Rheem RTG2-53(PVN)(PVP)(XN)(XP) user manual

User manual for the device Rheem RTG2-53(PVN)(PVP)(XN)(XP)

Device: Rheem RTG2-53(PVN)(PVP)(XN)(XP)
Category: Water Heater
Manufacturer: Rheem
Size: 4.08 MB
Added : 3/15/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Rheem RTG2-53(PVN)(PVP)(XN)(XP). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Rheem RTG2-53(PVN)(PVP)(XN)(XP).

For your convenience

If looking through the Rheem RTG2-53(PVN)(PVP)(XN)(XP) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Rheem RTG2-53(PVN)(PVP)(XN)(XP) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Rheem RTG2-53(PVN)(PVP)(XN)(XP) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Rheem RTG2-53(PVN)(PVP)(XN)(XP) User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Rheem RTG2-53(PVN)(PVP)(XN)(XP) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Rheem RTG2-53(PVN)(PVP)(XN)(XP). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

C
N
E
G
R
I
T
Use & Care Manual
With Installation Instructions for the Installer
Indoor and Outdoor Gas
Tankless Water Heater
!
Warning: This water heater is not suitable
for use in manufactured (mobile) homes!
The purpose of this manual is twofold: one, to provide the installer with
the basic directions and recommendations for the proper installation and
adjustment of the water heater; and two, to the owner–operator, to
explain the features, operation, safety precautions, maintenance and
troubl

Summary of the content on the page No. 2

Safety Information FOR YOUR RECORDS Safety Precautions. . . . . . . 3–6 Write the model and serial numbers here: LP Gas Models . . . . . . . . . . . 5 # # Installation Instructions You can find them on a label on the appliance. Location, Outdoor. . . . . . . . . . 7 Staple sales slip or cancelled check here. Location, Indoor . . . . . . . . . 8, 9 Proof of the original purchase date is needed to obtain service under the warranty. Venting . . . . . . . . . . . . . . 10-15 Water Connections. . .

Summary of the content on the page No. 3

IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and money. Pay particular attention to the Safety Instructions. Failure to follow these warnings could result in serious bodily injury or death. Should you have problems understanding the instructions in this manual, or have any questions, STOP, and get help from a qualified service technici

Summary of the content on the page No. 4

IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING. ! DANGER! WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of a water heater’s remote control. Water temperatures above 125°F (52°C) can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. Time/Temperature Relationship in Scalds ! DANGER Water Temperature Time To Produce a Serious Bu

Summary of the content on the page No. 5

DANGER! NATURAL GAS AND LIQUEFIED PETROLEUM MODELS Both LP and natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier. Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity, can also hide or camouflage a gas leak. ● Water heaters utilizing LP gas are different Notice: If a gas leak is

Summary of the content on the page No. 6

IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING. ! WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury or loss of life. FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that water heaters must be braced, anchored or strapped to resist falling or horizontal displacement due to earthquake motions. For water heaters up to 52 gallon cap

Summary of the content on the page No. 7

Installing the (OUTDOOR) water heater: This water heater must be installed in accordance with these instructions, local codes, utility company requirements and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400 North Capitol Street Northwest, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269

Summary of the content on the page No. 8

Installing the (INDOOR) water heater : This water heater must be installed in accordance with these instructions, local codes, utility company requirements and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400 North Capitol Street Northwest, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269

Summary of the content on the page No. 9

C N E G R I T Proper operation of the water heater requires air for combustion and ventilation. Provisions for combustion and ventilation air must comply with referenced codes and standards. Combustion and Ventilation Air (Indoor Water Heater Only) NOTICE: If the water heater is installed in Buildings of unusually tight construction an unconfined space within a building of shall have the combustion and ventilation conventional frame, masonry or metal air supplied from outdoors, or a freely const

Summary of the content on the page No. 10

Installing the (INDOOR) water heater: The water heater must be installed with a 3” diameter UL approved Category III Stainless Steel appliance vent pipe and an appropriate adapter. Venting DANGER: Failure to install the appliance vent The installation of venting must comply span should be no more than five (5) feet adapter and properly vent with national codes, local codes and the (1.5 m). Support isolation hanging bands the water heater to the vent manufacturer’s instructions. should be used. D

Summary of the content on the page No. 11

Venting Through Closed Spaces If the vent piping passes through a closed space, a minimum clearance of 8” (20 cm) when installed horizontally or 6” (15 cm) when installed 1/4" per foot Wall Thimble vertically should be maintained between the vent pipe and combustibles downward slope and noncombustibles. Be sure to follow local codes and vent manufacturer’s installation instructions. Fire Stop For maintenance and inspection purposes, the following access panels are required. Vent Pipe ● Two (

Summary of the content on the page No. 12

D E B V V L Installing the water heater: A AIIR R S SU UP PP PL LY Y IIN NL LE ET T A AR RE EA A W WH HE ER RE E T TE ER RM MIIN NA AL L IIS S N NO OT T P PE ER RM MIIT TT TE ED D V V VE EN NT T T TE ER RM MIIN NA AL L X Horizontal Vent Terminal Location The following information should be used for determining the proper location of the vent terminal for indoor and outdoor tankless water heaters. 1 2 2 C Ca an na ad diia an n IIn ns stta alllla attiio on ns s U US S IIn ns stta alllla

Summary of the content on the page No. 13

Outdoor Water Heater Additional Considerations Do NOT install vent terminal under any patio or deck. To help prevent moisture from freezing on walls and under Caulk eaves, do not locate vent terminal on the side of a building with Rising moisture will collect under eaves prevailing winter winds. (1.8 m) To help prevent water lines from freezing, do not locate vent 6' If soffit vent is too close, 6' (1.8 m) terminal on the side of a building with prevailing winter winds. block off and ins

Summary of the content on the page No. 14

Installing the (INDOOR) water heater: Vent Horizontal Wall Thimble Installation Inner Thimble Outer Thimble An approved 3“ (7.6 cm) Vent Horizontal sheathing is particle board or other Section Section Wall Thimble must be used. composite material. Use four (4) #10x1-1/4” wood screws for plywood, solid wood The Wall Thimble requires mechanical sheathing or members. Use suitable support from the wall sufficient to support any masonry anchors when passing through incidental loads on the system. If

Summary of the content on the page No. 15

Vertical Vent Termination Location The location of the vent terminal depends on the following Small (6” min) (15 cm) section of vent minimum clearances and considerations (see diagram at left): Elbow 2 Minimum twelve (12) inches (30 cm) above roof. Minimum twelve (12) inches (30 cm) above anticipated snow level. Maximum twenty-four (24) inches (60 cm) above roof level Vent Pipe Min. 12" (30 cm) without additional support for vent. Through Roof 1 Above Roof Four (4) feet (1.2 m) from any gable,

Summary of the content on the page No. 16

Installing the water heater: Mounting the Water Heater Make sure the location of the appliance allows Using a wood screw and a washer, affix the CAUTION: for easy access and operation. lower bracket to the wall (Left and Right). Reinforcement of the wall is Repeat to affix the top bracket. Wall studs should be utilized when mounting required in case the wall is the water heater to the wall. Alternately, a The brackets can be adjusted to change the not strong enough to hold the appliance. suitabl

Summary of the content on the page No. 17

Water Supply Connections, continued Notice: If the water flow resistance of a Be sure to connect the water inlet and the CAUTION: This water shower head is too high, the burner in the hot water outlet as shown on the water heater must only be used with water heater will fail to ignite. Keep the heater. If reversed, the water heater will the following water supply shower head clean from debris that could not function. system conditions: cause additional pressure drop. ● With clean, potable water

Summary of the content on the page No. 18

Installing the water heater: Relief Valve A new pressure relief valve, complying ● The end of the discharge line should not with the Standard for Relief Valves and be threaded or concealed and should be Drain Valve shown on Automatic Gas Shut-Off Devices for Hot protected from freezing. No valve of any right without Water Supply Systems, ANSI Z21.22/ type, restriction or reducer coupling should tubing (barb CSA 4.4, must be installed at the hot water be installed in the discharge line. fitting

Summary of the content on the page No. 19

WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Gas Supply The supplied Manual Gas Appliance Shutoff Do not use excessive force (over 31.5 ft lbs. Valve must be installed at the gas connection of [42.7 Nm]) in tightening the pipe, particularly if the water heater at the time of installation (see teflon pipe compound is used, as the unit may Manu

Summary of the content on the page No. 20

PRIORITY °F POWER ON/OFF Installing the Main Remote Control: WARNING: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, Canadian Electrical Code, CSA C22.1 Part 1. Remote Control Installation One (1) remote control is provided with the may be subjected to oil and/or steam NOTICE: The provided water heater. Additional remote controls may from cookin


Alternative user manuals
# User manual Category Download
1 Rheem 000 BTU User manual Water Heater 107
2 Rheem 100 User manual Water Heater 105
3 Rheem 000 BTU max User manual Water Heater 18
4 Rheem 120 User manual Water Heater 83
5 Rheem 000 - 180 User manual Water Heater 39
6 Rheem 11 User manual Water Heater 6
7 Rheem 175 User manual Water Heater 1
8 Rheem 110 User manual Water Heater 7
9 Rheem 130 User manual Water Heater 6
10 Rheem 19 User manual Water Heater 9
11 Rheem 208 User manual Water Heater 0
12 Rheem 136-1826 User manual Water Heater 8
13 Rheem 115 User manual Water Heater 2
14 Rheem 199 User manual Water Heater 6
15 Rheem 240 User manual Water Heater 4
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6