American Standard TWE100AD**E user manual

User manual for the device American Standard TWE100AD**E

Device: American Standard TWE100AD**E
Category: Heat Pump
Manufacturer: American Standard
Size: 2.15 MB
Added : 1/16/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Standard TWE100AD**E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Standard TWE100AD**E.

For your convenience

If looking through the American Standard TWE100AD**E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Standard TWE100AD**E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Standard TWE100AD**E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Standard TWE100AD**E User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Standard TWE100AD**E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Standard TWE100AD**E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation
Operation
Maintenance
Split System Cooling or
Heat Pump Air Handler
7½ - 20 Tons
Model TWE
Models (60 Hz) Models (50 Hz)
TWE060A***E TWE050AD**E
TWE060B***E TWE075AD**E
TWE090A***E TWE100AD**E
TWE090B***E TWE100BD**E
TWE120A***F TWE155BD**E
TWE120B***E TWE200BD**F
TWE180B***E
TWE240B***F
October 2006 TWE-SVX03C-EN

Summary of the content on the page No. 2

Preface and Warnings and Cautions Literature Change History Warnings and Cautions TWE-SVX03A-EN (June 2003) Notice that warnings and cautions Implemented Global Graphics format appear at appropriate intervals to IOM. throughout this manual. Warnings TWE-SVX03B-EN (April 2005) are provided to alert installing Added capacitor discharge warning. contractors to potential hazards that could result in personal injury or TWE-SVX03C-EN (September 2006) death, while cautions are designed to Mo

Summary of the content on the page No. 3

Contents Model Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Unit Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Inspection

Summary of the content on the page No. 4

Model Number Description TWE 090 A 1 00 E A 123 456 7 8 9 10 11 12 DIGITS 1-3: PRODUCT TYPE DIGIT 8: ELECTRICAL Model Number Description CHARACTERISTICS TWE = Split System Heat Pump/ All products are identified by a Cooling Air Handler 1 = 208-230/60/1 multiple-character model number that precisely identifies a particular 3 = 208-230/60/3 DIGITS 4-6: NOMINAL GROSS type of unit. An explanation of the 4 = 460/60/3 COOLING CAPACITY (MBh) alphanumeric identification code is W = 575/60/3 060 =

Summary of the content on the page No. 5

General Information Installation procedures should be General Unit Inspection performed in the sequence that they This manual covers installation of Inspect material carefully for any appear in this manual. Do not the TWE050, 060, 075, 090,100 and shipping damage. If damaged, it destroy or remove the manual from 120A single circuit air handlers and must be reported to, and claims the unit. TWE060, 075, 090, 100, 120, 155, 180, made against the transportation 200 and 240B dual circuit

Summary of the content on the page No. 6

Unit Dimensions Unit Dimensions Figure 1. 6 TWE-SVX03C-EN

Summary of the content on the page No. 7

Unit Dimensions Figure 1. (continued from previous page) TWE-SVX03C-EN 7

Summary of the content on the page No. 8

Unit Dimensions Figure 2. 8 TWE-SVX03C-EN

Summary of the content on the page No. 9

Unit Dimensions Figure 3. TWE-SVX03C-EN 9

Summary of the content on the page No. 10

Installation Installation Preparations Process for Drain Pan Relocation The final position for the air handler 1. Remove the access plate at the must be dictated by required service opposite end of the drain access to it, weight distribution over connection. This plate secures structural supports, and by the and lifts the back end of the locations of electrical, refrigerant drain pan for sloping. It must be and condensate drainage removed before the drain pan connections. After this is can

Summary of the content on the page No. 11

Installation The crated unit can be moved using a Refrigerant Piping Preparation Caution forklift of suitable capacity. For lifting System Component Damage! The air handler is designed so that the unit into an elevated mounting Properly insulate all refrigerant gas refrigerant piping can enter from position, run lifting straps or slings piping to prevent possible water either the right or left hand side. It is under the unit and attach securely to damage due to condensation and to sh

Summary of the content on the page No. 12

Installation be installed, but should not be contains two (2) brass clamps Caution connected to the primary drain line (straps) and cork impregnated Equipment Damage! from the unit. Isolate the auxiliary insulation material approximately 9" Before hanging the unit on drain pan from both the air handler long by 4" wide. This is for attaching suspension rods, reinforce the and the structure. and insulating the expansion valve cabinet around the knockouts by bulb(s) to the suction line(s).

Summary of the content on the page No. 13

Installation Note: Important! When air handler filter track to increase the width of the  WARNING is installed in the vertical filter opening. Hazardous Voltage position and close proximity w/Capacitors! trapping of condensate is Duct Connections Disconnect all electric power, required, use of a subbase The supply and return ducts should including remote disconnects and accessory to raise the air be connected to the unit with flame discharge all motor start/run handler for clearance o

Summary of the content on the page No. 14

Installation � Inspect duct outlets. Outlets WARNING must be open and unrestricted. Hazardous Voltage! � Inspect unit drain lines. Pipe Disconnect all electric power, connections must be tight and including remote disconnects before drain line unrestricted. servicing. Follow proper lockout/ � Inspect fan assembly to insure all tagout procedures to ensure the moving parts move freely. power can not be inadvertently energized. Failure to disconnect � If unit is horizontally mounted, po

Summary of the content on the page No. 15

Field Wiring Thermostat and Control Connections 1. Observe all notes on the diagrams. 2. Mount the thermostat in the desired location. 3. Install color coded low voltage cables between outdoor unit, indoor unit and thermostat. 4. Connect low voltage control wiring to the low voltage terminal board located on the side of the fan control box per the typical interconnecting wiring diagrams on pages 13 through 22. TTA090A/TWE090A TTA120A/TWE120A Field Wiring: a. 3 power wires. Line volt

Summary of the content on the page No. 16

Field Wiring b. 3 power wires. Line voltage (2) TW_030/TWE060B for 3 phase; 2 wires for single (2) TW_060/TWE120B phase. Field Wiring: c. Heat pump thermostat: 6 a. 3 power wires. Line voltage wires, 24 volts. for 3 phase; 2 wires for single i. Electric heat: add 2 phase. additional wire, 24 volts. b. 3 power wires. Line voltage d. 2 wires, 24 volts. for 3 phase; 2 wires for single i. Outdoor thermostat; add phase. 1 additional wire, 24 volts. c. Heat pump thermostat: 7 ii. Electric

Summary of the content on the page No. 17

Field Wiring Figure 11. TTA090A, 120A/TWE090A, 120A; TTA075A, 100A/TWE075A, 100A Figure 12. TTA120B/TWE120B; TTA120C/TWE120A; TTA100B/TWE100B; TTA100C/TWE100A TWE-SVX03C-EN 17

Summary of the content on the page No. 18

Field Wiring Figure 13. TWA090A, 120A/TWE090A, 120A; TWA075A, 100A/TWE075A, 100A Figure 14. TTA120B/TWE120B; TTA120C/TWE120A; TTA100B/TWE100B; TTA100C/TWE100A 18 TWE-SVX03C-EN

Summary of the content on the page No. 19

Field Wiring Figure 15. TTA090A, 120A/TWE090A, 120A; TTA075A, 100A/TWE075A, 100A Figure 16. TW_060/TWE060; TW_050/TWE050 TWE-SVX03C-EN 19

Summary of the content on the page No. 20

Field Wiring Figure 17. TW_060/TWE060; TW_050/TWE050 Figure 18. TW_060/TWE060; TW_050/TWE050 20 TWE-SVX03C-EN


Alternative user manuals
# User manual Category Download
1 American Standard TWE060B***E User manual Heat Pump 2
2 American Standard TWE120A***F User manual Heat Pump 0
3 American Standard TWE090B***E User manual Heat Pump 0
4 American Standard TWE180B***E User manual Heat Pump 2
5 American Standard TWE060A***E User manual Heat Pump 6
6 American Standard TWE090A***E User manual Heat Pump 1
7 American Standard TWE155BD**E User manual Heat Pump 0
8 American Standard TWE100BD**E User manual Heat Pump 0
9 American Standard TWE240B***F User manual Heat Pump 1
10 American Standard Split System Cooling orAir Handler User manual Heat Pump 1
11 American Standard TWE050AD**E User manual Heat Pump 1
12 American Standard TWE075AD**E User manual Heat Pump 0
13 American Standard TWE120B***E User manual Heat Pump 2
14 American Standard TWE200BD**F User manual Heat Pump 0
15 Edelbrock 15005 User manual Heat Pump 0
16 A.O. Smith AH User manual Heat Pump 2
17 ACS 882.00217.00 User manual Heat Pump 1
18 A.O. Smith AHD 290 User manual Heat Pump 3
19 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5