Bosch Appliances 125B LP user manual

User manual for the device Bosch Appliances 125B LP

Device: Bosch Appliances 125B LP
Category: Water Heater
Manufacturer: Bosch Appliances
Size: 0.84 MB
Added : 12/6/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bosch Appliances 125B LP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bosch Appliances 125B LP.

For your convenience

If looking through the Bosch Appliances 125B LP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bosch Appliances 125B LP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bosch Appliances 125B LP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bosch Appliances 125B LP User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bosch Appliances 125B LP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bosch Appliances 125B LP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC
INSTANTANEOUS TYPE WATER HEATERS FOR USE WITH NATURAL AND
LIQUEFIED PETROLEUM GAS
MODEL 125B LP and 125B NG (Flow Modulated)
Suitable for heating potable water only
Not approved for space heating purposes
Intended for variable flow applications with steady cold water inlet temperatures only
WARNING
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or death.
FOR Y

Summary of the content on the page No. 2

This well engineered, gas water heater has all the fea- AquaStar 125B LP and 125B NG Specifications tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water Gas Input max.: 117,000 Btu/hr flows through the coils of the heat exchanger in the Aquastar. min.: 28,000 Btu/hr This same flow opens the gas valve, and the burners are ignited by the pilot flame. The heat exchanger coils absorb Water Connec

Summary of the content on the page No. 3

FRONT VIEW SIDE VIEW MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS MODEL 125B TOP (A) 12 " FRONT (B) 4 " BACK 0 " SIDES 4 " FLOOR (C) 12 " VENT DIAMETER 5 " AQUASTAR MODEL 125B 6 720 607 030 3

Summary of the content on the page No. 4

GENERAL RULES TO FOLLOW PROPER LOCATION FOR INSTALLING YOUR FOR SAFE OPERATION HEATER Carefully select the location of your new heater. For your 1. You should follow these instructions when you install your safety and for proper heater operation, you must provide an heater. In the United States: The installation must conform abundant supply of combustion air and a proper venting with local codes or, in the absence of local codes, the installation. National Fuel Gas Code ANSI Z223.1/NFPA 54. The

Summary of the content on the page No. 5

Air Vents 125B (10 ¾ X 10 ¾ in. each) Fig. 1 - Water heater drain plug WARNING: Flammable materials, gasoline, Air Vents 125B pressurized containers, or any other items or articles (5 ½ X 5 ½ in. each) that are potentially fire hazards must NOT be placed on or adjacent to the heater. The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids. Appliances located in confined spaces: The confined space must be provided with two permanent COM

Summary of the content on the page No. 6

Note: Typically, the minimum clearence to combustible The incandescent particle tray (shipped loose in the carton with the water heater) must be attached at the bottom of materials should not be less than 6“ for single wall flue the water heater front cover at the time of installation. Use pipe. Note that this clearance can be reduced if combustible the screws provided. See figure 3 materials are protected as per table VI of the National Fuel Gas Code or if Type B gas vent is used. MOUNTING INS

Summary of the content on the page No. 7

VENTING Vent pipe connection. WARNING: Do not reduce the vent pipe size. See Fig. 4 for high altitude installations The heater must be vented to the outside following all local ordinances and specifications for installing a gas appliance vent or chimney. The heater must be located as close as practicable to a vertically rising chimney or vent that has a listed vent cap at its termination point. The venting system must be designed and constructed so as to develop a positive flow adequate to r

Summary of the content on the page No. 8

MASONRY CHIMNEY: Masonry chimneys shall be built and installed in accordance with NFPS 211 or local codes. A minimum 5” diameter gas vent pipe (metal double wall Type B), or an approved clay flue liner or a listed chimney lining system must be used when venting into a naturally drafting, internal masonry chimney. 6 inch is required in elevations greater than 2000 feet, see Fig. 4. Local codes may require the use of both gas vent and an approved lining system when venting into a masonry chimney.

Summary of the content on the page No. 9

To check the draft: Close all doors and windows to the outside. Turn on all appliances that force air out of the building. These include all exhaust/ventilation fans, furnaces, clothes 5” X 6” ADAPTOR dryers, wood burning stoves, etc. USED ON HIGH ALTITUDE Open all doors between the AquaStar and these other appliances. With the control knob set fully clockwise and strong hot water flow rate, run the unit for at least 10 minutes. The 125B is equipped with a Flue Gas Sensor; it’s mounted on the r

Summary of the content on the page No. 10

GAS LINE SIZING GAS CONNECTIONS -It is strongly recommended that the Natural Gas pipe be Black Iron pipe the entire distance from the outside meter to the inlet of the Aquastar regulator. 1/2” Black NOTE: The Aquastar 125 B is supplied with a gas pressure Iron pipe up to 10 feet, 3/4” Black Iron pipe up to 40 feet regulator that must be installed on the heater before and 1” Black Iron pipe up to 150 feet distances. Flex line attaching the gas supply line. See fig. 5. Failure to install tubing is

Summary of the content on the page No. 11

GAS PIPING, CONNECTIONS and Gas Regulator Before connecting the gas supply, check the rating plate on the right side of the front cover to be sure that the heater is rated for the same gas to which it will be connected. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54. In Canada: The Installation should conform with CGA B149 INSTALLATION CODES and /or local installation codes. GAS LINE SIZING FO

Summary of the content on the page No. 12

WATER CONNECTIONS Install the heater centrally in the building if possible and make hot water piping runs as short as possible When facing the heater, the cold water inlet will be on the right and the hot water outlet on the left.. Although water piping throughout the building may be other than copper, copper or galvanized piping should be used when connecting to the heaters ½” male NPT flex connectors PIPE PRV TO (follow local codes if more stringent). Plastics or other PEX APPROPRIATE DISCHARG

Summary of the content on the page No. 13

LIGHTING INSTRUCTIONS (as seen on front cover of heater) GAS CONTROL SLIDE 1. STOP! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. TEMPERATURE ADJUSTMENT KNOB 3. Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above on this plate. If you don’t smell gas, go to next step. Fig. 9 - Water Flow Control Knob 4. The pilot burner is loca

Summary of the content on the page No. 14

Water Valve (Part # 8707002649): The water valve on this heater should be serviced periodically. Lubricate component #23 on page 19 with a small amount of silicon, faucet or lithium grease every two years to keep its o rings AIR SCREEN fresh and pushrod sliding smoothly. Every 3-5 years replace component #23 on page 19. The frequency will depend on the mineral content of the water and conditions of use or whenever signs of corrosion appear at the gas and water valve joint. Periodically check th

Summary of the content on the page No. 15

PILOT LIGHT WILL NOT LIGHT 3. Poor thermocouple connection at the electromagnet Note: Electromagnet is part #8707201012 located on the 1. No gas to the AquaStar right side of the gas valve behind the piezo push-button A. Gas cock on gas line may not be open. assembly. Check the tightness of the thermocouple B. Gas valve button has not been moved to single flame connection nut at the electromagnet: The Electro-magnet position ( ). Slide button to right to PILOT. connection is a large aluminu

Summary of the content on the page No. 16

5. Crossover in household plumbing WATER IS TOO HOT The AquaStar burner activates when there is sufficient water 1. Temperature Selection too high pressure drop in the AquaStar water valve assembly — i.e. Position the gas control slide to the single flame ( ) when a hot water faucet is opened. If there is a crossover in setting to reduce the burner output and/or turn the the plumbing, the necessary pressure drop in the AquaStar temperature adjustment knob counterclockwise to lower the will b

Summary of the content on the page No. 17

HOT WATER TEMPERATURE FLUCTUATES / UNIT DEACTIVATED 1. Unbalanced pressure in waterlines The added restriction caused by the Aquastar in the hot water system can result in uneven pressures between the cold and the hot. In such cases when mixing cold water at the tap, the lower hot water pressure may be overpowered by the higher cold water pressure in the building, which may cause the Aquastar burners to shut down (deactivate). Do not add any flow restrictor to the shower head. Position the gas c

Summary of the content on the page No. 18

18 6 720 607 030

Summary of the content on the page No. 19

Fig. 12 - Diagram of AquaStar 125 B 1 3 2 4 5 6 7 9 8 10 11 13 12 6720606800-07.1AL 1. Heat exchanger 8. Gas control slide 2. Pilot assembly 9. Piezo igniter 3. Burner manifold gas 10. Water valve pressure test nipple 11. Temperature adjustment 4. Main gas burner selector 5. Pilot gas tubing 12. Gas inlet gas pressure test 6. Gas valve nipple 7. Pressure tap screw 13. Flexible hot outlet location 6 720 607 030 19

Summary of the content on the page No. 20

Fig. 13 - INTERIOR COMPONENTS DIAGRAM AND PARTS LIST 20 6 720 607 030


Alternative user manuals
# User manual Category Download
1 Bosch Appliances 125HX LP User manual Water Heater 1
2 Bosch Appliances 125B NGS User manual Water Heater 0
3 Bosch Appliances AQUA STAR 2400E LP User manual Water Heater 7
4 Bosch Appliances AE115 User manual Water Heater 2
5 Bosch Appliances 600 User manual Water Heater 0
6 Bosch Appliances 125FX NG User manual Water Heater 0
7 Bosch Appliances AQ4 GWH 425 HN User manual Water Heater 0
8 Bosch Appliances AQUA STAR 250SX LP User manual Water Heater 0
9 Bosch Appliances BC2600RA User manual Water Heater 1
10 Bosch Appliances BC2600RA User manual Water Heater 0
11 Bosch Appliances GWH 1600 PS User manual Water Heater 1
12 Bosch Appliances 600 User manual Water Heater 0
13 Bosch Appliances AQUASTAR 125B NGL User manual Water Heater 3
14 Bosch Appliances GWH 2700 ES NG User manual Water Heater 0
15 Bosch Appliances GWH 2400 ES NG User manual Water Heater 1
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6