Honeywell Gas user manual

User manual for the device Honeywell Gas

Device: Honeywell Gas
Category: Water Heater
Manufacturer: Honeywell
Size: 1.76 MB
Added : 8/12/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell Gas. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell Gas.

For your convenience

If looking through the Honeywell Gas user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell Gas on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell Gas to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell Gas User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell Gas but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell Gas. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DIRECT VENT GAS WATER HEATER

A Spanish language version of these instructions is available by contacting the

company listed on the rating plate.

La versión espãnola de estas instrucciones se puede obtener al escribirle a la

fábrica cuyo nombre aparece en la placa de especificaciones.
INSTALLATION & OPERATING INSTRUCTION MANUAL

WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or de

Summary of the content on the page No. 2

CONGRATULATIONS! You have just purchased one of the finest water heaters on the market today! This installation, operation and instruction manual will explain in detail the installation and maintenance of your new Direct Vent Gas Water Heater. We strongly recommend that you contact a plumbing professional for the installation of this water heater. We require that you carefully read this manual, as well as the enclosed warranty, and refer to it when questions arise. If you have a

Summary of the content on the page No. 3

TABLE OF CONTENTS page GENERAL INFORMATION ......................................................................... 4 INSTALLATION........................................................................................ 5 Locating The Water Heater .................................................................... 5 Minimum Clearances .............................................................................. 8 Optional Direct Vent-Air Intake Terminal Guard........................

Summary of the content on the page No. 4

GENERAL INFORMATION This gas-fired water heater’s design is certified by CSA International under the American National Standard Z21.10.1 - (latest edition) and CSA 4.1-M - (latest edition). This water heater must be installed in accordance with local codes or, in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1- (Latest Edition) and/or in Canada CAN/CGA B149 Installation Codes (Latest Editions). The warranty for this water heater is in effect only when the water h

Summary of the content on the page No. 5

General Information continued- IMPORTANT Before proceeding, please inspect the water heater and its components for possible damage. DO NOT install any damaged components. If damage is evident then please contact the supplier where the water heater was purchased or the manufacturer listed on the rating plate for replacement parts. Make sure that you check the rating plate and combination gas control on the water heater to be certain that the type of gas being supplied corresponds wit

Summary of the content on the page No. 6

Installation (Locating The Water Heater) continued- The location of this water heater is of the utmost importance. Before installing this water heater read the Installation section of these instructions. After reading these Installation and Operating Instructions, select a location for the water heater where the floor is level and is easily accessible to gas and water supply lines. DO NOT locate the water heater where water lines could be subjected to freezing temperatures. Make sure th

Summary of the content on the page No. 7

Installation (Locating The Water Heater) continued- WARNING Liquefied petroleum gases/propane gas are heavier than air and will remain at floor level if there is a leak. Basements, crawl spaces, closets and areas below ground level will serve as pockets for accumulation of leaking gas. Before lighting, smell all around the appliance area for gas. Be sure to smell next to the floor. IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use

Summary of the content on the page No. 8

Installation (Locating The Water Heater) continued- The water heater must be located close enough to the outside wall to keep the venting distance within the maximum distance described in the vent kit’s installation instructions. Note: The direct vent-air intake terminal must be installed on a vertical wall. Read the instructions from the vent kit that was purchased with the water heater before locating the water heater. This water heater must be located in an area where leakage of

Summary of the content on the page No. 9

OPTIONAL DIRECT VENT-AIR INTAKE TERMINAL GUARD WARNING The direct vent-air intake terminal is HOT while the water heater is in operation. Do not touch. Keep children, combustibles, gasoline and other liquids having flammable vapors away. It is recommended that a vent-air intake terminal guard be installed when the vent-air intake terminal is located where it can be touched accidentally, or accessed by children. (See Figure 2). A chain link or louvered fence may be used instead of

Summary of the content on the page No. 10

Installation continued- Figure 2 Figure 3 10

Summary of the content on the page No. 11

VENTING WARNING The vent-air intake system must be properly installed. Failure to properly install the vent-air intake system could result in property damage, personal injury or death. DO NOT install any damaged vent-air intake system components. Contact the manufacturer of the water heater for replacement parts. This is a Direct Vent Gas Water Heater where all air for combustion is obtained from the outside atmosphere and all flue gases are discharged to the outside atmosphere.

Summary of the content on the page No. 12

Figure 4 Direct Vent Terminal Clearances Canadian Installations1 US Installations2 Clearance above grade, veranda, porch, deck or A= 12 inches (30 m) 12 inches (30 cm) balcony 9 inches (23 cm) for appliances > 10,000 Btuh (3 kW) and ≤ 50,000 B= Clearance to widow or door that may be opened 12 inches (30 m) Btuh (15 kW), 12 inches (30 cm) for appliances > 50,000 Btuh (15 kW) C= Clearance to permanently closed widow *b *b Vertical clearance to ventilated soffit located above

Summary of the content on the page No. 13

Venting continued- 1 In accordance with the current CAN/CGA-B149 Installation Codes. 2 In accordance with the current ANSI Z223.1-(Latest edition)/NFPA 54 National Fuel Gas Code. † A vent must not terminate directly above a sidewalk or paved driveway that is located between two single- family dwellings and serves both dwellings. ‡ Permitted only if a veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. *a) A minimum clearance value determined by t

Summary of the content on the page No. 14

WATER CONNECTIONS Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting off the main water supply, open a faucet to relieve the water line pressure to prevent any water from leaking out of the pipes while making the water connections to the water heater. After the pressure has been relieved, close the faucet. The COLD water inlet and HOT water outlet are identified on the top of the water heater. The fittings at the cold water inlet and h

Summary of the content on the page No. 15

Water Connections continued- WARNING For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements of the Standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Wate

Summary of the content on the page No. 16

Water Connections continued- WARNING FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED 3/4” X 3/4” TEMPERATURE AND PRESSURE RELIEF VALVE WILL RELEASE THE MANUFACTURER FROM ANY CLAIM, WHICH MIGHT RESULT FROM EXCESSIVE TEMPERATURES AND PRESSURES. If this water heater is installed in a closed water supply system, such as the one having a back-flow preventer in the cold water supply, provisions must be made to control thermal expansion. DO NOT operate this water heater in a closed system wi

Summary of the content on the page No. 17

Gas Connections The gas supply lines must meet all requirements of the National Fuel Gas Code (ANSI Z223.1-Latest Edition), or in Canada CAN/CGA B149.1 Natural Gas Installation Code (Latest Edition) or CAN/CGA B149.2 Propane Installation Code (Latest Edition). The minimum permissible gas supply pressure for the purpose of input adjustment is one (1.0) inch (0.25 kPa) water column above the operating manifold pressure. See the rating plate and gas valve for the manifold pressure and g

Summary of the content on the page No. 18

GENERAL OPERATION WARNING Water heaters are heat producing appliances. To avoid damage or injury, do not store materials against the water heater or vent-air intake system. Use proper care to avoid unnecessary contact (especially by children) with the water heater and vent-air intake system. UNDER NO CIRCUMSTANCES MUST FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY LOCATI

Summary of the content on the page No. 19

Lighting & Shutdown Instructions – White Rodgers and Robertshaw gas control. 19

Summary of the content on the page No. 20

Lighting & Shutdown Instructions Continued - Honeywell gas control. 20


Alternative user manuals
# User manual Category Download
1 Honeywell B User manual Water Heater 0
2 Honeywell AQUASTAT L6189A-C User manual Water Heater 1
3 Honeywell BH-777FTE User manual Water Heater 17
4 Honeywell 238-47969-00A User manual Water Heater 0
5 Honeywell 238-47759-00 User manual Water Heater 0
6 Honeywell 75 GALLON ULTRA LOW NOx User manual Water Heater 0
7 Honeywell XLS-278 User manual Water Heater 4
8 Honeywell L8104A User manual Water Heater 0
9 Honeywell L4189A User manual Water Heater 9
10 Honeywell L4188A User manual Water Heater 6
11 Honeywell L8104C User manual Water Heater 0
12 Honeywell L8104B User manual Water Heater 0
13 Honeywell L8104D User manual Water Heater 0
14 Honeywell PDX150S*F(BN,SX,CX) User manual Water Heater 0
15 Honeywell PDX140S*F(BN,SX,CX) User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6