Desa VANGUARD VVDA30M user manual

User manual for the device Desa VANGUARD VVDA30M

Device: Desa VANGUARD VVDA30M
Category: Water Heater
Manufacturer: Desa
Size: 3.78 MB
Added : 3/9/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa VANGUARD VVDA30M. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa VANGUARD VVDA30M.

For your convenience

If looking through the Desa VANGUARD VVDA30M user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa VANGUARD VVDA30M on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa VANGUARD VVDA30M to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa VANGUARD VVDA30M User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa VANGUARD VVDA30M but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa VANGUARD VVDA30M. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

GAS LOG
TM VENTED DECORATIVE APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
Convertible from Natural Gas
VANGUARD MODELS:
to Propane/LP Gas
VVSA18M, VVSA24M, VVDA18M, VVDA24M and VVDA30M
FOR USE WITH LOG SETS:
Hanover Round Oak Log Models VSLR18 and VSLR24
Kingston Split Oak Log Models VDLCR18, VDLCR24 (Shown)
and VDLCR30
FMI MODELS:
FVSA18M, FVSA24M, FVDA18M, FVDA24M and FVDA30M
FOR USE WITH LOG SETS:
Arlington Round Oak Log Models FSLR18 and FSLR24
Manchester Split Oak Log Models FDLCR18,

Summary of the content on the page No. 2

TABLE OF CONTENTS SAFETY INFORMATION 2 TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 INSPECTING BURNERS.......................................................... 10 LOCAL CODES ........................................................................... 3 CLEANING AND MAINTENANCE ............................................ 10 PRODUCT IDENTIFICATION ..................................................... 3 TROUBLESHOOTING .......................

Summary of the content on the page No. 3

SAFETY INFORMATION 3 LOCAL CODES 3 PRODUCT IDENTIFICATION UNPACKING PRODUCT FEATURE SAFETY INFORMATION PRODUCT IDENTIFICATION Continued Grate Steps 9. Do not use a blower insert, heat exchanger insert or other ac- Grate cessory not approved for use with this log set. 10. The installation and provisions for combustion and ventilation air must conform with the National Fuel Gas Codes, ANSI Z233.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation. 11. Do not run log set • where flammable li

Summary of the content on the page No. 4

INSTALLATION Flue Opening Specifications 4 Check Gas Type Venting Specifications for Installation INSTALLATION CHECK GAS TYPE CAUTION: Do not remove the metal data plates Use only natural gas. If your gas supply is not natural gas, you attached to the burner pan. The data plates contain must convert the appliance to propane/LP. Follow the instruc- important warranty and safety information. tions on pages 6 and 7. If the fireplace does not have a gas supply shut-off valve, one must WARNING: Bef

Summary of the content on the page No. 5

INSTALLATION 5 Installing Damper Clamp 5 INSTALLATION Continued INSTALLING DAMPER CLAMP Installation must include an equipment shutoff valve, union, and Secure the damper stop clamp provided to the leading edge of the plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge damper as shown in Figure 3. If for any reason this clamp doesn't hook up. NPT tap must be upstream from log set (see Figure 4). work on your fireplace, another suitable clamp or permanent stop must be installed, or t

Summary of the content on the page No. 6

INSTALLATION Checking Gas Connections 6 Hearth Pan Installation INSTALLATION Continued CHECKING GAS CONNECTIONS HEARTH PAN INSTALLATION If using propane/LP gas, see Propane/LP Gas Conversion before WARNING: Test all gas piping and connections installing hearth pan. for leaks after installing or servicing. Correct all leaks 1. Place the burner pan assembly in the center of the fireplace at once. floor. Make sure the front of pan faces forward. 2. Thread the gas supply fitting to the fireplace ga

Summary of the content on the page No. 7

INSTALLATION 7 Hearth Pan Installation (Cont.) 7 INSTALLATION Continued 4. Using a wrench, remove gas control valve and burner inlet 9. To adjust regulator pressure, remove the brass hex plug from fitting by turning counterclockwise (see Figure 8). regulator (see Figure 10). 5. Remove the burner inlet fitting from the gas control assembly 10. Remove the plastic pressure button from the brass plug (see (see Figure 8). DO NOT remove the orifice from this fitting. Figure 10). The propane/LP burner

Summary of the content on the page No. 8

INSTALLATION Testing Burner for Leaks 8 Adding Pan Material Installing the Grate and Logs INSTALLATION Continued Grate Steps TESTING BURNER FOR LEAKS Grate 1. Generously apply noncorrosive leak detection fluid to all connections. WARNING: Never check for gas leaks with open flame. 2. Light the burner with the shutoff valve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 9). 3. Inspect all connections for bubbles, raw gas odor, or flame fr

Summary of the content on the page No. 9

ON OFF FROM "PILOT" POSITION SLIGHT PUSH TO TURN OFF PULL PUSH OPERATING APPLIANCE 9 For Your Safety Read Before Lighting 9 Curing Logs Lighting Instructions To Turn Off Gas To Appliance OPERATING APPLIANCE LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING 1. STOP! Read the safety information, column one. 2. Make sure equipment shutoff valve is fully open. 3. Press in and turn control knob clockwise to the WARNING: Keep flue open when operating unit. OFF position. 4. Wait five (5) mi

Summary of the content on the page No. 10

OPERATING APPLIANCE To Turn Off Gas To Appliance 10 INSPECTING BURNERS Pilot Assembly Burner Flame Pattern CLEANING AND MAINTENANCE OPERATING APPLIANCE Continued BURNER FLAME PATTERN Burner flames will be steady; not lifting or floating. Flames should TO TURN OFF GAS TO APPLIANCE go up through the middle of logset. Flames should not "spill" to the edges of the pan or sides of the logset. Shutting Off Appliance Figure 18 shows a typical flame pattern. If burner flame pattern differs 1. Turn contr

Summary of the content on the page No. 11

TROUBLESHOOTING 11 11 TROUBLESHOOTING Note: For additional help, visit DESA International’s technical WARNING: Turn off log set and let cool before service web site at www.desatech.com. servicing. Only a qualified service person should Note: All troubleshooting items are listed in order of operation. service and repair log set. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Log set is smoking/sooting excessively 1. Poor fuel quality 1. Contact local natural or propane/LP gas (Note: It is natural and un

Summary of the content on the page No. 12

TROUBLESHOOTING 12 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot lights but flame goes out when 1. Control knob not fully pressed in 1. Press in control knob fully control knob is released 2. Control knob not pressed in long enough 2. After pilot lights, keep control knob pressed in 30 seconds 3. Equipment shutoff valve not fully open 3. Fully open equipment shutoff valve 4. Pilot flame not touching thermocouple, 4. A) Contact local natural or propane/LP which allows the

Summary of the content on the page No. 13

TROUBLESHOOTING 13 13 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating log set where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, c

Summary of the content on the page No. 14

ILLUSTRATED PARTS BREAKDOWN VVSA18M, VVSA24M, VVDA18M, VVDA24M and VVDA30M 14 ILLUSTRATED PARTS BREAKDOWN VVSA18M, VVSA24M, VVDA18M, VVDA24M AND VVDA30M 9 9 10 7 12 5 11 27 17 5 22 23 6 24 4 3 20 16 21 13 15 2 19 14 18 25 8 1 26 For more information, visit www.desatech.com For more information, visit www.desatech.com 901268

Summary of the content on the page No. 15

PARTS LIST 15 VVSA18M, VVSA24M, VVDA18M, VVDA24M and VVDA30M 15 PARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY PART NUMBER NO. VVSA18M VVSA24M VVDA18M VVDA24M VVDA30M DESCRIPTION QTY. 1 901063-01 901063-01 901063-01 901063-01 901063-01 Brass 3/8 FLR x 1/2 FPT 1 2 901056-01 901056-01 901056-01 901056-01 901056-01 Brass 3/8 FLR x 3/8 MPT Elbow 1 3 901066-01 901066-01 90

Summary of the content on the page No. 16

ILLUSTRATED PARTS BREAKDOWN VSLR18, VSLR24, VDLCR18, VDLCR24, and VDLCR30 16 ILLUSTRATED PARTS BREAK- DOWN 8 LOG SET MODELS 6 7 VSLR18, VSLR24, VDLCR18, 5 VDLCR24, AND VDLCR30 4 9 1 3 15 2 12 Kingston Split Oak Logs 13 14 10 11 Hanover Round Oak Logs For more information, visit www.desatech.com For more information, visit www.desatech.com 901268

Summary of the content on the page No. 17

PARTS LIST 17 VSLR18, VSLR24, VDLCR18, VDLCR24, and VDLCR30 17 PARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY PART NUMBER NO. VSLR18 VSLR24 VDLCR18 VDLCR24 VDLCR30 DESCRIPTION QTY. 1 — — 901565-02 901566-02 901567-02 Bottom Rear 1 2 — — 901603-01 901604-01 901604-04 Bottom Front 1 3 — — 901593-01 901594-01 901595-01 Bottom Front 1 4

Summary of the content on the page No. 18

ILLUSTRATED PARTS BREAKDOWN FVSA18M, FVSA24M, FVDA18M, FVDA24M and FVDA30M 18 ILLUSTRATED PARTS BREAKDOWN MODELS FVSA18M, FVSA24M, FVDA18M, FVDA24M AND FVDA30M 9 9 10 7 12 5 27 11 17 5 22 23 6 24 4 3 20 16 21 13 15 2 19 14 18 25 8 1 26 For more information, visit www.desatech.com For more information, visit www.desatech.com 901268

Summary of the content on the page No. 19

PARTS LIST 19 FVSA18M, FVSA24M, FVDA18M, FVDA24M and FVDA30M 19 PARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY PART NUMBER FOR NO. FVSA18M FVSA24M FVDA18M FVDA24M FVDA30M DESCRIPTION QTY. 1 901063-01 901063-01 901063-01 901063-01 901063-01 Brass 3/8 FLR x 1/2 FPT 1 2 901056-01 901056-01 901056-01 901056-01 901056-01 Brass 3/8 FLR x 3/8 MPT Elbow 1 3 901066-01 901066-0

Summary of the content on the page No. 20

ILLUSTRATED PARTS BREAKDOWN FSLR18, FSLR24, FDLCR18, FDLCR24 and FDLCR30 20 ILLUSTRATED PARTS BREAKDOWN 8 LOG SET MODELS FSLR18, FSLR24, FDLCR18, FDLCR24 AND FDLCR30 7 6 4 5 1 3 9 15 2 Manchester Split Oak Logs 12 14 10 13 11 Arlington Round Oak Logs For more information, visit www.desatech.com For more information, visit www.desatech.com 901268


Alternative user manuals
# User manual Category Download
1 Desa VANGUARD VVDA30M User manual Marine Radio 0
2 Desa 15 User manual Water Heater 0
3 Desa 6000 BTU/HR User manual Water Heater 2
4 Desa and CVDR30 User manual Water Heater 0
5 Desa B User manual Water Heater 0
6 Desa A, C, B User manual Water Heater 0
7 Desa CBT30NT, CBT30PT User manual Water Heater 0
8 Desa CBN20T User manual Water Heater 0
9 Desa CCL3018NTA User manual Water Heater 0
10 Desa CCL3018NA User manual Water Heater 0
11 Desa CCL3018PTA User manual Water Heater 0
12 Desa CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB User manual Water Heater 0
13 Desa CCL3924NA User manual Water Heater 0
14 Desa CCL3924NTA User manual Water Heater 0
15 Desa CCL3930NTB User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6