Raypak 405 user manual

User manual for the device Raypak 405

Device: Raypak 405
Category: Water Heater
Manufacturer: Raypak
Size: 0.55 MB
Added : 5/25/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Raypak 405. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Raypak 405.

For your convenience

If looking through the Raypak 405 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Raypak 405 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Raypak 405 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Raypak 405 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Raypak 405 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Raypak 405. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CATALOG NO. 6000.57D
Effective: 10-26-06
Replaces: 03-15-03
OPERATING AND
INSTALLATION
INSTRUCTIONS
Models
185, 265, 335, 405
Swimming Pool and Spa Heaters
181/182, 260/261, 330/331, 400/401
Water Heaters and Boilers
D-2 POWER VENT
(FOR ELECTRONIC IGNITION MODELS ONLY)
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids or other combustible
materials in the vicinity of this or any other appliance. To do so may result in an explosion
or fire.
WARNING:

Summary of the content on the page No. 2

POWER VENT ASSEMBLY INSTALLATION, START-UP AND OPERATION 1. RECEIVING EQUIPMENT On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the complete assembly from the carton if it is damaged report the damage to the carrier immediately. Be sure that you receive the number of packages indicated on the Bill of Lading. Claims for

Summary of the content on the page No. 3

3. INSTALLATION REQUIREMENTS The equipment must be installed in accordance with local codes, or in the absence of local codes with the latest edition of the National Fuel Gas Code, ANSI Z223.1, the National Electrical Code, ANSI/NFPA 70. The equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction shall be consulted before insta

Summary of the content on the page No. 4

MOUNTING POWER VENT ASSEMBLY-(continued 11. Mount the PowerVent assembly bottom on the 6” vent. Twist the assembly downward. Snap the mounting brackets into their appropriate slot to hold the Power Vent in position. Note: While twisting you may notice some roughness, this is due to a tight seal between the 6” vent and the Power Vent flue box. 12.Re-mount the access panel. 13.Re-mount the front door along with the knurled screw on the heater. Fig #9356 ** NOTE: The 90° elbow may be used as a te

Summary of the content on the page No. 5

VENTING The vent pipe must be the same size or larger than what is indicated. The D-2 Power Vent are capable of 360-degree discharge rotation and operate with a positive vent static pressure and with a vent gas temperature less than 400°F. The total length of horizontal run shall not exceed an equivalent of 40 feet including termination cap. For all cases, each 90-degree elbow reduces the maximum horizontal vent run by 10 feet and each 45-degree elbow in the vent run reduces the maximum vent

Summary of the content on the page No. 6

The Raypak Power Vent operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent and as such it is listed as a CATEGORY III appliance. Exception: When a Power Vent is connected to a vertical vent of sufficient height to generate a negative draft in the system. Consult sizing guide or factory. The D-2 Power Vent assembly is suitable for through the wall venting, and for connection to smaller size vent pipes and breeching

Summary of the content on the page No. 7

185-405 POOL HEATER (ATMOSPHERIC) 7

Summary of the content on the page No. 8

185-405 POOL HEATER (Low NOx) 8

Summary of the content on the page No. 9

182-260 WH1 (ATMOSPHERIC) 9

Summary of the content on the page No. 10

181-261 WH1 (Low NOx) 10

Summary of the content on the page No. 11

Dimensional Data Model A B C D 181 18.13 12.38 7.88 4.25 182 18.13 12.38 7.88 4.25 185 18.13 12.38 7.88 4.25 260 18.13 12.38 7.88 4.25 261 18.13 12.38 7.88 4.25 265 18.13 12.38 7.88 4.25 330 17.50 15.75 7.63 6.00 331 17.50 15.75 7.63 6.00 335 17.50 15.75 7.63 6.00 400 17.50 15.75 7.63 6.00 401 17.50 15.75 7.63 6.00 405 17.50 15.75 7.63 6.00 Fig #9387 SEQUENCE OF OPERATION On call for heat, the D-2 Power Vent fan (and appliance pump) start. When the flow switch circuits close, the ignition syst

Summary of the content on the page No. 12

START UP PROCEDURES EMERGENCY SHUTDOWN The water system, the gas system and the SHUT OFF ALL POWER AND GAS, CALL electrical system for the heater should be GAS UTILITY. completed and checked as per the heater installation manual and associated documents. DRAFT PROVING SWITCH 1. Turn on power to the heater with the manual The draft proving switch insures that the main gas valve and pilot gas valve off. The blower is operating. The switch is in the limit electric power supply requirements are:

Summary of the content on the page No. 13

ILLUSTRATED PARTS LIST 4 9 10 5 11 1 6 3 2 15 7 12 13 14 8 13

Summary of the content on the page No. 14

www.raypak.com Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725 Raypak Canada LTD, 2805 Slough Street, Mississauga, Ontario, Canada L4T 1G2 (905) 677-7999 FAX (905) 677-8036 Raypak Australia Pty. Ltd, 7 Geddes St., Mulgrave, Victoria, Australia 3170 (6139) 560 4944 FAX (6139) 560 4974 Litho in U.S.A.


Alternative user manuals
# User manual Category Download
1 Raypak 2100 - 4001 User manual Water Heater 17
2 Raypak 260-401 User manual Water Heater 3
3 Raypak 2600401 User manual Water Heater 0
4 Raypak 195A User manual Water Heater 1
5 Raypak 185 User manual Water Heater 3
6 Raypak 335 User manual Water Heater 1
7 Raypak 302B-902B User manual Water Heater 2
8 Raypak 135A User manual Water Heater 2
9 Raypak B0147 User manual Water Heater 0
10 Raypak B-195 User manual Water Heater 0
11 Raypak DEL TA LIMITED 399B User manual Water Heater 1
12 Raypak B0109 User manual Water Heater 0
13 Raypak 265 User manual Water Heater 0
14 Raypak DELTA LIMITED 2339B User manual Water Heater 0
15 Raypak Dual-Fuel Hot Water Boilers 992BD-2342BD User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6