Redring 1070800E user manual

User manual for the device Redring 1070800E

Device: Redring 1070800E
Category: Water Heater
Manufacturer: Redring
Size: 0.08 MB
Added : 10/5/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Redring 1070800E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Redring 1070800E.

For your convenience

If looking through the Redring 1070800E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Redring 1070800E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Redring 1070800E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Redring 1070800E User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Redring 1070800E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Redring 1070800E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Trouble Shooting
All Models
Redring
SB Professional
On Wall Boiling Water Heater
Models:
1070800E 2.5 ltr
1070810E 5 ltr
1070815E 7.5 ltr
1070820E 10 ltr
1070825E 15 ltr
1070830E 20 ltr
1070835E 25 ltr
Page 1 of 8
Redring SB

Summary of the content on the page No. 2

Contents Subject Page General Product Operation......................................................................2 Spares Diagram and List.........................................................................3 Unit Dimensions.......................................................................................3 Problem Solving......................................................................................4 Tank Access.................................................................

Summary of the content on the page No. 3

Spare parts and diagrams for location and installation dimensions. Spare Parts 9b 1311056 Tap Assembly Ref Part No Description 10 1311082 Sensor (minimum water level) 1 1311010 Water Solenoid Valve 11 1311048 Probe (maximum water level) 2 1311044 Condenser Assembly 12 Steam Vent Outlet 3 Cold Water Inlet To Tank 4 1311043 Thermistor Steam Sensor 13 Maximum Water Level 5a Element & Tank Assembly 14 1310842 Power Cord & Plug Assembly 5b 1311032 Element Assembly 5 to 25 Litre 15a 1311045 Control Bo

Summary of the content on the page No. 4

Problem Solving Symtom Solution Unit filling to low level but not heating 1. Possible faulty PCB 2. Check Element 3. Check all wiring connections Unit not filling 1. Check top probe (No.11 page 3) and ensure that the probe is not in contact with tubing. Also check for scale build up. 2. Check solenoid valve (No.1 page 3) with multimeter set to K Ohms scale, it should read between 3.9 - 4.2. 3. Check water supply. 4. Turn pwer supply on then off to see if you can hear the “squirt” o

Summary of the content on the page No. 5

Tank access and replacing parts Task Operation Front cover removal 1. Turn power and water off 2. Drain unit via tap, be carefull of boiling water. 3. Remove the tap assy by unscrewing counter-clockwise 4. Undo self-tapping screws, 2 at top and 2 at bottom of case. Remove the cover by drawing towards you. Replace Solenoid 1. Directions as above in Cover Removal. 2. Disconnect wires to valve. 3. Disconnect the water fitting attached to valve. 4. Unscrew securing screws fixing va

Summary of the content on the page No. 6

Tank access and replacing parts con’t. Task Operation Replace Thermistor Steam Sensor 1. Directions as above in Cover Removal. 2. Remove PCB cover plate. 3. Remove the thermistor. 4. The probe end of the thermistor pushes into the condensor tube so that the tip just covers the hole drilled in the condensor tube. 5. Re-connect the sensor to the PCB at either NTC 1 or NTC 2, in any order. Condensor Tube Sensor Probe Page 6 of 8 Redring SB

Summary of the content on the page No. 7

Notes Page 7 of 8 Redring SB

Summary of the content on the page No. 8

Applied Energy Products Ltd, Morley Way, Peterborough. PE2 9JJ. England General enquiry Tel +44 (0) 1733 456789 Fax +44 (0) 1733 310606 Technical Hotline Tel +44 (0) 8709 000430 Fax +44 (0) 8709 000530 Sales/Spares Tel +44 (0) 8709 000420 Fax +44 (0) 8709 000520 Page 8 of 8 Redring SB


Alternative user manuals
# User manual Category Download
1 Redring 1070810E User manual Water Heater 3
2 Redring 1070820E User manual Water Heater 0
3 Redring 1070825E User manual Water Heater 0
4 Redring 1070815E User manual Water Heater 0
5 Redring 1070830E User manual Water Heater 0
6 Redring 1070835E User manual Water Heater 0
7 Redring AE125 User manual Water Heater 1
8 Redring AE115 User manual Water Heater 0
9 Redring DC3810 User manual Water Heater 0
10 Redring WS7 User manual Water Heater 4
11 A.O. Smith 000 User manual Water Heater 8
12 A.O. Smith 101 User manual Water Heater 3
13 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
14 A.O. Smith 104 Series User manual Water Heater 3
15 A.O. Smith 104 - 110 User manual Water Heater 6