Rheem SolPak Active Series RS120-64BP user manual

User manual for the device Rheem SolPak Active Series RS120-64BP

Device: Rheem SolPak Active Series RS120-64BP
Category: Water Heater
Manufacturer: Rheem
Size: 5.27 MB
Added : 2/4/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Rheem SolPak Active Series RS120-64BP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Rheem SolPak Active Series RS120-64BP.

For your convenience

If looking through the Rheem SolPak Active Series RS120-64BP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Rheem SolPak Active Series RS120-64BP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Rheem SolPak Active Series RS120-64BP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Rheem SolPak Active Series RS120-64BP User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Rheem SolPak Active Series RS120-64BP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Rheem SolPak Active Series RS120-64BP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Use & Care Manual
With Installation Instructions for the Installer
Pumped Solar Water
Heating Systems
The purpose of this manual is twofold:
one, to provide the installer with the basic
directions and recommendations for the proper
installation and adjustment of the water heater;
and two, for the owner–operator, to explain
the features, operation, safety precautions,
maintenance and troubleshooting of the water
heater. This manual also includes a parts list.
It is very important that all

Summary of the content on the page No. 2

Safety Information FOR YOUR RECORDS Introduction ............ 3, 4 Write the model and serial numbers here: Safety Precautions ....... 5, 6 Model Number of Solar System Tank: ____________________________________ Preface Serial Number of Solar System Tank: _____________________________________ Model Number of Collector Panel #1: ____________________________________ 1) Introduction . . . . . . . . . . . . 1 Serial Number of Collector Panel #1: _____________________________________ Model Number of

Summary of the content on the page No. 3

Introduction Thank you for purchasing a solar water heating The solar energy system described by this manual, system. It is one of the most effective and trouble- when properly installed and maintained, meets the free systems available today. In addition to reducing minimum standards established by the Florida Solar your water-heating bills, it will help preserve precious Energy Center, in accordance with Section 377.705, natural resources by using free energy from the sun. Florida Statute

Summary of the content on the page No. 4

Introduction continued... Keep the use of the Backup Heater to a Minimum You can save the most money on your water-heating bills by using the backup heater on your system as little as possible. If the sun shines brightly between I0 am and 3 pm, enough heat will normally be generated to keep the water hot throughout the rest of the day and night. However, on days when the sky is cloudy or when large quantities of hot water are being used, we suggest that the backup heater be left “ON” over

Summary of the content on the page No. 5

T E S E R IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. ! DANGER! WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of water heater’s thermostat. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. Time/Temperature Relationship in Scalds Temperature Time To Produce a Serious Burn 120°F

Summary of the content on the page No. 6

IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. ! WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and cost. Pay particular attention to the Safety Instructions. Failure to follow these w

Summary of the content on the page No. 7

PREFACE Rheem solar system. This system is required to be installed by properly licensed solar or plumbing Let us first offer two words of grateful appreciation. contractors in accordance with SRCC Standard OG- Thank You! We sincerely appreciate your business. 300 and all applicable national, state and local codes, Rheem also wishes to say thank you for "going ordinances and regulations governing solar water solar". Solar water heating systems help to reduce heating installations, as well as

Summary of the content on the page No. 8

COLLECTOR ORIENTATION fig. 1 COLLECTOR ORIENTATION ferred fig. to 1the HTF circulating through the solar approximately twelve degrees hotter than the collector. The system pump efficiently circulates temperature in the bottom of your solar storage this heated fluid through the collector piping and tank, the controller will turn the circulating pump the controller will turn the circulating pump on. When Propylene glycol can degrade over time. The process ferred to the HTF circulating through th

Summary of the content on the page No. 9

TABLE 1 LATITUDE 25°N 30°N 35°N 40°N 45°N 50°N COLL. TILT 35° 40° 45° 50° 55° 60° TABLE 1 A B A B A B A B A B AB FLAT 29 96 33 113 37 145 41 145 44 145 48 145 LATITUDE 25°N 30°N 35°N 40°N 45°N 50°N 5° 1/12 25 83 29 93 33 113 37 132 41 133 44 141 COLL. TILT 35° 40° 45° 50° 55° 60° 9° 2/12 22 74 26 82 30 77 34 110 38 115 41 118 A B A B A B A B A B AB 14° 3/12 17 66 22 72 26 82 30 92 34 95 38 98 FLAT 29 96 33 113 37 145 41 145 44 145 48 145 18° 4/12 14 61 18 66 22 74 26 82 30 85 34 87 5° 1/12 25 83

Summary of the content on the page No. 10

fig.4 fig.5 REVERSE PITCH MOUNTING COMPOSITION SHINGLE MOUNTING in the Northern Hemisphere is optimized when the The collector should be unshaded by any permanent collector is mounted facing True South. Performance, obstacle between 9:00 a.m. and 3:00 p.m. on any day 4.2 Collector Tilt be unshaded for the majority of the day all however, suffers very little when the collector is of the year. oriented no more than 45° East or West of True South. year round. Adjacent buildings and trees 10 Opt

Summary of the content on the page No. 11

fig.5 COMPOSITION SHINGLE MOUNTING 4.2 Collector Tilt horizontal orientation on the roof (See Figure 1). Although the collector is protected from freeze Optimal annual efficiency is achieved by tilting the conditions by the glycol HTF and does not normally solar collector at an angle that equals your latitude need to be drained, it is still important to slope the plus an additional 10°. This tilt angle favors the lower collectors just slightly to allow for complete drainage winter sun when

Summary of the content on the page No. 12

Installing the water heater. fig.6 SHINGLE ROOF MOUNTING attic workspace. the collectors and for proper ventilation of the roofing material. There should be at least 3" of clearance The solar collector should be mounted on the roof in between the roof surface and the bottom of the solar accordance with these general principles: collectors. 4.3.1 The most important structural consideration is 4.3.3 In selecting mounting hardware and fasteners to securely anchor the solar collector and the Rhe

Summary of the content on the page No. 13

fig.7 TILE ROOF MOUNTING that all roof penetrations required to plumb and mount must be well insulated with a high quality flexible the solar collector are properly flashed and sealed in closed cell insulation to minimize heat loss. The wall accordance with standard roofing practices. thickness of the pipe insulation should not be less than 3/4". A 1" wall thickness is required in all areas prone to annual hard freeze conditions. When it comes to pipe 4.3.5 If the region is subject to hurri

Summary of the content on the page No. 14

Installing the water heater. fig.8 TILE ROOF MOUNTING Any above ground exterior pipe insulation is subject Piping in new solar installations can be covered with to UV degradation and must be wrapped with foil tape dirt, grease, solder flux or other impurities that over or painted with two coats of high quality water-based time affect the quality of the glycol HTF. A thorough acrylic resin coating as supplied by the insulation cleaning is required before charging the system with manufacturer.

Summary of the content on the page No. 15

fig.9 FLUSH MOUNTING 4.6 Collector Sensor Placement Figure 13 for collector sensor installation detail. The collector sensor must be located on the hot 4.7 Low Voltage Wiring water return line as close to the collector as possible. Sensors are typically accurate to +/- 1/2°F if properly The low voltage wiring used to connect the sensors installed and weatherized. To maximize sensor to the controller should be a minimum18 AWG. accuracy, attach the flanged portion of the sensor to The wiring sh

Summary of the content on the page No. 16

Installing the water heater. fig.10 FLUSH MOUNTING easy to reach. Provide for clear access to the storage heater. If not detected in a timely manner even a small tank, pump, expansion tank, mixing valve, time clock drip or leak may cause serious damage to the tank’s (optional, not provided) and other key components. If electrical components or, in extreme cases, may cause a component in the potable water side of the system the tank to leak from the outside in. may require future service or ma

Summary of the content on the page No. 17

fig.11 TILT MOUNT In a single tank system install a third thermometer on the solar storage tank or after the mixing valve on (No. 3) directly after the mixing valve above the solar the back-up water heater. storage tank. In a two tank system you may install the third thermometer either directly above the hot outlet The circulation pump shall be the Grundfos model 17

Summary of the content on the page No. 18

Installing the water heater. fig.12 STAND OFF TILT MOUNT UPS15-5BFC/LC, 115 volt. The pump shall be component in all OG-300 certified systems and should prewired with a 6’ line cord so that it can be plugged be plumbed in line with brass union connections for directly into the 115 volt receptacle on the side of ease of future repair or replacment (No. 32). The the differential control. Two way ball valves must specified mixing valve shall be the Heatguard model be installed on either side of

Summary of the content on the page No. 19

collector in the summer months or under stagna- tion conditions can melt this type of material. Any above ground exterior pipe insulation is sub- ject to UV degradation and must be wrapped with foil tape or painted with two coats of high quality water-based acrylic resin coating as sup- plied by the insulation manufacturer. Rubatex UV Protective Coating or equal is the required coating material. 4.5 Collector Plumbing SunEarth requires the use of all copper and brass fittings in the collect

Summary of the content on the page No. 20

collector in the summer months or under stagna- tion conditions can melt this type of material. Any above ground exterior pipe insulation is sub- ject to UV degradation and must be wrapped with foil tape or painted with two coats of high quality water-based acrylic resin coating as sup- plied by the insulation manufacturer. Rubatex UV Protective Coating or equal is the required coating material. 4.5 Collector Plumbing SunEarth requires the use of all copper and brass fittings in the collect


Alternative user manuals
# User manual Category Download
1 Rheem 000 BTU User manual Water Heater 107
2 Rheem 100 User manual Water Heater 105
3 Rheem 000 BTU max User manual Water Heater 18
4 Rheem 120 User manual Water Heater 83
5 Rheem 000 - 180 User manual Water Heater 39
6 Rheem 11 User manual Water Heater 6
7 Rheem 175 User manual Water Heater 1
8 Rheem 110 User manual Water Heater 7
9 Rheem 130 User manual Water Heater 6
10 Rheem 19 User manual Water Heater 9
11 Rheem 208 User manual Water Heater 0
12 Rheem 136-1826 User manual Water Heater 8
13 Rheem 115 User manual Water Heater 2
14 Rheem 199 User manual Water Heater 6
15 Rheem 240 User manual Water Heater 4
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6