SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B user manual

User manual for the device SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B

Device: SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B
Category: Water Pump
Manufacturer: SSI America
Size: 0.77 MB
Added : 3/19/2014
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B.

For your convenience

If looking through the SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B User manual - Online PDF
Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to SSI America BINARY SOLVENT DELIVERY MODULE 90-2581 REV B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 13

2.7 Preparation for Storage or Shipping 2.7.1 Isopropanol Flush Disconnect the outlet tubing from the pump. Place the inlet filter in isopropanol. Use a syringe to draw a minimum of 50 ml through the pump. Pump a minimum of 5 ml of isopropanol to exit. Leave the inlet tubing connected to the pump. Place the inlet filter in a small plastic bag and attach it to the tubing with a rubber band. Plug the outlet port with the shipping plug or leave a length of outlet tubing on the pump or c

Summary of the content on the page No. 14

3. OPERATION 3.1 Pump Front Panel Controls and Indicators 3.1.1 Control Panel 3.1.1.1 Digital Display The 3-digit display shows the pump flow rate (mL/min), system pressure (psi), or the set upper or lower pressure limit (psi) when operating. Choice of display is selected with the MODE key. 3.1.1.2 Digital Display Pump Keypad When pressed, this button increases the flow rate. ∆ When pressed, this button decreases the flow rate. ∇ Use this button to cycle through the four

Summary of the content on the page No. 15

3.1.1.3 Status LEDs ml/min When lit, the digital display shows flow rate in mL/min. PSI When lit, the digital display shows system pressure in psi. HI PR When lit, the display shows the user-set upper pressure limit in psi. LO PR When lit, the display shows the user-set lower pressure limit in psi. RUN Lights to indicate that the pump is running. FAULT Lights when a fault occurs and stops the pump. 3.1.1.2 Power-up Configuration Non-volatile Memory Reset: If t

Summary of the content on the page No. 16

Align Refill Switch Mode: The signal that initiates the refill phase can be displayed during power-up by pressing and holding the PRIME and the UP-ARROW buttons when the power is switched on. Release the buttons when the display displays "rFL". When the slotted disk allows the light beam to pass from the emitter to the detector on the slotted optical switch a pulse will be generated which signals the beginning of refill. When this pulse occurs the three horizontal segments displ

Summary of the content on the page No. 17

4. THEORY OF OPERATION 4.1 Pump Mechanical Operation 4.1.1 Liquid System Flow Path The flow path of the Binary Solvent Delivery Module starts at the inlet reservoir filter passes through the inlet check valve, then through the pump head, and finally exits through the outlet check valve. 4.1.2 Pump Cycle The pump cycle consists of two phases, the pumping phase, when fluid is metered out of the pump at high pressure, and the refill phase, when fluid is rapidly drawn into the pump. Duri

Summary of the content on the page No. 18

4.2 Electronic Control 4.2.1 Microprocessor Control The pump is controlled by hybrid microprocessor circuitry which (1) provides control signals to the motor drive circuitry, (2) interfaces with the keyboard/display, (3) receives signals from the refill flag, and (4) provides external input/output (RS-232) interfacing. Firmware programming is stored in an EPROM. An eccentric cam provides refill in a fraction of the full cam cycle. The remaining revolution of the cam provides piston d

Summary of the content on the page No. 19

Motor Stall Detector press the DOWN-ARROW button and the display will display "OFF". To exit this mode and store the current setting in non-volatile memory, press the RUN/STOP button. The Motor Stall Detector uses a timer to determine if the camshaft has stopped turning or if the refill switch is defective. The timer begins timing after the pump accelerates or decelerates to its set point flow rate. If the Motor Stall Detector has been enabled, and the camshaft stops turning or the

Summary of the content on the page No. 20

5. MAINTENANCE Cleaning and minor repairs of the Binary pump can be performed as outlined below. NOTE: Lower than normal pressure, pressure variations, or leaks in the pumping system can all indicate possible problems with the piston seal, piston, or check valves. Piston seal replacement could be necessary after 1,000 hours of running time. See Section 5.2.3. 5.1 Filter Replacement 5.1.1 Inlet Filters Inlet filters should be checked periodically to ensure that they are clean and no

Summary of the content on the page No. 1






















Binary Solvent Delivery Module
Dual Series-III Pumps with Serial PC and Voltage Control


Operator's Manual


90-2581 rev B







Scientific Systems, Inc. 349 N. Science Park Road State College, P
16803

Summary of the content on the page No. 2

Summary of the content on the page No. 3

1. INTRODUCTION This operator's manual contains information needed to install, operate, and perform minor maintenance on the Binary Solvent Delivery Module. The figures below are for reference of items described in the manual. Power “T” With Switch Outlet Left Right Drawer Drawer Control Keypads Prime Purge Outlet Valves Filters Cooling Power Fan Entry RS-232 Auxiliary I/O Serial Ports Voltage Control, etc. 1-1

Summary of the content on the page No. 4

1.1 Description of the Binary Solvent Delivery Module The system consists of two Series III high performance metering pumps, in a compact package with pulse dampener and an off-line pressure transducer. The pumps use a drawer system for easy access to internal components for troubleshooting & service. These features allow for: Fast & easy setup: Two inlet connection (from solvent reservoirs) One outlet connection (to injector) All connections accessible from front panel

Summary of the content on the page No. 5

Flow adjustment in 0.01 ml increments, from 0.01 to 10.00 ml/min with a precision of 0.2% RSD (10mL/min heads) • Microprocessor advanced control • Digital stepper motor design to prevent flow rate drift over time and temperature • Back panel RS232 serial communications port for complete control and status monitoring • Remote analog inputs (e.g. voltage) to control flow rate 1.1.2 Wetted Pump Materials Pump heads, check valve bodies, and tubing are made out Stainless Steel or PEE

Summary of the content on the page No. 6

1.1.4 Self-Flush and Seal Life It is recommended that the Self Flush feature be used to improve seal life in a number of applications. In particular, (as stated above) if pumping Buffers, Acids/Bases or any inorganic solution near saturation, the pump should utilize the Self Flush feature. With every piston stroke, an extremely thin film of solution is pulled back past the seal. If this zone is dry (without use of Self Flush), then crystals will form with continuous operation, which

Summary of the content on the page No. 7

1.2 Specifications for the Binary Solvent Delivery Modules Flow Rates ............0.000 to 5.000 mL/min for 5mL/min heads 0.00 to 10.00 mL/min for 10mL/min heads Pressure ................0 to 6,000 p.s.i. for SS pump heads, 0 to 5,000 p.s.i. for PEEK™ heads, Pressure Accuracy… . ± 1% of full-scale pressure Pressure Zero Offset. . ± 2 p.s.i. Flow Accuracy ........ ± 2% for a flow rate of 0.20 mL/min and above. Flow Precision .......0.2% RSD Dimensions ............9" high x 10.5"

Summary of the content on the page No. 8

2. INSTALLATION 2.1 Unpacking and Inspection Prior to opening the shipping container, inspect it for damage or evidence of mishandling. If it has been damaged or mishandled, notify the carrier before opening the container. Once the container is opened, inspect the contents for damage. Any damage should be reported to the carrier immediately. Save the shipping container. Check the contents against the packing list. 2.2 Location/Environment The preferred environment for the Binary Solve

Summary of the content on the page No. 9

SELF-FLUSH PUMP Connect wash solution inlet and Connect pump inlet tubing as outlet tubing shown. (opaque) to the flush housing as Make sure ferrule is in the shown. correct Make sure ferrule is in the correct position. position. Screw syringe on luer fitting. Insert wash outlet tubing end Ensure inlet line filter is into clear adapter. submersed into solvent. Attach syringe to Prime-Purge valve. Open Prime-Purge valve by turning kn

Summary of the content on the page No. 10

2.4 Electrical Connection The system utilizes Universal Switching Power Supply, and will accept voltages from 90 – 260 VAC, 50-60 Hz. WARNING: Do not bypass the safety ground connection as a serious shock hazard could result. 2.5 Solvent Preparation Proper solvent preparation will prevent a great number of pumping problems. The most common problem is bubble formation, which may affect the flow rate consistency. Aside from leaky fittings, the problem of bubble formation ari

Summary of the content on the page No. 11

2.5.2 Cavitation Cavitation occurs when inlet conditions restrict the flow of solvent and vapor bubbles are formed during the inlet stroke. The key to preventing cavitation is to reduce inlet restrictions. The most common causes of inlet restrictions are crimped inlet lines and plugged inlet filters. Inlet lines with tubing longer than 48" (120 cm) or with tubing of less than 0.085" (2 mm) ID may also cause cavitation. Placing the solvent reservoirs below the pump level also promotes

Summary of the content on the page No. 12

2.6.2 Self-Flush Solution Self-flush heads require 250-500 mL of flushing solution. See section 1.1.4 for self-flush solution recommendations. A pH indicator that will indicate the concentration of salts in the solution is recommended as a reminder to change the solution. This flush solution should be replaced with a fresh solution weekly to avoid frequent pump maintenance. 2.6.3 Inlet Tubing and Filters The table below shows the inlet tubing and filter used in the Binary Solvent De


Alternative user manuals
# User manual Category Download
1 Edelbrock 25-4066 User manual Water Pump 0
2 A.O. Smith Century Pool & Spa Motor User manual Water Pump 156
3 Agilent Technologies Quaternary Pump 1100 Series User manual Water Pump 33
4 Aero Mist 50 Series User manual Water Pump 0
5 Amtrol GUARDIAN CP DC2 User manual Water Pump 3
6 Aqua Flo A Series User manual Water Pump 12
7 Annovi Reverberi RKA 1750 rpm N Version User manual Water Pump 60
8 Annovi Reverberi RKA 1750 rpm E Version 1-1/8" User manual Water Pump 22
9 Annovi Reverberi RKV 3400 rpm D Version - 1" User manual Water Pump 34
10 Annovi Reverberi HRM-A User manual Water Pump 17
11 Annovi Reverberi RK 1450 rpm N Version User manual Water Pump 46
12 Aqua Flo Therma-Flo EHT User manual Water Pump 2
13 AquaPRO TSC130 PRO User manual Water Pump 19
14 AquaPRO GPH550PRO User manual Water Pump 11
15 Aurora of America Aurora Corp. of America442 User manual Water Pump 4