Hobart IB140 ML-110899 user manual

User manual for the device Hobart IB140 ML-110899

Device: Hobart IB140 ML-110899
Category: Water Heater
Manufacturer: Hobart
Size: 0.76 MB
Added : 8/12/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hobart IB140 ML-110899. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hobart IB140 ML-110899.

For your convenience

If looking through the Hobart IB140 ML-110899 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hobart IB140 ML-110899 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hobart IB140 ML-110899 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hobart IB140 ML-110899 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hobart IB140 ML-110899 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hobart IB140 ML-110899. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

I
N
S
T
INFRARED
R
BOOSTER
U
C
T
I
O
N
S
INFRARED BOOSTER
. . . Gas Water Heaters
MODEL
IB57 ML-110898
IB140 ML-110899
IB235 ML-110861
IB290 ML-110862
701 S. RIDGE AVENUE
TROY, OHIO 45374-0001
937 332-3000
– 1 –
www.hobartcorp.com FORM 34070 Rev. C (10-99)

Summary of the content on the page No. 2

IMPORTANT FOR YOUR SAFETY WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor'

Summary of the content on the page No. 3

TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Delivery Rates at 180°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

Installation, Operation, and Care of INFRARED BOOSTER GAS WATER HEATERS SAVE THESE INSTRUCTIONS GENERAL The Infrared Booster Gas Water Heaters (available for natural gas or propane) provide 180°F rinse water for commercial dishwashing machines. Health codes and NSF permit 180°F (minimum temperature) water to be used as a sanitizing rinse for utensils and dishware used in restaurants and food-serving operations. Water enters the gas booster water heater at the inlet water connection, circulates

Summary of the content on the page No. 5

INSTALLATION UNPACKING Immediately after unpacking, check for possible shipping damage. If the Booster Heater is found to be damaged after unpacking, save the packaging material and contact the carrier within 15 days of delivery. Prior to installation, test the electrical service to assure that it agrees with the specifications on the data plate located on the left-front panel of the booster heater. Be sure that the type of gas supplied to the machine (natural gas or propane) is the same as in

Summary of the content on the page No. 6

VENTING REQUIREMENTS WARNING: PROVIDE A SCREEN OR BARRIER TO PREVENT PERSONAL INJURY IN AREAS WHERE INADVERTENT PERSONNEL CONTACT WITH THE HOT VENT PIPE CAN OCCUR. Models IB57 and IB140 are Category IV (positive flue Models IB235 & IB290 Only pressure, excessive condensate, and flue gas temperature at the heater outlet approximately 330°F). Models IB235 and IB290 are Category III (positive flue Water Out pressure, not excessive condensate, and flue gas temperature at the heater outlet approxima

Summary of the content on the page No. 7

Vent Hood Dishwasher Dish Table or Conveyor Vent Pipe 3 to 4 Inch Adapter Required For IB235 and IB290 PL-53441 Fig. 2 Termination Tee Combustible Sidewall Termination Termination Tee Dish Table or Conveyor Dishwasher 6" Thru-Wall Fitting Non-Combustible Sidewall Termination Termination Tee 6" 3 to 4 Inch Adapter Required For IB235 and IB290 PL-53442 Fig. 3 – 7 –

Summary of the content on the page No. 8

Termination Tee Dish Table or Conveyor Vent Pipe 3 to 4 Inch Adapter Required For IB235 and IB290 PL-53443 Fig. 4 1 All horizontal runs of the vent pipe shall have a minimum rise of /4" per foot of length and should be supported every 5 feet or less (for Canada, every 3 feet) and at every elbow. For horizontal venting of models IB57 and IB140, the total length of 3-inch diameter vent pipe can be up to 70 feet with up to four 90° elbows and one termination vent. For horizontal venting of mod

Summary of the content on the page No. 9

NO OFF GAS CONNECTION 1 For model IB57, the gas inlet pipe size is /2" NPT at the gas valve. For models IB140, IB235, and IB290, 3 the gas inlet pipe size is /4" NPT at the gas valve. The gas supply line must be sized to adequately provide the input BTU/Hr rate for that model at the specified flowing pressure (see table). The maximum inlet gas pressure must not exceed GAS PRESSURE SPECIFICATIONS the Max value shown in the chart at right. The [FG F F FFG L L L L LO O O O OW W W W WIIIIIN N N

Summary of the content on the page No. 10

WATER REQUIREMENTS Proper water quality can improve ware washing performance by reducing spotting, lowering chemical supply costs, enhancing effectiveness of labor, and extending equipment life. Local water conditions vary from one location to another. The recommended proper water treatment for effective and efficient use of this equipment will also vary depending on the local water conditions. Ask your municipal water supplier for details about local water specifics prior to installation. Re

Summary of the content on the page No. 11

SHOWN WITH OPTIONAL WATER HAMMER ARRESTOR KIT Union Water Shock Ball Absorber Valve 180 F to Dishwasher Pressure Gauge 140 F Inlet Floor Drain Union Pressure Ball Valve Regulator PL-53294 Fig. 6 The heater is equipped with a pump which circulates water inside the booster heater and maintains a uniform water temperature in the tank. Depending on the distance from the heater to the dishwasher, it may be necessary to run empty rack(s) to purge the supply line if the indicated rinse water tempe

Summary of the content on the page No. 12

ELECTRICAL CONNECTIONS WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES. WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT THE CIRCUIT IS BEING WORKED ON. The electrical power supply requirement for the heater is 120 Volts, 60 Hz, 1 Phase. Minimum conductor ampacity and maximum protective device should be rated 15 Amperes. The electrical power f

Summary of the content on the page No. 13

– 13 –

Summary of the content on the page No. 14

START UP PROCEDURES — FOR YOUR SAFETY READ BEFORE OPERATING Filling the Booster Piping Fill the booster heater with water, purging all air. Make sure water is flowing through the booster to the dishwasher's fill or final rinse before lighting the booster heater by either leaving the main power switch off on Stand Alone units or leaving the manual gas valve closed on Dishwasher Activated units. Checking the Circulator • Before lighting the heater, make sure the water pump is operating properly

Summary of the content on the page No. 15

NO OFF Hot Surface Ignition Using the Robertshaw Gas Valve 1. STOP! Read the safety information. Model IB57 2. Turn off all electrical power to the appliance. 3. Remove the left side panel. Gas Valve Gas Control Knob 4. This appliance is equipped with an ignition device which automatically lights the burners. DO NOT try to light the burners by hand. 5. Turn the gas control knob clockwise to the "OFF" position. 6. Wait five (5) minutes to clear out any gas. If you then smell gas, stop and foll

Summary of the content on the page No. 16

OPERATION The booster heater is designed to deliver 180°F water, up to the gallons per minute and gallons per hour ratings specified in the table on page 4, depending on the incoming water temperature and Booster Heater model and its input BTU/Hr. Provided the necessary power, water, gas, and vent connections are completed, a STAND ALONE unit is started by the activation of the On / Off Switch located on the front (Fig. 9). Provided the necessary power, water, gas, and vent connections are comp

Summary of the content on the page No. 17

MAINTENANCE LUBRICATION The water pump motor and the combustion air blower motor are permanently lubricated and require no other maintenance. VENT SYSTEM Annually check the vent system for obstruction. Check for signs of deformation in the vent pipes which will be an indication of abnormal conditions in the venting system. Refer to the instructions supplied by the vent pipe manufacturer. CHECK BURNER FLAME When the burner is operating properly the flame will appear to be orange with a blue tin

Summary of the content on the page No. 18

LIST OF REPLACEMENT PARTS When ordering parts, be sure to provide the Model Number, ML Number, and Serial Number from the data plate located on the left-front panel of the booster heater. NOTE: As continued product improvement is a policy of the manufacturer, part numbers may change without notification. For the latest part numbers, contact your Hobart-authorized service office. NOTE: 57,000 BTU/Hr, 140,000 BTU/Hr & 235,000 BTU/Hr sizes apply to Natural Gas and Propane; 280,000 BTU/Hr applies t

Summary of the content on the page No. 19

Components (Pump Side) continued PART No. NAME OF PART AMT 5 FP 047-12 FITTING-TUBE /8 TBG FERRULE (140,000 & 235,000 BTU/Hr) . . . . . . . . . . . . . . . . . . . 1 5 FP 012-45 FITTING-TUBE /8 TBG NUT (140,000 & 235,000 BTU/Hr) . . . . . . . . . . . . . . . . . . . . . . . 1 3 1 FP 027-22 BUSHING-PIPE /4 TO /2 (280,000 & 290,000 BTU/Hr) . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 FP 077-27 ADAPTER-PIPE /2 FPT x /2 MPT (280,000 & 290,000 BTU/Hr) . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 20

Components (Pump Side) continued PART No. NAME OF PART AMT 00 294500 040-1 TRANSFORMER, 30VA, 50/60HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 00 294681 028-1 THERMOSTAT, AUTO RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 00 087714 046-1 RELAY (2 POLE, 120 VAC) (1CR, 2CR, 3CR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1 00 294677 00002 CLAMP-WIRE /2 . . . . . . . . . . . . . . . . .


Alternative user manuals
# User manual Category Download
1 Hobart IB235 ML-110861 User manual Water Heater 2
2 Hobart IB290 ML-110862 User manual Water Heater 0
3 Hobart IB57 ML-110898 User manual Water Heater 1
4 A.O. Smith 000 User manual Water Heater 8
5 A.O. Smith 101 User manual Water Heater 3
6 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
7 A.O. Smith 104 Series User manual Water Heater 3
8 A.O. Smith 104 - 110 User manual Water Heater 6
9 A.O. Smith 105 Series User manual Water Heater 1
10 A.O. Smith 15 User manual Water Heater 0
11 A.O. Smith 2100 User manual Water Heater 0
12 A.O. Smith 1850 User manual Water Heater 0
13 A.O. Smith 185874-001 User manual Water Heater 0
14 A.O. Smith 185762-000 User manual Water Heater 0
15 A.O. Smith 2500 User manual Water Heater 1