Westinghouse MA7200-4001/2-N1 user manual

User manual for the device Westinghouse MA7200-4001/2-N1

Device: Westinghouse MA7200-4001/2-N1
Category: Water Pump
Manufacturer: Westinghouse
Size: 0.83 MB
Added : 8/31/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Westinghouse MA7200-4001/2-N1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Westinghouse MA7200-4001/2-N1.

For your convenience

If looking through the Westinghouse MA7200-4001/2-N1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Westinghouse MA7200-4001/2-N1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Westinghouse MA7200-4001/2-N1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Westinghouse MA7200-4001/2-N1 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Westinghouse MA7200-4001/2-N1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Westinghouse MA7200-4001/2-N1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MA7200 PLUS INVERTER
SERIES
PUMP Quick Start Manual
1 to 2 HP
Models- MA7200-2001/2-N1 (230V)
&
MA7200-4001/2-N1 (460V)

th
Rev. 1.3 - May 27 2008

Summary of the content on the page No. 2

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ Quick Start Guide for Pump Applications This guide is to simplify the start up of the MA7200 PLUS Inverter series, 1 to 2 HP, for pump applications. It is not intended to replace the MA7200 PLUS Installation and Operation Manual, and the user is urged review this manual. There are three methods of control or combinations thereof that that m

Summary of the content on the page No. 3

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ Step 4 - Check Pump Motor Operation • Enter 10.00Hz for the frequency reference and set parameter Sn-08 =1 to disable Reverse Direction operation. Note: The output from the inverter is displayed in Hz as factory default. If desired, the output may be displayed in per cent (%) of full speed. (see appendix) to ; 0 1 - Press the key twice

Summary of the content on the page No. 4

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ • Press the RUN key, and check the pump direction of rotation. If the direction is not correct, press the STOP key and wait until the motor has come to a complete STOP. Next, power down the inverter. Danger After the power has been turned OFF, wait at least 5 minutes until the charge indicator extinguishes completely before touchin

Summary of the content on the page No. 5

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ ______________________________________________________________ 5 TECO – Westinghouse Motor Company

Summary of the content on the page No. 6

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ • After the method of control has been selected, if external control wiring is required, (e.g. external analog) power pown the inverter before removing any covers or making any connections. In the following pages are wiring examples for Start / Stop, E-Stop, Restart, and Analog Connections. Danger After the power has been t

Summary of the content on the page No. 7

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ DIGITAL INPUT / OUTPUT terminal connections ( 1 – 2 HP ) Fig’s 2a, 2b, and 2c below show the control terminal connections for input control functions. The connections shown are typical and the user is referred to the MA7200 Manual if additional information is required. Fig. 2d shows an example for the use of the Fault Output Relay.

Summary of the content on the page No. 8

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ ANALOG INPUT terminal connections ( 1 – 2 HP ) Fig’s 3a,3b, and 3c.show the various analog input schemes that can be used to control the output frequency and thus the speed of the pump motor when External Analog is selected by Sn-05 in Step 5. Only one method may be used as the input source with Fig. 3a Potentiometer In

Summary of the content on the page No. 9

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ MA7200 PLUS BLOCK DIAGRAM Fig. 4 is an overall basic electrical connection diagram for MA7200 PLUS inverters rated 1 to 2 HP. It is used in conjunction with the other sections of this guide to give the user the ability to successfully start up a Pump application. More detailed information is available in the MA7200 PLUS Manual to whic

Summary of the content on the page No. 10

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ Appendix A- Changing display to read output speed in percent (%) of full speed. The display is factory defaulted to show the inverter output frequency in Hz. If desired, the display can be changed to show the output frequency as a percentage of full speed. To do this parameter Cn-28 must be changed from (00000) t

Summary of the content on the page No. 11

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual _______________________________________________________________ Appendix B - Removing the LCD Digital Operator and Inverter Cover(s) ______________________________________________________________ 11 TECO – Westinghouse Motor Company

Summary of the content on the page No. 12


Alternative user manuals
# User manual Category Download
1 Westinghouse MA7200-2001/2-N1 User manual Water Pump 2
2 Edelbrock 25-4066 User manual Water Pump 0
3 A.O. Smith Century Pool & Spa Motor User manual Water Pump 156
4 Agilent Technologies Quaternary Pump 1100 Series User manual Water Pump 33
5 Aero Mist 50 Series User manual Water Pump 0
6 Amtrol GUARDIAN CP DC2 User manual Water Pump 3
7 Aqua Flo A Series User manual Water Pump 12
8 Annovi Reverberi RKA 1750 rpm N Version User manual Water Pump 60
9 Annovi Reverberi RKA 1750 rpm E Version 1-1/8" User manual Water Pump 22
10 Annovi Reverberi RKV 3400 rpm D Version - 1" User manual Water Pump 34
11 Annovi Reverberi HRM-A User manual Water Pump 17
12 Annovi Reverberi RK 1450 rpm N Version User manual Water Pump 46
13 Aqua Flo Therma-Flo EHT User manual Water Pump 2
14 AquaPRO TSC130 PRO User manual Water Pump 19
15 AquaPRO GPH550PRO User manual Water Pump 11