Summary of the content on the page No. 1
Split System
Heat Pump
Product Data
XB14 4TWB4
1
1 /2 - 5 Tons
PUB. NO. 22-1834-09
Summary of the content on the page No. 2
Features and Benefits • CLIMATUFF® compressor • Liquid line filter/dr ier • Efficiency up to 16.0 SEER and • P olyslate g r a y cabinet with 8.5 HSPF anthr acite g r a y badge • All alumin um SPINE FIN ™ coil • High pressure s witch • WEATHERGUARD ™ f asteners • Demand Defrost with Diagnostics • QUICK-SESS ™ cabinet, • R-410A refr iger ant ser vice access and refr iger ant • S .E.E.T . design testing connections with full coil • 100% line r un test protection • Lo w
Summary of the content on the page No. 3
Contents Features and Benefits 2 General Data 4 Product Specifications 4 A-w eighted Sound P o w er Le v el [dB(A)] 4 Accessor y Descr iption and Usage 6 AHRI Standard Capacity Rating Conditions 6 Model Nomenclature 7 Electrical Data 8 Dimensions 15 Mechanical Specification Options 16 22-1834-09 3
Summary of the content on the page No. 4
General Data Product Specifications Model No. 1 4TWB4018G1 4TWB4024G1 4TWB4030G1 4TWB4036G1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 9 11 15 18 Max Fuse Size (Amps) 15 15 25 30 ® ® ® ® Compressors CLIMATUFF CLIMATUFF CLIMATUFF CLIMATUFF RL AMPS - LR AMPS 6.4 - 38.6 8.3 - 58 11.3 - 68.2 13.2 - 63 Outdoor Fan FL Amps 0.70 0.74 0.92 1.00 Fan HP 1/8 1/8 1/5 1/5 Fan Dia (inches) 23 23 27.5 27.5 Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Ref
Summary of the content on the page No. 5
General Data Product Specifications Model No. 1 4TWB4042E1 4TWB4048E1 4TWB4049E1 4TWB4060E1 4TWB4061E1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 27 29 28 35 36 Max Fuse Size (Amps) 45 50 50 60 60 ® - ® - ® - ® - ® - Compressors CLIMATUFF SCROLL CLIMATUFFSCROLL CLIMATUFFSCROL CLIMATUFF SCROLL CLIMATUFF SCROL RL AMPS - LR AMPS 19.9 - 109 21.8 - 117 21.8 - 117 26.4 - 134 26.4 - 134 Outdoor Fan FL Amps 0.93 0.93 1.00 0.93 2
Summary of the content on the page No. 6
General Data Accessory Description and Usage AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS — Anti-Short Cycle Timer — Solid state timing de vice that (A) Cooling 80°F DB , 67°F WB air enter ing indoor coil, pre v ents compressor recycling until 5 min utes ha v e elapsed 95°F DB air enter ing outdoor coil. after satisfying call or po w er interr uptions . Use in area with questionab le po w er deliv er y , commercial applications , long AHRI STANDARD 2
Summary of the content on the page No. 7
Model Nomenclature TU D2 B0 80 AC V3 2 AA 4T WB 40 36 G1 000 AA Gas Furnaces Outdoor Units Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-23
Summary of the content on the page No. 8
Electrical Data Schematic Diagrams 4TWB4018, 4TWB4024, 4TWB4036 Pr inted from D156770P01 Re v 00 8 22-1834-09
Summary of the content on the page No. 9
Electrical Data Schematic Diagrams 4TWB4030 Pr inted from D157099P01 22-1834-09 9
Summary of the content on the page No. 10
Electrical Data Schematic Diagrams 4TWB4042 TDR rela y cycles sump heat off dur- ing compressor oper ation and dela ys energizing the sump heat f or 30 mins after “Y” call is remo v ed. Pr inted from D156131P02 Re v 00 10 22-1834-09
Summary of the content on the page No. 11
Electrical Data Schematic Diagrams 4TWB4048 TDR rela y cycles sump heat off dur- ing compressor oper ation and dela ys energizing the sump heat f or 30 mins after “Y” call is remo v ed. Pr inted from D156128P02 Re v 00 22-1834-09 11
Summary of the content on the page No. 12
Electrical Data Schematic Diagrams (SEE LEGEND) 4TWB4049E TDR rela y cycles sump heat off dur- ing compressor oper ation and dela ys energizing the sump heat f or 30 mins after “Y” call is remo v ed. PRINTED FROM D156976P01 REV. 00 12 22-1834-09
Summary of the content on the page No. 13
Electrical Data Schematic Diagrams 4TWB4060 TDR rela y cycles sump heat off dur- ing compressor oper ation and dela ys energizing the sump heat f or 30 mins after “Y” call is remo v ed. Pr inted from D156129P02 Re v 00 22-1834-09 13
Summary of the content on the page No. 14
Electrical Data Schematic Diagrams (SEE LEGEND) 4TWB4061E TDR rela y cycles sump heat off dur- ing compressor oper ation and dela ys energizing the sump heat f or 30 mins after “Y” call is remo v ed. PRINTED FROM D154974P02 REV. 00 14 22-1834-09
Summary of the content on the page No. 15
Dimensions 4TWB4 Outline Drawing Note: All dimensions are in MM (Inches). MODELS BASE A B C D E F G H J K 4TWB4018G 4 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 4TWB4024G 3 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 4TWB4030G 4 841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 4TWB4036G 4 841 (33-1/8) 946 (37-1/4) 870
Summary of the content on the page No. 16
Mechanical Specification Options General Condenser Coil The 4TWB4 is fully charged from the The outdoor coil pro vides lo w airflo w f actor y f or up to 15 f eet of piping. This resistance and efficient heat tr ansf er . unit is designed to oper ate at outdoor The coil is protected on all f our sides b y ambient temper atures as high as 115°F . louv ered panels . Cooling capacities are matched with Low Ambient Cooling a wide selection of air handlers and As man uf actured, this