Trane 060E user manual

User manual for the device Trane 060E

Device: Trane 060E
Category: Heat Pump
Manufacturer: Trane
Size: 1.55 MB
Added : 1/22/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane 060E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane 060E.

For your convenience

If looking through the Trane 060E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane 060E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane 060E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane 060E User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane 060E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane 060E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Split System
Heat Pump
Product Data
XL16i
4TWX6024, 036, 048 & 060E
2, 3, 4 & 5 Tons
PUB. NO. 22-1754-17

Summary of the content on the page No. 2

Features and Benefits • CLIMATUFF™ 2-stage scroll • Internal compressor high/low compressor pressure & temperature protection • Efficiency up to 18.0 SEER and • Liquid line filter/drier 9.0 HSPF • Low sound with advanced variable • All Aluminum SPINE FIN™ coil speed fan motor • WEATHERGUARD™ II top shields • Service valve cover unit • R-410A refrigerant • DURATUFF™ weather proof and • From 70 to 100% capacity rust proof base modulation • COMFORT ”R”™ mode approved • 100% run test in th

Summary of the content on the page No. 3

Contents Features and Benefits 2 General Data 4 Product Specifications 4 A-weighted Sound Power Level [dB(A)] 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 10 Mec hanical Specifications 11 22-1754-17 3

Summary of the content on the page No. 4

General Data Product Specifications Model No. 1 4TWX6024E1 4TWX6036E1 4TWX6048E1 4TWX6060E1 Electrical Data V/Ph/Hz 2 230/1/60 230/1/60 230/1/60 230/1/60 Min Cir Ampacity 14 22 28 39 Max Fuse Size (Amps) 20 35 45 60 ® ® ® ® Compressor CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL AMPS - LR AMPS 10.3 - 52 16.7 - 82 21.2 - 104 28.8 - 152.9 Outdoor Fan FL Amps 0.74 0.74 1.00 2.80 Fan HP 1/8 1/8 1/5 1/3 Fan Dia (inches) 27.6 27.6 27.6 27.6 Coil Spine Fin™ Spine Fin

Summary of the content on the page No. 5

General Data AHRI Standard Capacity Rating Conditions Accessory Description and Usage AHRI STANDARD 210/240 RATING CONDITIONS — Rubber Isolators — 5 rubber donuts to isolate condens- (A) Cooling 80°F DB, 67°F WB air entering indoor coil, ing unit from mounting frame or pad. Use on any application 95°F DB air entering outdoor coil. where sound transmission needs to be minimized. (B) High Temperature Heating 47°F DB, 43°F WB air entering Extreme Conditions Mounting Kit — Bracket kits to secure

Summary of the content on the page No. 6

Model Nomenclature TU D2 B0 80 AC V3 2 AA Gas Furnaces 4T WX 60 36 E1 000 AA Outdoor Units Refrigerant Type 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial Family SEER 3 = 13 6 = 16 0 = 20 4 = 14 8 = 18 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-23

Summary of the content on the page No. 7

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6024 Printed from D156993P02 22-1754-17 7

Summary of the content on the page No. 8

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6036E Printed from D156631P06 Rev 00 8 22-1754-17

Summary of the content on the page No. 9

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6048E 12 5 Printed from D156977 22-1754-17 9

Summary of the content on the page No. 10

BK/BL Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6060E ACR -A/C RECTIFIER CBS- COIL BOTTOMSENSOR CF -FAN CAPACITOR TO POWER SUPPLY PERUNIT NAMEPLATE AND LOCAL CODES CN -WIRE CONNECTOR CPR- COMPRESSOR CR -RUN CAPACITOR SUMP HTR CS -STARTINGCAPACITOR TDL CSR -CAPACITOR SWITCHINGRELAY BK BK PR/WH PR/WH DFC- DEFROSTCONTROL EEV- ELECTRONIC EXPVALVE START KITBAYKSKT263 EEVC -ELECTRONICEXP VALVECONTROL CS F -INDOORFAN RELAY MS-1 CSR-1 CSR HPCO -HIGHPRESSURECUTOUTSWITCH MS-2 RD BR IOL -INTERNA

Summary of the content on the page No. 11

Dimensions 4TWX6 Outline Drawing Note: All dimensions are in MM (Inches). MODELS BASE A B C D E F G H J K 4TWX6024E 4 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 5/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6036E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6048E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6060E 4 1369 (53-7/8) 946 (37-1/4) 870 (3

Summary of the content on the page No. 12

Mechanical Specifications General Condenser Coil The 4TWX6 is fully charged from the The outdoor coil provides low airflow factory for matched indoor section resistance and efficient heat transfer. and up to 15 feet of piping. This unit is The coil is protected on all four sides by designed to operate at outdoor ambient louvered panels. temperatures as high as 115°F. Cooling Low Ambient Cooling capacities are matched with a wide se- As manufactured, this unit has a cool- lection of air ha


Alternative user manuals
# User manual Category Download
1 Trane 060E User manual Air Conditioner 22
2 Trane 22-5202-03-3605 User manual Heat Pump 0
3 Trane 2TWB0-UM-2 User manual Heat Pump 0
4 Trane 4TWX6 User manual Heat Pump 1
5 Trane 2TWB-SVU01A-EN User manual Heat Pump 1
6 Trane 4TWX6036B User manual Heat Pump 2
7 Trane 4TWX6048B User manual Heat Pump 1
8 Trane 4TWX606OB User manual Heat Pump 0
9 Trane 4TWX6024B User manual Heat Pump 0
10 Trane 4YCY4024A User manual Heat Pump 5
11 Trane 4YCY4060A User manual Heat Pump 0
12 Trane EXWA User manual Heat Pump 7
13 Trane GETB User manual Heat Pump 2
14 Trane GEH User manual Heat Pump 27
15 Trane GEV User manual Heat Pump 3
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5