State Industries 186489-002 user manual

User manual for the device State Industries 186489-002

Device: State Industries 186489-002
Category: Water Heater
Manufacturer: State Industries
Size: 2.37 MB
Added : 2/26/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for State Industries 186489-002. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with State Industries 186489-002.

For your convenience

If looking through the State Industries 186489-002 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual State Industries 186489-002 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual State Industries 186489-002 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
State Industries 186489-002 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual State Industries 186489-002 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to State Industries 186489-002. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation Instructions and Use & Care Guide
RESIDENTIAL GAS WATER HEATERS
FVIR GAS WATER HEATER
(FLAMMABLE VAPOR IGNITION RESISTANT)
FOR SPACE HEATING AND POTABLE WATER HEATING ONLY.
NOT FOR USE IN MOBILE HOMES.
This water heater complies with ANSI Z21.10.1-current
edition regarding the accidental or unintended ignition of
fl ammable vapors, such as those emitted by gasoline.
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
WARNING: If the information in these

Summary of the content on the page No. 2

TABLE OF CONTENTS Water Heater Safety .......................................................................................................................................................................... 1 -2 Safe Installation, Use and Service ...................................................................................................................................................... 3 Safety Precautions .............................................................................

Summary of the content on the page No. 3

SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your water heater to warn you and others of a potential hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or s

Summary of the content on the page No. 4

Fire or Explosion Harzard Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Avoid all ignition sources if you smell Natural or LP gas. Do not expose water heater control to excessive gas pressure. Use only gas shown on rating plate. Maintain required clearances to combustibles. Keep ignition sources away from faucets after extended period of non-use. Read instruction manual before installing, using or servicing wa

Summary of the content on the page No. 5

TYPICAL INSTALLATION GET TO KNOW YOUR WATER HEATER - GAS MODELS A Vent Pipe J Inner Door S Gas Control Valve/Thermostat B Draft hood K Outer door T Drain Valve C Anode (Not Shown) L Union U Pilot and Main Burner D Hot Water Outlet M Inlet Water Shut-off Valve V Flue E Insulation N Cold Water Inlet W Drain Pan F Gas Supply Piping O Inlet Dip Tube X Piezo Igniter* G Manual Gas Shut-off Valve P Temperature & Pressure Relief Valve Y Base Filter H Ground Joint Union Q Rating Plate I

Summary of the content on the page No. 6

INSTALLING YOUR GAS WATER HEATER Unpacking the Water Heater Important Information About This Water Heater This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable WARNING vapor ignition incident. New technology used in meeting these standards makes this product more sensitive to Excessive Weight Hazard installation errors or improper installation environments. Please review the Installation Checkli

Summary of the content on the page No. 7

If flammable liquids or vapors have spilled or leaked in Location Requirements the area of the water heater, leave the area immediately and call the fire department from a neighbor’s home. Do not attempt to clean the spill until all ignition sources have been extinguished. WARNING Carbon Monoxide Poisoning Hazard Do not install in a mobile home. WARNING Doing so can result in carbon monoxide poisoning and death. Fire or Explosion Hazard • Re

Summary of the content on the page No. 8

EXHAUST FAN REVERSE FLOW OF GASES IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower FIGURE 1. floors of the structure. Due to the normal corrosive action of water, the tank will eventually leak after an extended period Clearances and Accessibility of time. Also any external plumbing leak, including those from improper installat

Summary of the content on the page No. 9

GAS SUPPLY WARNING MANUAL GAS SHUT-OFF VALVE GROUND DISCHARGE PIPE JOINT (DO NOT PLUG OR CAP) UNION CHECK WITH LOCAL UTILITY FOR MINIMUM HEIGHT Explosion Hazard • Use a new CSA approved gas supply line. 3” MINIMUM • Install a shut-off valve. 6” MAXIMUM DRIP LEG AIR GAP • Do not connect a natural gas water heater to an L.P. gas SUITABLE DRAIN supply. FIGURE 3. • Do not connect an L.P. gas water heater to a natural gas Gas Pressure sup

Summary of the content on the page No. 10

LP Gas Only Liquefied petroleum gas is over 50% heavier than air and in the occurrence of a leak in the system, the gas will settle at floor level. Basements, crawl spaces, closets WARNING and areas below ground level will serve as pockets for the accumulation of gas. Before lighting an L.P. gas water heater, smell all around the appliance at floor level. If you smell gas, follow the instructions as given in the warning o

Summary of the content on the page No. 11

COMBUSTION AIR & VENTILATION TABLE 3 Minimum WARNING Square Typical Room BTUH Input Feet with Carbon Monoxide Warning with 8’ Ceiling 8’ Ceiling Water heater must be vented to outdoors. 30,000 188 9 x 21 Vent must be installed by a qualified technician using the installation instructions. 45,000 281 14 x 20 Examples of a qualified technican include: gas 60,000 375 15 x 25 technicians, authorized gas company personel, and 75,000 469 15 x 31 authorized service persons. 90,000 563 20 x 28 Failu

Summary of the content on the page No. 12

fresh air can be taken from the outdoors or from crawl or 12” MAXIMUM attic spaces that freely communicate with the outdoors. Attic or crawl spaces cannot be closed and must be properly ventilated to the outside. Ductwork must be of the same cross-sectional area as CLOSET the free area of the opening to which they connect. The OR PERMANENT minimum dimension of rectangular air ducts cannot be less OTHER OPENINGS TO CONFINED than three inches. THE OUTSIDE OR SPACE ADDITIONAL The size o

Summary of the content on the page No. 13

GABLE VENT TO OUTDOORS ALTERNATIVE INSTALL ABOVE OPENING INSULATION LOCATION 1 SQ. INCH CONFINED CONFINED OUTLET PER 3000 BTUH SPACE AIR TO SPACE ATTIC 1 SQ. INCH PER 4000 BTUH INLET AIR FROM ALTERNATE THE CRAWL SPACE AIR INLET ALL AIR FROM OUTDOORS - USING A SINGLE PERMANENT OPENING 1 SQ. INCH PER OPEN FIGURE 8B. 4000 BTUH FOUNDATION VENT Vent Pipe System ALL AIR FROM OUTDOORS: INLET AIR FROM VENTILATED CRAWL SPACE/OUTLET AIR TO VENTILAT

Summary of the content on the page No. 14

Align the legs of the draft hood with the slots provided. • The connector must be installed above the extreme Insert the legs and secure the draft hood to the water bottom of the chimney to prevent potentially blocking heater’s top with the four screws provided as shown in the flue gases. Figure 9. Do not alter the draft hood in any way. If you are • The connector must be firmly attached and sealed to replacing an existing water heater, be sure to use the draft prevent it from falling out.

Summary of the content on the page No. 15

LISTED VENT CAP WATER SYSTEM PIPING 2 FT. MINIMUM ABOVE ANY OBJECT Piping Installation WITHIN 10 FT. HORIZONTALLY 3 FT. MINIMUM SUPPORT Piping, fittings, and valves should be installed according STRAP to the installation drawing (Figure 13). If the indoor *MAINTAIN installation area is subject to freezing temperatures, the TYPE B DOUBLE CLEARANCE WALL VENT PIPE water piping must be protected by insulation. The water supply pressure should not

Summary of the content on the page No. 16

Please note the following: IN A CLOSED SYSTEM USE A • The system should be installed only with piping that is THERMAL EXPANSION TANK suitable for potable (drinkable) water such as copper, COLD WATER SUPPLY TO FIXTURES CPVC, or polybutylene. This water heater must not be PRESSURE REDUCING VALVE WITH BYPASS installed using iron piping or PVC water piping. HOT WATER COLD WATER • Use only pumps, valves, or fittings that are compatible INLET OUTLET with potable water. COLD WATER INLET VALVE (S

Summary of the content on the page No. 17

valve or have any reducing coupling installed in the Temperature and Pressure Relief Valve discharge line. • Must not be capped, blocked, plugged or contain any valve between the relief valve and the end of the dis- charge line. Explosion Harzard • Must terminate a maximum of six inches above a floor drain or external to the building. • Temperature-pressure relief valve must comply with ANSI • Must be capable of withstanding 250°F (121°C) without Z21.22-CSA 4.4 and ASM

Summary of the content on the page No. 18

• Be sure to follow the manual(s) shipped with the air Also see Water System Piping for additional instructions handler system. on the safe and correct installation and operation of this water heater. • This water heater is not to be used as a replacement for an existing boiler installation. MUST BE VERTICAL TO DOMSETIC REMOVE AIR BUBBLES EXPANSION TANK HOT WATER • Do not use with piping that has been treated with OUT COLD WATER INLET VACUUM chromates, boiler seal or other chemicals and do

Summary of the content on the page No. 19

IMPORTANT INFORMATION ABOUT THIS WATER HEATER This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes. Questions? Contact Residential Technical Assistance by referencing the phone number on the front of the Installat

Summary of the content on the page No. 20

ON ON ON OPERATING YOUR WATER HEATER Lighting Instructions Read and understand these directions thoroughly before WARNING attempting to light or re-light the pilot. Make sure the view Explosion Hazard port is not missing or damaged. (See Figure 23) Make sure the tank is completely filled with water before lighting Replace view port if glass is missing the pilot. Check the rating plate near the gas control valve/ or damaged. thermostat for th


Alternative user manuals
# User manual Category Download
1 State Industries 184735-000 User manual Water Heater 0
2 State Industries 186589-001 User manual Water Heater 0
3 State Industries 184748-001 User manual Water Heater 0
4 State Industries 196114-000 User manual Water Heater 0
5 State Industries 195115-000 User manual Water Heater 0
6 State Industries 185244-004 User manual Water Heater 0
7 State Industries 201 Series User manual Water Heater 0
8 State Industries 317913-000 User manual Water Heater 0
9 State Industries 197425-004 User manual Water Heater 0
10 State Industries 198067-000 User manual Water Heater 0
11 State Industries 305 Interior User manual Water Heater 0
12 State Industries 315466-000 User manual Water Heater 0
13 State Industries 305 Exterior User manual Water Heater 0
14 State Industries 50 DXRS User manual Water Heater 0
15 State Industries 52 User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6