A.O. Smith BTPN user manual

User manual for the device A.O. Smith BTPN

Device: A.O. Smith BTPN
Category: Water Heater
Manufacturer: A.O. Smith
Size: 0.26 MB
Added : 9/27/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for A.O. Smith BTPN. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with A.O. Smith BTPN.

For your convenience

If looking through the A.O. Smith BTPN user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual A.O. Smith BTPN on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual A.O. Smith BTPN to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
A.O. Smith BTPN User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual A.O. Smith BTPN but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to A.O. Smith BTPN. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODELS BTP-140-140 thru 600-2500
INCLUDING BTPD/BTPN/COF & COBT
COMMERCIAL GAS, OIL AND GAS/OIL TANK-TYPE WATER HEATERS
• INSTALLATION • OPERATION • SERVICE • MAINTENANCE • LIMITED WARRANTY
®
CONSERVATIONIST
ASME
CAUTION
TEXT PRINTED OR OUTLINED IN RED CONTAINS
INFORMATION RELATIVE TO YOUR SAFETY.
PLEASE READ THOUROUGHLY BEFORE USING
APPLIANCE.
A DIVISION OF A.O. SMITH CORPORATION
RENTON, WASHINGTON
www.hotwater.com
WARNING – PROPANE MODEL
Water heaters for propane gas are different from natu

Summary of the content on the page No. 2

FOREWORD This manual is intended to be used in conjunction with other ARRANGEMENT REQUIREMENTS AND SERVICE literature provided with the heater. This includes power burner RECOMMENDATIONS. and related gas control information. It is important that this manual and the additional publications be reviewed in their entirety before In the absence of local codes, the installation must comply with beginning any work. the instruction as outlined in the latest publication of ANSI booklet NFPA-54/ANSI Z22

Summary of the content on the page No. 3

The venting of the water heater should be inspected by a qualified GENERAL SAFETY service technician at the time of installation and periodically thereafter to ensure a down-draft condition does not exist. INFORMATION DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATING AIR. ADEQUATE AIR FOR COMBUSTION AND PRECAUTIONS VENTILATION MUST BE PROVIDED FOR SAFE OPERATION. DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDERWATER. Immediately call a qualified service technician LIQUID PETROLEUM MOD

Summary of the content on the page No. 4

Note: Some gas utility companies derate the heating value of the The water temperature is controlled by two thermostats. One supplied gas at high elevations. Your authorized A.O. Smith Start- thermostat is located near the top of the tank and the other is in Up Agent must adjust for actual heating valve of the gas at the the lower part of the tank. The upper thermostat must be set at time of start-up. least 5°F higher than the lower thermostat. In the case where the water heater has electro

Summary of the content on the page No. 5

The latest version of the National Electrical Code, NFPA No. A clearance of 24” should be maintained from serviceable parts, 70. In Canada refer to Canadian Electrical Code C 22.1, from such as relief valve, power burner, thermostat and drain valve. National Fire Protection Association, 1 Batterymarch Park, MINIMUM INSTALLATION CLEARANCES Quicy, MA 02269-9101. BTP/BTPN/BTPD COF/COBT LOCATING THE HEATER FRONT - 18 Inches FRONT - 18 Inches BACK - 0 Inches Back - 6 Inches When installing the heate

Summary of the content on the page No. 6

UNDESIRABLE OPENINGS, CAUSING POOR COMBUSTION. VENT CONNECTOR SOOTING MAY RESULT WITH AN INCREASED RISK OF ASPHYXIATION. The chimney vent connector diameter should be the same size as the heater flue outlet, see table 1. A minimum rise of 1/4” per THERMAL EXPANSION (CLOSED SYSTEM) foot of horizontal connector length must be maintained between the heater and chimney opening, fig. 2. The connector length Thermal expansion occurs in any hot water system when system should be kept as short as pos

Summary of the content on the page No. 7

TABLE 2 CAPACITY OF PIPE - NATURAL GAS IN CUBIC FEET PER HOUR Maximum Based Upon Pressure Drop of 0.3” w.c. and Specific Gravity CORRECTION FACTORS of 0.60 and Maximum Gas Pressure of .5 psig. Specific Gravity Pressure Drop Pipe Length Pipe Size - Inches (IPS) Other than 0.60 Other than 0.3 In Feet 1 1 1/4 1 1/2 2 2 1/2 3 4 Specific Multplier Pressure Multiplier 10 520 1050 1600 3050 4800 8500 17500 Gravity Drop 20 350 730 1100 2100 3300 5900 12000 0.50 1.10 0.1 0.577 30

Summary of the content on the page No. 8

TABLE 3 PURGING EQUIVALENT LENGTH OF FITTINGS IN FEET Gas line purging is required with new piping or systems in which Pipe Size (IPS) 1 1.25 1.5 2 2.5 3 4 air has entered. Std. Tee through side 5.5 7.5 9.0 12.0 14.0 17.0 22.0 Std. E11 2.7 3.7 4.3 5.5 6.5 8.0 12.0 45°F E11 1.2 1.6 2.0 2.5 3.0 3.7 5.0 CAUTION Plug Cock 3.0 4.0 5.5 7.5 9.0 12.0 16.0 PURGING SHOULD BE PERFORMED BY PERSONS EXPERIENCED IN THIS TYPE GAS SERVICE. TO AVOID RISK OF FIRE OR EXPLOSION, PURGE DISCHARGE MUST NOT WARNING

Summary of the content on the page No. 9

TYPICAL WIRE DIAGRAM BTP, 270 - 2,500 KBTUH COF, 800 - 2,500 KBTUH COBT, 400 - 2,500 KBTUH TYPICAL WIRE DIAGRAM BTP, 140 - 255 KBTUH 9

Summary of the content on the page No. 10

TYPICAL WIRE DIAGRAM COBT, 140 - 300 KBTUH TYPICAL WIRE DIAGRAM COF, 140 - 720 KBTUH 10

Summary of the content on the page No. 11

OF ELECTRICAL SHOCK. DO NOT ENERGIZE THE BRANCH The Authorized Start-Up Agent will when they come out to start- CIRCUIT BEFORE THE HEATER TANK IS FILLED WITH up the unit(s) complete one of the following forms for each unit WATER. you have and submit it to A.O. Smith Water Products Company to activate your warranty: Start-Up Covering Models TWO UNIT MANIFOLD Form No. 09063511 BTP Models, 140 - 255 kBTUH INSTALLATION 09063510 BTP Models, 270 - 2500 kBTUH 09063512 COBT Models, 140 - 2500 kBTUH 0906

Summary of the content on the page No. 12

3. The correct test instruments are: MAINTENANCE SCHEDULE Component Operation Interval Required •CO indicator or 0 analyzer 2 2 Flushing Monthly Sediment • CO indicator Tank Removal Semi-Annually ® Lime Scale UN•LIME • Stack thermometer Removal As Required Delimer Relief Valve Inspect Semi-Annually • Draft gauge or inclined manometer Power Burner SAE No. 20 Motor(1) Inspect Quarterly non-detergent • U-tube manometer or calibrated 0-10” and 0-35” w.c. motor oil pressure gauge Power Burner Combust

Summary of the content on the page No. 13

Lime accumulation not only reduces the life of the equipment but A. O. Smith Form no. 4800, entitled, “Why, When and How”, also reduces efficiency of the heater and increases fuel describes tank cleaning methods and materials. UN•LIME and consumption. the booklet may be obtained through your A. O. Smith dealer or distributor. To clean heater through cleanout opening, proceed as follows: 1. Turn off water inlet valve, the heater electrical disconnect switch and open drain valve. 2. Remove outer

Summary of the content on the page No. 14

BURNER AIR OPENINGS OR VENTILATION GRILLES FOR To test gate for operation, gently tap gate and observe. DO NOT COMBUSTION AIR. REMOVE LINT ACCUMULATION FROM OIL. AIR INTAKE GRILL. The red solid fuel tabs supplied with the draft regulator must be removed (See instructions supplied with Draft Regulator). At least annually, contact a qualified service agency for burner cleaning and other routine maintenance. CLEANING FLUES-COF & COBT ONLY TROUBLESHOOTING The following describes how to gain access

Summary of the content on the page No. 15

WATER HEATER MAKES NOISE When such a condition is encountered, local codes or inspection agency should be consulted to determine which 1. Sediment or lime scale accumulations cause noises when the system is acceptable in your area. These may consist of: heater is operating. • Installation of a second relief valve with lower setting than • The sounds are normal, however, the tank bottom should the primary relief valve. be cleaned. Refer to MAINTENANCE for details. 2. Some of the electrical comp

Summary of the content on the page No. 16

Model BTP/BTPD/BTPN/COF/COBT Limited Warranty CERTIFIED FACTORY START - UP REQUIRED To activate your warranty, contact your local sales representative or Authorized Start-up Agent to arrange for a FREE Certified Start-up. A.O. Smith Corporation, the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater. 1. THE TANK If the glass lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water the


Alternative user manuals
# User manual Category Download
1 A.O. Smith 000 User manual Water Heater 8
2 A.O. Smith 101 User manual Water Heater 3
3 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
4 A.O. Smith 104 Series User manual Water Heater 3
5 A.O. Smith 104 - 110 User manual Water Heater 6
6 A.O. Smith 105 Series User manual Water Heater 1
7 A.O. Smith 15 User manual Water Heater 0
8 A.O. Smith 2100 User manual Water Heater 0
9 A.O. Smith 1850 User manual Water Heater 0
10 A.O. Smith 185874-001 User manual Water Heater 0
11 A.O. Smith 185762-000 User manual Water Heater 0
12 A.O. Smith 2500 User manual Water Heater 1
13 A.O. Smith 184769-000 User manual Water Heater 1
14 A.O. Smith 1300 User manual Water Heater 0
15 A.O. Smith 197835-001 User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6