A.O. Smith ADMP - 90 user manual

User manual for the device A.O. Smith ADMP - 90

Device: A.O. Smith ADMP - 90
Category: Water Heater
Manufacturer: A.O. Smith
Size: 0.84 MB
Added : 10/20/2013
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for A.O. Smith ADMP - 90. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with A.O. Smith ADMP - 90.

For your convenience

If looking through the A.O. Smith ADMP - 90 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual A.O. Smith ADMP - 90 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual A.O. Smith ADMP - 90 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
A.O. Smith ADMP - 90 User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual A.O. Smith ADMP - 90 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to A.O. Smith ADMP - 90. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ADMP / ADM / ADMR
Atmospheric commercial
water heater
ADMP / ADM / ADMR - 40/50/60/80/90/115/135
An extensive range of atmospheric water heaters to suit most
larger hot water systems • Effi cient, automatic hot surface igniter
• Removable control column for convenient servicing • Frost-
protection thermostat • Stainless steel burner for natural or LP gas
• Two access covers for comprehensive waterside tank maintenance
• External control connection • Voltage-free contact for general
fault

Summary of the content on the page No. 2

ADMP / ADM / ADMR Technical specifications Gas data natural gas 2H (G20) Input* kW 42.2 56.5 66.4 82.5 98.3 126.6 143.4 42.2 56.5 66.4 82.5 98.3 126.6 143.4 Output kW 32.3 42.8 50.2 62.4 74.3 95.8 109.8 32.3 42.8 50.2 62.4 74.3 95.8 109.8 Inlet pressure mbar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Burner pressure mbar 8.5 8.5 8.5 8.5 8.5 8.5 11.3 8.5 8.5 8.5 8.5 8.5 8.5 11.3 3 Gas consumption** m /h 4.0 5.4 6.3 7.9 9.4 12.1 13.7 4.0 5.4 6.3 7.9 9.4 12.1 13.7 Diameter main orifice mm 3

Summary of the content on the page No. 3

ADMP / ADM / ADMR Dimensions ADM / ADMR A 1900 2100 1900 2100 2000 2085 2085 B 1760 1960 1760 1960 1795 1870 1870 D 710 710 710 710 710 710 710 E 800 800 800 800 800 800 800 F 1100 1100 1100 1100 1105 1105 1105 G 150 150 180 180 225 225 225 H 660 660 660 660 675 675 675 J 1840 2040 1840 2040 1935 2010 2010 K 400 400 400 400 400 400 205 M 565 565 565 565 575 650 650 N 1605 1810 1605 1810 1640 1715 1715 P 730 730 730 730 740 825 855 R 500 515 500 515 525 600 595 S 1550 1760 1550 1760 1595 1660 16

Summary of the content on the page No. 4

ADMP / ADM / ADMR Installation diagrams ADM / ADMR 1 Pressure reducing valve Vented 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 7 Destratifi cation pump 9 Drain valve 10 Gas cock 11 Isolating valve 12 Temperature gauge 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve A Cold water B Hot water C Return circulation D Gas supply E Overfl ow pipe H Expansion vent pipe Unvented A.O. Smith unv

Summary of the content on the page No. 5

ADMP / ADM / ADMR Electrical diagram ADM TERMINAL STRIP CONNECTIONS Earth N Neutral L1 Phase input of controller L2 Phase input of flue gas thermostat L3 Phase output of flue gas thermostat COMPONENTS A Two-terminal main switch B Flue gas thermostat C Indicator LED “Error” D Indicator LED “Running” E “RESET” button F Burner control G Control thermostat H Frost thermostat J 0/1 switch of controller K Safety thermostat L High-limit thermostat M Extra error sensor N Gas con

Summary of the content on the page No. 6

ADMP / ADM / ADMR Electrical diagram ADMR TERMINAL STRIP CONNECTIONS Earth N Neutral L1 Phase input of controller L2 Phase input of program- controlled pump L3 Phase input of continuous pump L4 Phase input of extra error signal L5 Phase input of flue damper motor L6 Phase output of flue damper motor (feedback) L7 Phase input of isolating transformer (primary side) L8 Phase output of isolating transformer (secondary side) COMPONENTS A Controller B Gas control C Glow igni


Alternative user manuals
# User manual Category Download
1 A.O. Smith 000 User manual Water Heater 8
2 A.O. Smith 101 User manual Water Heater 3
3 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
4 A.O. Smith 104 Series User manual Water Heater 3
5 A.O. Smith 104 - 110 User manual Water Heater 6
6 A.O. Smith 105 Series User manual Water Heater 1
7 A.O. Smith 15 User manual Water Heater 0
8 A.O. Smith 2100 User manual Water Heater 0
9 A.O. Smith 1850 User manual Water Heater 0
10 A.O. Smith 185874-001 User manual Water Heater 0
11 A.O. Smith 185762-000 User manual Water Heater 0
12 A.O. Smith 2500 User manual Water Heater 1
13 A.O. Smith 184769-000 User manual Water Heater 1
14 A.O. Smith 1300 User manual Water Heater 0
15 A.O. Smith 197835-001 User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6