Aquacal 101 user manual

User manual for the device Aquacal 101

Device: Aquacal 101
Category: Heat Pump
Manufacturer: Aquacal
Size: 3.05 MB
Added : 1/16/2014
Number of pages: 214
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Aquacal 101. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Aquacal 101.

For your convenience

If looking through the Aquacal 101 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Aquacal 101 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Aquacal 101 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Aquacal 101 User manual - Online PDF
Advertisement
« Page 1 of 214 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Aquacal 101 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Aquacal 101. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODEL / SERIAL NUMBER
- and -
Models:
100, 110, 120, 135 & 155
101,111,121,156
HEA T ONL Y
and
HEA T - COOL
Additional Labels:
South Beach
Caribbean
Fox Smart
Tropez
Multi-Language
(English-Spanish-French)
Pool & Spa Heat Pump
Owner’s Manual and Installation Guide
Attention Installer: This manual is purchaser’s property; leave with heat pump owner!
1
PN: LTP0030
3/17/08

Summary of the content on the page No. 2

NOTES ___________________________________________________________________________________ __________________________________________________________________________________ ___________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _______________________________________________________________________________

Summary of the content on the page No. 3

1-800-786-7751 TABLE OF CONTENTS WELCOME TO THE TEAM ----------------------------------------------5 IMPORTANT FEATURES OF YOUR NEW HEAT PUMP ------------------6 HOW A HEAT PUMP WORKS ------------------------------------------7 SAFETY INFORMATION------------------------------------------------8 QUICK START & STOP-------------------------------------------------10 HEATER CONTROLS ---------------------------------------------------12 Control Panel Layout ----------------------------------

Summary of the content on the page No. 4

TABLE OF CONTENTS (CONTINUED) MAINTENANCE AND GENERAL OPERATION...CONTINUED: Heating Tips--------------------------------------------------------21 - Heating in Cooler Weather--------------------------------------21 Pool/Spa Blankets-----------------------------------------------21 Pool & Spa Combination Heating -------------------------------21 Spa Set-Back Option -------------------------------------------21 Calculating Initial Heating Time-----------------------------------22 Seasonal Use & S

Summary of the content on the page No. 5

Welcome to the eam T Dear Owner: ongratulations on your wise decision to make an AquaCal heat pump part of C your home. Since 1981, AquaCal has maintained the worldwide lead in the manufacture of swimming pool & spa heat pumps. Your new heat pump is not only a great investment, but also the most cost effective method available for heat- “You can rest assured ing pools and spas. For example, your knowing your new heat heat pump is up to 400% more efficient than gas, and, when compared to elec- pu

Summary of the content on the page No. 6

Important Features of Your New Heat Pump ® ThermoLink Heat Exchanger ® The heart of your heat pump is the patented ThermoLink heat exchanger. One of the primary causes of premature heat pump demise is the failure of the heat exchanger. Ordinary heat exchangers are made from a cupronickel alloy. This cupronickel material is susceptible to attack from the sanitizers used in pools and spas and from other related water chemistry conditions. Once the heat exchanger fails, the heat pump is ruined. Th

Summary of the content on the page No. 7

COOL WATER IN WARMED WATER OUT HOWA HEAT PUMP WORKS THE FOLLOWING EXPLANATION IS PROVIDED TO HELP YOU IN UNDERSTANDING WHAT TO EXPECT FROM YOUR HEAT PUMP… A Heat Pump Does Not Make Heat… Heat pumps are so extraordinarily efficient because they do not need to produce heat in order to warm pool or spa water. Rather, heat pumps simply transfer heat from the outside air into the water. If one considers Absolute Zero (the point where all heat is absent) occurs at -459º Fahrenheit, it becomes evident

Summary of the content on the page No. 8

SAFETY INFORMATION Used and maintained properly, your heat pump will provide year-upon-year of safe and economical service. However, as with any mechanical or electrical device, to get the most from your heat pump–while insuring personal safety for you and others–certain operational and maintenance factors must be observed. Likewise, excepting a few minor owner-capable maintenance items (explained later in this manual), repair and service of your heat pump must be performed only by experi- enced

Summary of the content on the page No. 9

Notice: Heater NOT Repairable by Owner Failure to heed the following may result in permanent WARNING ! injury or death. Heat pumps contain no owner-repairable components. Repairs must not be attempted by untrained and/or unqualified individuals. If service is deemed necessary, contact installing dealer or AquaCal Customer Support at (800) 786-7751. Refrigerant Circuit Service Only by Qualified, EPA Certified Technician Failure to heed the following may result in permanent WARNING ! injury or de

Summary of the content on the page No. 10

HEATING- QUICK START & STOP This brief information is provided as an aide to installers, service personnel, and owners. The intent of this section is to provide rapid access to very basic operational information. Individuals who will be routinely using, installing, maintaining, and servicing this heat pump, are strongly encouraged to read this entire manual. Herein, the terms: Heat Pump, Heater, and Unit are used synonymously. These instructions are intended for local control of a heat pump, in

Summary of the content on the page No. 11

HEATING-QUICK START & STOP (continued): 3. To Begin Heating: A. Verify MODE is set to: HEAT (HEA); then, depending on which body of water is to be heated, use the POOL / SPA selector key to select POOL or SPA. B. Position water valves to flow water from the pool or spa, through the heater, and back to the pool or spa. C. Start the water pump; the fan will start, and after 4-minute time delay the unit will begin heating. The selected body of water will be brought to temperature and maintained pe

Summary of the content on the page No. 12

HEATER CONTROLS Control Panel Layout (APPEARANCE VARIES BY MODEL) Control Buttons, Indicator Lights, & Display (AS INDICATED BY CIRCLED NUMBERS) 1) POOL / SPA SELECTOR – Selects either pool or spa thermostat. 2) COOLING INDICATOR LIGHT – Indicates unit is cooling. (Note: this light nonfunctional with heat-only models.) o 3) UP ARROW – Increases temperature setting. (Maximum setting is 104 F) o 4) DOWN ARROW – Decreases temperature setting. (Minimum setting is 45 F) 5) HEATING INDICATOR LIGHT – I

Summary of the content on the page No. 13

HEATER CONTROLS...continued Operational & Programming Codes THE FOLLOWING CODES WILL BE DISPLAYED AS PART OF THE NORMAL OPERATION OF THE HEATER: FLO..... No Water Flow Detected. This code appears whenever the circulating pump is off, or when the heater is not receiving correct water flow. OFF..... System is Off. This code appears whenever heater has been turned off via the mode o selector button, or when the temperature set point has been lowered below 45 F. CFI...... Celsius/Fahrenheit Selectio

Summary of the content on the page No. 14

HEATER CONTROLS...continued Start Up & Setting Operating Controls Owner-Level Programming Instructions (Complete) Covered within this section are features and settings typically accessed first by the installer, and then remaining accessible by the end user (the owner). These features reside at the Level-1 access point within the microprocessor. Note: if preferred, all programming may be performed without water flow, waiting to start the water pump as the last step in the set up and run process.

Summary of the content on the page No. 15

HEATER CONTROLS...continued Start Up & Setting Operating Controls Owner-Level Programming Instructions... continued: 4. Selecting Pool/Spa Thermostat Settings: A. Press the [POOL/SPA] key to toggle between the pool and the spa temperature set points. B. The pool/spa LED indicator lights, located to the left of the temperature display, will confirm the selected set point. 5. Changing The Pool Temperature Set Point: A. Using the [POOL/SPA] key, select the POOL temperature set point. The pool set p

Summary of the content on the page No. 16

HEATER CONTROLS...continued Start Up & Setting Operating Controls Owner-Level Programming Instructions... continued: 8. User Lock Code Option [ULC]...continued: A. Selecting ULC Option: 1) Press either the UP or DOWN ARROW keys; if “LOC” is momentarily displayed followed by “0”, the ULC feature is enabled. If “0” displays proceed to “6)” of this section; otherwise, see number “2,” below. 2) Simultaneously press and hold both the [UP ARROW] and [DOWN ARROW] keys until [CF1] (Celsius / Fahrenheit)

Summary of the content on the page No. 17

HEATER CONTROLS...continued Start Up & Setting Operating Controls Owner-Level Programming Instructions... continued: C. User Lock Code is Activated, but Pass Number is Not Known (“Back Door Entry”): Note: Should the ULC option be enabled, and a lock code number other than the factory default (0) be installed but is unknown, the following procedure may be followed to regain controller programming access: 1) Simultaneously press and hold the [POOL/SPA] and [UP ARROW] keys until the display shows “

Summary of the content on the page No. 18

MAINTENANCE & OPERATIONAL RECOMMENDATIONS The information in this section is written primarily for the Home Owner, but may also apply to servicing dealers or HVAC service centers. This section contains information concerning planned maintenance, proper water flow, maintaining proper clearances, as well as other vital information. Please read this section now, and before calling AquaCal Customer Support (800-786-7751). General Maintenance Heat pumps should be inspected and maintained on an ann

Summary of the content on the page No. 19

MAINTENANCE & OPERATION (continued) Maintain Proper Water Flow • It is important to operate and maintain the filter according to the manufacturer's specifications. As a filter gets dirty, the water flow to the heat pump is reduced. The higher the pressure on the filter gauge, the lower the flow rate. • Similar to a dirty filter, large amounts of debris in the pump and skimmer baskets can reduce water flow. Keep baskets free of debris. • Check for improper valve settings. A partially closed valv

Summary of the content on the page No. 20

MAINTENANCE & OPERATION (continued) Control Irrigation and Storm Run Off • Control Irrigation: In regions were wells are used for irrigation, water quality is sometimes poor, and water spray can damage heater components. Regardless of water quality, it is important that irrigation be directed away from the heat pump. • Prevent rain water runoff from pouring directly into the heater. The heater is designed to withstand normal rainfall, but solid streams of water from roof drip-lines may eventual


Alternative user manuals
# User manual Category Download
1 Aquacal H120 User manual Heat Pump 3
2 Aquacal 75 User manual Heat Pump 5
3 Aquacal H/AT100R User manual Heat Pump 2
4 Aquacal 100 User manual Heat Pump 2
5 Aquacal 55 User manual Heat Pump 4
6 Aquacal H100 User manual Heat Pump 1
7 Aquacal AT120 User manual Heat Pump 6
8 Aquacal LTP0024 User manual Heat Pump 1
9 Aquacal 110 User manual Heat Pump 2
10 Aquacal 120 User manual Heat Pump 3
11 Aquacal 121 User manual Heat Pump 2
12 Aquacal 135 User manual Heat Pump 7
13 Aquacal 155 User manual Heat Pump 9
14 Aquacal 156 User manual Heat Pump 2
15 Aquacal T115 User manual Heat Pump 17
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5