STA-RITE DURA-GLAS IITM P4R6F3-152 user manual

User manual for the device STA-RITE DURA-GLAS IITM P4R6F3-152

Device: STA-RITE DURA-GLAS IITM P4R6F3-152
Category: Water Pump
Manufacturer: STA-RITE
Size: 0.39 MB
Added : 3/19/2014
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for STA-RITE DURA-GLAS IITM P4R6F3-152. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with STA-RITE DURA-GLAS IITM P4R6F3-152.

For your convenience

If looking through the STA-RITE DURA-GLAS IITM P4R6F3-152 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual STA-RITE DURA-GLAS IITM P4R6F3-152 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual STA-RITE DURA-GLAS IITM P4R6F3-152 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
STA-RITE DURA-GLAS IITM P4R6F3-152 User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual STA-RITE DURA-GLAS IITM P4R6F3-152 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to STA-RITE DURA-GLAS IITM P4R6F3-152. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TM
DURA-GLAS II CENTRIFUGAL PUMPS
WITH INTEGRAL TRAP
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
P4R and P4RA Series MODELS
HP
3/4 P4R62D3-150 P4R6D3-150
1 P4R62E3-151 P4R6E-151L P4R6E3-151
1-1/2 P4R62F3-152 P4R6F-152L P4RA6F-151L P4R6F3-152
1-3/4 P4RAA6F-177L
2 P4R62G3-153 P4R6G-153L P4RA6G-152L P4RA6GC-150 P4R6G3-153
2-1/2 P4RAA6G-153L
3 P4R6H3-154
This manual should be furnished to
the end user of this pump; its use will
reduce service calls and chance of
injury and will lengthe

Summary of the content on the page No. 2

‘P4R’ and ‘P4RA’ SERIES II PUMP WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘P4R’ and ‘P4RA’ Series II Self-priming Centrifugal pumps: • Are designed for use with swimming pools or as centrifugal pumps. • Are excellent performers; durable, reliable. Table of Contents Safety Instructions ........................................................................................3 Installation......

Summary of the content on the page No. 3

READ AND FOLLOW SAFETY INSTRUCTIONS! IMPORTANT SAFETY This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert INSTRUCTIONS to the potential for personal injury. Always follow basic safety pre- cautions with this equipment, in- warns about hazards that will cause death, serious personal cluding the following. injury, or major property damage if ignored. To reduce the risk of warns about hazards that can

Summary of the content on the page No. 4

Figure 1 INSTALLATION Only qualified, licensed personnel should install pump and wiring. Pump mount must: Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Allow pump suction inlet height to be as close to water level as possible. Allow use of short, direct suction pipe (To reduce friction losses). Allow for gate valves in suction and discharge piping. Have adequate floor drainage to prevent flooding. Be protected from excess moisture. Allow ad

Summary of the content on the page No. 5

Piping: Use at least 2" IPS PVC (51mm) pipe. Increase size if a long run is needed. To avoid strains on the pump, support both suction and discharge pipes inde- pendently. Place these supports near the pump. To avoid a strain left by a gap at the last connection, start all piping at the pump and run pipe away from the pump. Never use a suction pipe smaller than pump suction connection. To avoid airlocking, slope suction pipe slightly upward toward the pump. NOTICE: To prevent flooding when remo

Summary of the content on the page No. 6

ELECTRICAL Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Ground Fault Circuit Interrupter (GFCI) tripping indicates an electrical problem. If GFCI trips and will not reset, have a qualified electrician inspect and repair electrical system. Hazardous voltage. Exact

Summary of the content on the page No. 7

OPERATION NEVER run pump dry. Running pump dry may damage seals, causing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. 4. NEVER tighten or loosen clamp while pump is operating! If pump is being pressure tested, be sure pressure has been released be- fore removing trap cover. Do not block pump suction. To do so wi

Summary of the content on the page No. 8

Draining Pump 1. Pump down water level below all inlets to the pool. To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining pump. 2. Remove trap cover and use low pressure air to blow accumulated water from the piping system. Lugs have been provided on the trap lid to use a lever or pry bar for loosening. 3. Cap inlet piping after draining to keep water out of the pipes. 4. To prevent pump from freezing, remove trap cover and drain the tank body through the

Summary of the content on the page No. 9

PUMP SERVICE Pump should only be serviced by qualified personnel. Be sure to prime pump (Pg. 7) before starting. Before removing clamp or trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. 4. NEVER tighten or loosen clamp while pump is operating! To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before working on pump or motor. Aside from lubricating trap cover “O” Ring,

Summary of the content on the page No. 10

Pump Reassembly/Installing New Seal 1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer edge of “O” Ring with small amount of liquid detergent; press ceramic seat into heat sink insert firmly and squarely with finger pressure (Fig. 5). 2. If ceramic seat will not locate properly, remove it, place face up on bench and reclean cavity. Ceramic seat should now locate. 3. If seat still will not locate properly, place a cardboard washer over the polished face and use a piece o

Summary of the content on the page No. 11

NOTICE: To prevent leaks around seal, do not install “O” Ring by mounting on heat sink insert and then pushing insert into seal plate cav- ity. “O” Ring will roll out of position and leak if it is mounted on insert first. 3. With thumbs near center of insert, line up screw slots in insert with screw holes in seal plate; push insert into seal plate cavity (Figure 9). 4. Replace two screws in insert and tighten (Figure 10). TROUBLESHOOTING GUIDE Read and understand safety and operating instruction

Summary of the content on the page No. 12

3 1 P4R and P4RA SERIES 2 DURA-GLAS II POOL PUMP 4 1 through 2-1/2 H.P. Models 5 6 8 1860 0795 16 9 7 17 24 10 11 15 18 12 23 13 14 20 21 19 22 REPAIR PARTS LIST Key Part Part No. Description Qty. No. 1 Motor 1 Chart at Right 2 #10-32 x 1/2” Screw 1 U30-692SS 3 Bonding Lug 1 U17-568 4 Water Slinger 1 C69-2 5 Seal Plate 1 C203-187P 6 “O” Ring 1 U9-228A 7 “O” Ring 1 U9-376 8 Insert 1 C3-186 9 #8-32 x 1/4” Screw 2 U30-401SS Parts are common to all models listed except as noted; 10 Shaft Seal 1 U109

Summary of the content on the page No. 13

3 P4R SERIES 1 2 DURA-GLAS II POOL PUMP 4 208-230/460V 3 Phase Models 5 6 8 1860 0795 16 9 7 17 24 10 11 15 18 12 Models P4R6D3-150 23 P4R6E3-151 P4R6F3-152 13 14 P4R6G3-153 20 P4R6H3-154 21 19 22 REPAIR PARTS LIST Key Part Part No. Description Qty. No. 1 Motor 1 Chart at Right 2 #10-32 x 1/2” Screw 1 U30-692SS 3 Bonding Lug 1 U17-568 4 Water Slinger 1 C69-2 5 Seal Plate 1 C203-187P 6 “O” Ring 1 U9-228A 7 “O” Ring 1 U9-376 8 Insert 1 C3-186 Parts are common to all models listed except as noted;

Summary of the content on the page No. 14

P4R SERIES 3 1 2 DURA-GLAS II POOL PUMP 4 200/400V 3 Phase Models 5 6 8 1860 0795 16 9 7 17 24 10 11 15 18 12 Models 23 P4R62D3-150 P4R62E3-151 13 14 P4R62F3-152 20 P4R62G3-153 19 21 22 REPAIR PARTS LIST Key Part Part No. Description Qty. No. 1 Motor 1 Chart at Right 2 #10-32 x 1/2” Screw 1 U30-692SS 3 Bonding Lug 1 U17-568 4 Water Slinger 1 C69-2 5 Seal Plate 1 C203-187P 6 “O” Ring 1 U9-228A 7 “O” Ring 1 U9-376 8 Insert 1 C3-186 9 #8-32 x 1/4” Screw 2 U30-401SS Parts are common to all models li

Summary of the content on the page No. 15

STA-RITE LIMITED WARRANTY Pumps, filters, skimmers, underwater lights (except bulbs), tion. Purchasers must pay all labor and shipping charges nec- accessories and fittings manufactured by Sta-Rite are war- essary to replace the product covered by this warranty. ranted to be free of defects in material and workmanship for Requests for warranty service must be made through the in- one (1) year from date of installation. stalling dealer. This warranty shall not apply to any product that has been s


Alternative user manuals
# User manual Category Download
1 STA-RITE DURA-GLAS IITM P4R62E3-151 User manual Water Pump 52
2 STA-RITE DURA-GLAS IITM P4R6D3-150 User manual Water Pump 7
3 STA-RITE DURA-GLAS IITM P4R62G3-153 User manual Water Pump 7
4 STA-RITE DURA-GLAS IITM P4R6E-151L User manual Water Pump 10
5 STA-RITE DURA-GLAS IITM P4R62F3-152 User manual Water Pump 5
6 STA-RITE DURA-GLAS IITM P4R6F-152L User manual Water Pump 1
7 STA-RITE DURA-GLAS IITM P4R6E3-151 User manual Water Pump 1
8 STA-RITE DURA-GLAS IITM P4R6G-153L User manual Water Pump 1
9 STA-RITE DURA-GLAS IITM P4RA6G-152L User manual Water Pump 8
10 STA-RITE DURA-GLAS IITM P4RA6F-151L User manual Water Pump 3
11 STA-RITE DURA-GLAS IITM P4R6G3-153 User manual Water Pump 0
12 STA-RITE DURA-GLAS IITM P4RAA6F-177L User manual Water Pump 2
13 STA-RITE DURA-GLAS IITM P4RAG6C-150 User manual Water Pump 0
14 STA-RITE DURA-JET JSADL User manual Water Pump 12
15 STA-RITE DURA-JET JSACL User manual Water Pump 0
16 Edelbrock 25-4066 User manual Water Pump 0
17 A.O. Smith Century Pool & Spa Motor User manual Water Pump 156
18 Agilent Technologies Quaternary Pump 1100 Series User manual Water Pump 33
19 Aero Mist 50 Series User manual Water Pump 0
20 Amtrol GUARDIAN CP DC2 User manual Water Pump 3