges touch the side framing. for the fireplace, you must take into consideration 4. Check the level of the fireplace and shim with the following guidelines: sheet metal if necessary. 1. The location must allow for proper clearances 5. Before securing fireplace to pr

Summary of the content on the page No. 6

MANTELS Firea lp ce ins Taa ll Tion A mantel may be installed if desired (see Figure 4). Continued Woodwork such as wood trims, mantels or any other HEARTH ExTENSION combustible material projecting from the front face A hearth extension projecting a minimum of 20" must not be placed within 12" of the fireplace open- in front of and a minimum of 12" beyond each ing. Combustible materials above 12" and projecting 1 side of the fireplace opening is required to protect more than 1 / " from th

Summary of the content on the page No. 7

VenTing insT alla Tion LINEAL GAIN PART NO. DESCRIPTION GAIN OPTIONAL OUTSIDE AIR KIT 1 Georgian Fireplace 66 / "  (MODEL AK4/AK4F) 12-12DM 5 Pipe Section 10 / " 8 The installation of an outside air kit should be per- 12-12HT formed during the rough framing of the fireplace 18-12DM 5 Pipe Section 16 / " 8 due to the nature of it's location. Outside combus- 18-12HT tion air is accessed through a vented crawl space 24-12DM 5 (AK4F) or through a sidewall (AK4). Pipe Section 3 / " 8 24-12HT 36-

Summary of the content on the page No. 8

2. Chimney weight above offset rests on return VenTing insT alla Tion elbow. Straps must be securely nailed to rafters Continued or joists (see Figure 8, details a and b). USING ELBOW OFFSETS (30E-12DM) 3. Maximum length of pipe between supports 1. To achieve desired offset, you may install (return elbow or 12S-12DM) is 6' of angle combinations of 12", 18", 24", 36" and 48" run. Maximum of two 6' angle run sections length of double wall pipe (see offset chart per chimney system (see Figu

Summary of the content on the page No. 9

PENETRATING THE ROOF VenTing insT alla Tion To maintain a 1" clearance to the pipe on a roof Continued with a pitch, a rectangular opening must be cut. 1. Determine the center point through which the pipe will penetrate the roof. 2. Determine the center point of the roof. Pitch Screws is the distance the roof drops over a given B span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" one measure horizontally down from the roof rafters. 3. Use the roof opening chart (Figu

Summary of the content on the page No. 10

VenTing insT alla Tion CAUTION: Do not seal open- Continued ings on the rooftop flashing. Fol- Storm low the installation instructions Overlap Collar Shingles Top provided with the termination Flashing and Sides Only being used. Cone Nail Only RTL-10D Outer Stainless Perimeter Level of Inner Flue of Flashing Flue Gas Pipe Outlet Secure Termination to Outer Waterproof Pipe with 3 Caulking Underlap Screws Storm Shingles Collar at Bottom Flashing Figure 13 - Flashing Installation

Summary of the content on the page No. 11

3. Run a 1/2" black iron gas line into the fireplace VenTing insT alla Tion through the rear at gas line conduit sleeve (if Continued using a raised platform, add height). Provide 10 FOOT RULE sufficient gas line into fireplace chamber for All flue gas outlet chimney terminations must fitting connection (see Figure 19). Note: Secure incoming gas line to wood framing to extend a minimum of 3 feet in height above the highest point where it passes through the roof and provide rigidity for th

Summary of the content on the page No. 12

opTional gas ine l glass door insT alla Tion insT alla Tion Continued IMPORTANT: Install glass door frame before installing glass CAUTION: All gas piping door. and connections must be tested for leaks after the installation INSTALLING DOOR FRAMES is completed. After ensuring 1. Remove screws from smoke shelf (see that the gas valve is on, apply Figure 20). soap and water solution to all 2. Mount top door frame and secure with screws removed in step 1. connections and joints. Bubbles

Summary of the content on the page No. 13

glass door opera Tion and insT alla Tion MainTenance Continued guidelines INSTALLING GLASS DOORS GLASS DOORS Spring clips have been installed but some adjust- Glass doors are optional with the fireplace. When ments may be needed. If doors do not close properly fireplace is in operation, doors must be fully or do not appear straight, see Door Adjustment. opened or fully closed position only or a fire hazard 1. With bi-fold doors completely folded, insert may be created (see Figure 24). bot

Summary of the content on the page No. 14

opera Tion and Damper MainTenance Weight uidelines g Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water. Do not use any abrasive material To Close to clean glass. Do not clean glass with any cool Damper water if glass is still hot from the fire and smoke. A gas line or gas log lighter may be installed for the purpose of installing a vented or vent-free deco- rative gas appliance incorporating an automatic shutoff device and complying with the Standa

Summary of the content on the page No. 15

replaceMenT p ar Ts HERRINGBONE BRICK LINER Bottom Front Brick Refractory 111509-01 - VG42H Models 111509-02 - G42H Models STANDARD BRICK LINER 111515-01 - VG50H Models Bottom Front Brick Refractory 111515-02 - G50H Models 111425-01 - VG42 Models Bottom Rear Brick Refractory 111425-02 - G42 Models 111510-01 - VG42H Models 111430-01 - VG50 Models 111510-02 - G42H Models 111430-02 - G50 Models 111512-01 - VG50H Models Bottom Rear Brick Refractory 111512-02 - G50H Models 111426-01 - VG42 Models

Summary of the content on the page No. 16

accessories OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION - AK-4 PN 01576 BI-FOLD GLASS DOOR STORM COLLAR - SC2-1 BDG42 - 42" Black Finish BDG42B - 42" Brushed Brass Finish BDG42P - 42" Platinum Finish FIRESTOP SPACER BDG42PB - 42" Polished Brass Finish FS-10 BD50 - 50" Black Finish BD50B - 50" Brushed Brass Finish BD50P - 50" Platinum Finish BD50PB - 50" Polished Brass Finish ROOF FLASHING V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch DOUBLE WALL PIPE - 12-12DM, 18-12DM,


Alternative user manuals
# User manual Category Download
1 Desa (V)368ST User manual Indoor Fireplace 0
2 Desa (V)B36L User manual Indoor Fireplace 0
3 Desa (V)C36 User manual Indoor Fireplace 0
4 Desa (V)C36H User manual Indoor Fireplace 1
5 Desa (V)B36LI User manual Indoor Fireplace 0
6 Desa (V)C36I User manual Indoor Fireplace 1
7 Desa (V)B36I User manual Indoor Fireplace 1
8 Desa (V)C36L User manual Indoor Fireplace 0
9 Desa (V)B36 User manual Indoor Fireplace 4
10 Desa (V)C36LH User manual Indoor Fireplace 0
11 Desa (V)C36LI User manual Indoor Fireplace 0
12 Desa (V)CB36N(E) User manual Indoor Fireplace 0
13 Desa (V)CB36P(E) User manual Indoor Fireplace 0
14 Desa (V)DVF36 User manual Indoor Fireplace 2
15 Desa (V)G36 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1