Kenmore 153.335963 user manual

User manual for the device Kenmore 153.335963

Device: Kenmore 153.335963
Category: Water Heater
Manufacturer: Kenmore
Size: 2.16 MB
Added : 7/19/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Kenmore 153.335963. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Kenmore 153.335963.

For your convenience

If looking through the Kenmore 153.335963 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Kenmore 153.335963 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Kenmore 153.335963 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Kenmore 153.335963 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Kenmore 153.335963 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Kenmore 153.335963. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owners
Manual
FOR POTABLE WATER
HEATING ONLY
NOT SUITABLE FOR
SPACEHEATING
NOT FOR USE IN
MOBILE HOMES
POWER MISER TM 9
Model No.
153.335816 40 Gal.
POWER VENT
153.335846 40 Gal. High Altitude L.R
153.335863 40 Gal. L.R
GAS WATER HEATER
153.335916 50 Gal.
• Safety Instructions • Care and Maintenance
153.335943 50 Gal. High Altitude L.R
153.335963 50 Gal. L.!_
• Installation • Troubleshooting
• Operation • Parts List
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED BY THIS
WATER HEATER
WARNING

Summary of the content on the page No. 2

Safety Precautions _,WARNING J _,WARNING 1 Improper installation, adjustment, alteration, service orJ At the time of manufacture this water heater was provid- maintenance can cause death, serious bodily injury, orJ ed with a combination temperature-pressures relief valve property damage. Refer to this manual for assistanceorJ certified by a nationally recognized testing laboratory consult your local Sears Service Center for furtherJ that maintains periodic inspectionof production of listed equip

Summary of the content on the page No. 3

Safety Precautions AWARNING _,WARNING A gas water heater cannot operate properly without the This water heater must not be installed directly on car- correct amount of air for combustion. Do not install in a peting. Carpeting must be protected by a metal or wood confined area such a closet, unless you provide air as panel beneath the appliance extending beyond the full shown in the "Locating The New Water Heater" section. width and depth of the appliance by at least 3 inches Never obstruct the f

Summary of the content on the page No. 4

Safety Precautions AWARNING AWARNING J The water heater wi_talled must be prop- I Vent termination must not be within 4 feet of any items J erly vented to a chimney which terminates outdoors. I such as gas meters, gas valves or other gas regulating Never operate the water heater unlessit is vented to the I equipment. outdoors and has adequate air supply to avoid risks of I improper operation, explosionor asphyxiation. J A CAUTION WATER HEATERS EVENTUALLY LEAK: Installation of AWARNING the water

Summary of the content on the page No. 5

Table of Contents _¢...._,a,,.ty Precautions ............................................................................................................................................ 2-4 Table of Contents ................................................................................................................................................ 5 Customer l_esponsibilities ......................................................................................................................

Summary of the content on the page No. 6

Customer Responsibilities _""inanK You for purchasing a Sears water heater. Properly This manual contains instructions for the installation, opera- installed and maintained, it should give you years of trouble free ser- tion, and maintenance of the gas-fired water heater. It also vice. If you should decidethat you wantthe new waterheater profes- contains warnings through out the manual that you must read sionally installed by Sears call the local Seats ServiceCenter or any and be aware of. All w

Summary of the content on the page No. 7

Materials and Basic Tools Needed Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materi- als, depending on your type of installation. WATER HEATER STAND 24"x24"xlS" FOR USE WITH WATER HEATERS Gas INSTALLED IN RESIDENTIAL Water Heater GARAGES HAVING A DIAMETER 24" Installation OR LESS AND A RATED CAPACITY 75 K_t GALLONS OR LESS EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLON AND 5 GAL

Summary of the content on the page No. 8

Installation Instructions Removing the Old Water Heater "OFF" the the heater. Q Turn gas supply to water Q Disconnect the vent pipe from the draft hood where they connect to the water heater. In most installations the vent pipe can be lifted off after any screw or other _WARNING attached devices are removed. Dispose of the draft If the main gas line shutoff serving all gas appliances is hood. The new water heater has the draft hood which used, also shut "off" the gas at each appliance. Leave all

Summary of the content on the page No. 9

Installation Instructions Locating the New Water Heater 5. The location selection must provide adequate clearances for servicing and proper operation of the water heater. You should carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most AWARNING economical use of the appliance. This water heater is not for INSTALLATIONSIN AREASWHERE FLAMMABLELIQUIDS use in mobile homes

Summary of the content on the page No. 10

Installation Instructions (cont'd) AWARNING 9"min. from A gas water heater cannot operate properly without the cor- any overhang rect amount of air for combustion. Do not install in a con- -_. of Flue fined area such a closet, unless you provide air as shown in the "Locating The New Water Heater" section. Never 12" min. obstruct the flow of ventilation air If you have any doubts or r questions at all, call your gas company. Failure to provide the proper amount of combustion air can result in a f

Summary of the content on the page No. 11

Installation Instructions (cont'd) Venting Through Roof- Clearances • 0" clearance for 3" (or optional 2") PVC, ABS, or CPVC Schedule 40 piping from combustible surfaces. • The Power Vent outlet terminal shall terminate at least 18" above the roof surface. Figure 5. • The location selection must provide clearances for servicing and proper operationof thewaterheater. Figure4, • The venting system must be installed in a manner which allows inspection of the installation of the venting pipes and jo

Summary of the content on the page No. 12

Installation Instructions (cont'd) Combustion Air and Ventilation for Appliances Located in Unconfined Spaces Unconfined Space is a space whose volume is not less than 50 cubic 1. When directly communicating with the outdoors, each opening feet per 1,000 Btu per hour of the aggregate input rating of all appli- shall have a minimum free area of 1 square inch per 4,000 BTU ances installed in that space. Rooms communicating directly with the per hour of total input rating of all equipment in the en

Summary of the content on the page No. 13

Installation Instructions (cont'd) Water Piping 2. Look at the top cover of the water heater. The cold water AWARNING inlet is marked cold. Put two or three turns of teflon tape HOTTERWATERCAN SCALD:Water heatersare intendedto around the threaded end of the threaded-to-sweat coupling )reduce hot water.Water heatedto a temperaturewhichwill and around both ends of the _" threaded nipple. Using flexi- satisfy clotheswashing, dishwashing, andother sanitizing needs ble connectors, connect the cold wa

Summary of the content on the page No. 14

Installation Instructions (cont'd) Temperature-Pressure Relief Valve _,WARNING _-- AWARNING The temperature.pressure relief valve must be manually At the time of manufacturethiswater heater wasprovided operated at least once a year.Caution should be taken to with a combination temperature-pressures relief valvecertified ensurethat (I) no one is in front of or aroundthe outlet of by a nationallyrecognizedtesting laboratory that maintains the temperature-pressurerelief valvedischargeline,and (2) p

Summary of the content on the page No. 15

Installation Instructions (cont'd) Filling the Water Heater You must provide all wiring of the proper size outside of the water heater. You must obey local codes and electric company • , CAUTION requirements when you install this wiring. Never usethiswater heater unlessit iscompletelyfilledwith water.To preventdamageto the tank, the tank must be filled if you are not tb.miliar with electric codes and practices, or if you with water. Water must flow from the hot water faucet have any doubt, even

Summary of the content on the page No. 16

Installation Instructions (cont'd) USE WITHOUT POWER CORD (cont'd) water heater's junction box. Connect ground wire to this 3. A standard _" conduit opening has been made in the water location. For complete grounding details and all allowable heater junction box for the conduit connection. exceptions, refer to local codes or in the absence of local 4. Use wire nuts and connect the power supply wiring to the codes, with the latest edition of the National Electrical Code, wires inside the water he

Summary of the content on the page No. 17

Installation Instructions (cont'd) Venting (cont'd) ALL 40 GALLON AND 50 GALLON 40,000 BTU/HR AWARNING ] MODELS -- OPTIONAL 2" VENT PIPING surevent pipe is properlyconnectedto preventescapeof| 2" PVC Schedule 40 vent piping: gerousfluegases whichcouldcausedeadlyasphyxiation. ] 1. A wire screen to fit a 2" PVC Schedule 40-45 ° vent cap is AWARNING supplied with the water heater. Chemical vapor corrosionof the flue and vent systemmay occurif air for combustioncontainscertainchemicalvapors. 2, A 2"

Summary of the content on the page No. 18

Installation Instructions (cont'd) VENTING SYSTEM EXAMPLE INSTALLATIONS 2. Horizontal runs require a minimum V,,"rise per foot. FOR ALL MODELS The vent piping cannot under any circumstances be run down- 35' MAX. hill. 16" MIN, 13" MIN. MIN. RISE ¼" I1" MIN. PERFOOT 3. The total vertical and horizontal run cannot exceed 35' for 3" vent piping (20' maximum if 2" vent piping is _:se_ on 40,000 BTU/Hr. models) with a maximum of three 90 ° elbows. The vent piping can be inst_led as follows: 1. No mor

Summary of the content on the page No. 19

Installation Instructions (cont'd) Venting (cont'd) CEMENTING PVC, ABS OR CPVC PIPE AND FITTINGS CUTTING OPENING THROUGH AN OUTSIDE WALL AND COLLAR INSTALLATION Read and observe all safety information printed on primer, cleaner, and cement containers. After reading the manual and you have determined the location of the opening in the wall, (using the drawing below), cut a 3B" hole through an exterior wall. • , DANGER NOTE: When determining location of the opening in the Primer, cleaner, and ceme

Summary of the content on the page No. 20

Installation Instructions (cont'd) Venting (cont'd) VENTING THROUGH A ROOF CONNECTING PVC PIPE VENT TO BLOWER ALL MODELS I. The manufacturer has supplied a 3" PVC Schedule 40 street elbow for connection to the water heater when turning immeo I. The water heater requires its own (separate) venting system. diately horizontally off the blower. Place the elbow in the 2. It cannot be connected to existing vent piping or chimney. required direction on the blower and using 3 sheet metal screws, attach


Alternative user manuals
# User manual Category Download
1 Kenmore 153 327566 50 GAE User manual Water Heater 1
2 Kenmore 153.32118 User manual Water Heater 0
3 Kenmore 153.326462 40 GA!. User manual Water Heater 1
4 Kenmore 153.326363 30 GAL. User manual Water Heater 0
5 Kenmore 153.326362 30 GAL. User manual Water Heater 0
6 Kenmore 153.326463 40 GAL. User manual Water Heater 1
7 Kenmore 153.326562 55 GAL. User manual Water Heater 0
8 Kenmore 153.31702 User manual Water Heater 1
9 Kenmore 153.326662 50 GAL User manual Water Heater 0
10 Kenmore 153.326563 55 GAL. User manual Water Heater 2
11 Kenmore 153.32116 User manual Water Heater 0
12 Kenmore 153.326762 40 GAL. User manual Water Heater 0
13 Kenmore 153.326663 50 GAL. User manual Water Heater 1
14 Kenmore 153.326763 40 GAL User manual Water Heater 0
15 Kenmore 153.327565 50 GAL User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6