Trane PKGP-PRC001-EN user manual

User manual for the device Trane PKGP-PRC001-EN

Device: Trane PKGP-PRC001-EN
Category: Heat Pump
Manufacturer: Trane
Size: 1.82 MB
Added : 1/22/2014
Number of pages: 52
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane PKGP-PRC001-EN. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane PKGP-PRC001-EN.

For your convenience

If looking through the Trane PKGP-PRC001-EN user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane PKGP-PRC001-EN on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane PKGP-PRC001-EN to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane PKGP-PRC001-EN User manual - Online PDF
Advertisement
« Page 1 of 52 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane PKGP-PRC001-EN but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane PKGP-PRC001-EN. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Packaged Heat Pumps
Voyager™
12½ to 20 Tons — 60 Hz
PKGP-PRC001-EN
September 2004

Summary of the content on the page No. 2

Introduction Packaged Rooftop Air Conditioners Through the years, Trane has designed Trane customers demand products that and developed the most complete line of provide exceptional reliability, meet Packaged Rooftop products available in stringent performance requirements, and the market today. Trane was the first to are competitively priced. Trane delivers introduce the Micro—microelectronic with Voyager. unit controls—and has continued to Voyager features cutting edge improve and revolutiona

Summary of the content on the page No. 3

Contents 2 Introduction Features and Benefits 4 Application Considerations 9 Selection Procedure 10 Model Number Description 11 General Data 12 Performance Data 14 Cooling Performance 14 Fan Performance 17 Heating Performance 22 Controls 26 Electric Power 27 Dimension and Weights 38 Mechanical Specifications 48 PKGP-PRC001-EN 3

Summary of the content on the page No. 4

Features and Benefits Factory Installed Options Field Installed Options  Black Epoxy Pre-Coated Coils  CO Sensing 2  High Efficiency Motors  Digital Display Zone Sensor  High Pressure Cutout  Dual Thermistor Remote Zone Sensor  Hinged Access Doors  High Static Drive  Powered or Unpowered Convenience  Manual Outside Air Damper Outlet  Motorized Outside Air Dampers  Supply and/or Return Air Smoke  Powered Exhaust Detector  Downflow – Roof Curb  Through the Base Electrical with Circu

Summary of the content on the page No. 5

Features and Benefits Quality and Reliability are enhanced ReliaTel Makes Testing Easy Easy to Install, Service and through ReliaTel control and logic: ReliaTel requires no special tools to run Maintain the Voyager unit through its paces. —prevents the unit from short cycling, Because today’s owners are very cost- Simply place a jumper between Test 1 considerably improving conscious when it comes to service and and Test 2 terminals on the Low Voltage compressor life. maintenance, the Trane Voyag

Summary of the content on the page No. 6

Features and Benefits Condenser Coil High Static Drive Accessory Outstanding Standard and Voyager boasts a patent-pending 1+1+1 Available on many models, this high Optional Components condenser coil, permanently gapped for static drive accessory extends the easy cleaning. capability of the standard motor. Avoid Black Epoxy Pre-Coated Coils expensive motors and operating costs by The pre-coated coils are an economical installing this optimized sheave option for protection in mildly corrosive acce

Summary of the content on the page No. 7

Features and Benefits Reference or Comparative Enthalpy VariTrac Actual shipping tests were performed to Measures and communicates humidity When T rane’ s changeover VA V System determine packaging requirements. Units while maximizing comfort control. for light commercial applications is were test shipped around the country to coupled with Voyager, it provides the determine the best packaging. Factory Sloped Drain Pans latest in technological advances for shake and drop tests were used as part S

Summary of the content on the page No. 8

Features and Benefits Powered or Unpowered Convenience Factory Installed Options Easy to Install and Service Outlet A wide variety of Factory Installed Conversionless Units This option is a GFCI, 120v/15amp, 2 plug, Options (FIOPs) are available. The dedicated design units (either convenience outlet, either powered or downflow or horizontal) require no panel Added Efficiency unpowered. This option can only be removal or alteration time to convert in ordered when the Through the Base Airflow the

Summary of the content on the page No. 9

Application Considerations Application of this product should be Power Exhaust Accessory within the cataloged airflow and cooling The power exhaust accessory is considerations. available on all downflow units. This accessory can be field installed and will Low Ambient Cooling assist in relieving building pressurization. This Voyager line features, as standard, low ambient cooling down to 0°F . Contact Condensate T rap your local Trane Representative for more The evaporator is a draw-thru assist

Summary of the content on the page No. 10

Selection Procedures To Find Capacity at Intermediate Cooling Capacity Heating Capacity Conditions Step 1 Step 1 When the design conditions are between Calculate the building heating load using Calculate the building’s total and sensible two numbers that are in the capacity the Trane calculation form or other cooling loads at design conditions. Use table, interpolation is required to standard accepted method. the Tranecalculation form or any other approximate the capacity. standard accepted meth

Summary of the content on the page No. 11

Model Number Description Packaged Heat Pump Unit Model Nomenclature W C D 150 C 3 0 0 B A 12 3 456 7 8 9 10 11 12 Digits 1,2 Product Type Digits 9, 10 - Factory Installed Options WC = Heat Pump, Packaged WF = With Factory Installed Options 00 = Packed Stock, No Options 0A= Factory Installed Downflow Economizer Digit 3 - Airflow Configuration 0B = Oversize Motor D = Downflow 0C = Downflow Economizer and Oversize H = Horizontal Motor 0F = Trane Communications Interface (TCI) 0G =Downflow Economi

Summary of the content on the page No. 12

General Data (12½ T on) Table GD-1 — General Data 12½ Ton Downflow and Horizontal Units WCD150B3, B4, BW WCH150B3, B4, BW 1 Cooling Performance Gross Cooling Capacity 152,00 152,000 2 EER 9.5 9.5 Nominal CFM / ARI Rated CFM 4,400 / 4,400 4,400 / 4,400 ARI Net Cooling Capacity 144,000 144,000 3 Integrated Part Load Value 9.9 9.9 System Power KW 15.16 15.16 1 Heating Performance High Temp. Btuh Rating 135,000 132,000 System Power KW/COP 12.76/3.10 12.48/3.10 Low Temp. Btuh Rating 78,000 72,000 Sys

Summary of the content on the page No. 13

General Data (15, 20 Ton) Table GD-2 — General Data 15 Ton Downflow and Horizontal Units 20 Ton Downflow and Horizontal Units WC*180B3, B4, BW WCD240B3, B4, BW WCH240B3, B4, BW 1 Cooling Performance Gross Cooling Capacity 180,000 233,000 237,000 2 EER 9.6 9.8 10.5 Nominal CFM / ARI Rated CFM 6,000 / 5,300 8,000 / 8,000 8,000/7,000 ARI Net Cooling Capacity 168,000 222,000 224,000 3 Integrated Part Load Value 10.0 9.7 10.3 System Power KW 17.50 22.2 21.3 1 Heating Performance High Temp. Btuh Rati

Summary of the content on the page No. 14

Performance Data (12½ T on) Table PD-1 — Gross Cooling Capacities (MBh) 12½ Ton Downflow Three Phase WCD150B Ambient T emperature (F) 85 95 105 115 Enter. Dry Entering Wet Bulb (F) CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73 Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 75 140.0 113.0 153.0 90.8 158.0 57.9 128.0 106.0 149.0 83.3 160.0 56.3 116.0 99.8 137.0 83.3 157.0 53.5 104.0 93.3 124.0 77.1 148.0 48.9 4500 80 141.0 134.0 154.0 105

Summary of the content on the page No. 15

Performance Data (15 Ton) Table PD-3 — Gross Cooling Capacities (MBh) 15 Ton Downflow and Horizontal Three Phase WC*180B Ambient Temperature ( F) 85 95 105 115 Enter. CFM Dry Entering Wet Bulb (F) Bulb 61 67 73 61 67 73 61 67 73 61 67 73 Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 75 162.3 130.3 184.5 103.3 194.1 71.1 150.5 124.1 176.5 99.0 190.3 68.4 137.5 117.3 163.6 93.0 185.5 65.5 124.8 110.8 149.4 94.8 176.1 61.2 80 163.8 154.

Summary of the content on the page No. 16

Performance Data (20 T on) Table PD-4 — Gross Cooling Capacities (MBh) 20 Ton Downflow Three Phase WCD240B Ambient T emperature (F) 85 95 105 115 Enter. CFM Dry Entering Wet Bulb (F) Bulb 61 67 73 61 67 73 61 67 73 61 67 73 Airflow (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 75 212.0 177.0 233.0 137.0 243.0 89.7 198.0 173.0 228.0 133.0 244.0 87.3 179.0 164.0 211.0 130.0 239.0 83.1 160.0 154.0 189.0 115.0 225.0 76.8 80 219.0 218.0 234.0 165.

Summary of the content on the page No. 17

Performance Data (12½ T on) Table PD-6 — Evaporator Fan Performance — 12½ Ton — WC*150B External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3 HP Standard Motor & Field Supplied Low Static Drive (1) 3 HP Standard Motor & Drive 4000 — — 506 0.69 537 0.80 568 0.92 599 1.03 631 1.15 662 1.26 694 1.37 726 1.48 756 1.59 4500 511 0.87 541 0.98 572 1.09 603 1.21 634 1.32 664 1.43 693 1.55

Summary of the content on the page No. 18

Performance Data (15 Ton) Table PD-7 — Evaporator Fan Performance — 15 Ton — WCD180B External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3 HP Standard Motor Drive 4800 691 1.64 723 1.81 751 1.97 778 2.13 808 2.32 836 2.51 861 2.68 885 2.86 909 3.04 931 3.22 5400 769 2.29 799 2.48 826 2.66 850 2.83 874 3.02 900 3.23 926 3.45 950 3.65 972 3.86 993 4.05 6000 848 3.09 875 3.30 901 3.51

Summary of the content on the page No. 19

Performance Data (20 T on) Table PD-9 — Evaporator Fan Performance — 20 Ton — WC*240B External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5 HP Standard Motor & Field Supplied Low Static Drive (1) 5 HP Standard Motor & Drive 6400 — — 531 1.80 556 1.97 582 2.14 610 2.28 634 2.44 658 2.61 681 2.79 705 2.98 729 3.19 7200 552 2.23 576 2.16 605 2.60 631 2.81 655 3.00 678 3.18 701 3.36 72

Summary of the content on the page No. 20

Performance Data (12½ - 20 Tons) Table PD-10 — Standard Motor & Drive/Fan Speed (RPM) Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Tons Model No. Open Open Open Open Open Open Closed 12½ WC*150B 640 680 720 760 800 840 N/A 15 WC*180B 679 721 764 806 849 891 N/A 20 WC*240B 615 659 703 747 791 835 N/A Factory set at 3 turns open. Table PD-11 — Standard Motor With High Static Drive Fan Speed (RPM) Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Tons Model No. Open Open Open Open Open Ope


Alternative user manuals
# User manual Category Download
1 Trane 22-5202-03-3605 User manual Heat Pump 0
2 Trane 2TWB0-UM-2 User manual Heat Pump 0
3 Trane 4TWX6 User manual Heat Pump 1
4 Trane 2TWB-SVU01A-EN User manual Heat Pump 1
5 Trane 4TWX6036B User manual Heat Pump 2
6 Trane 4TWX6048B User manual Heat Pump 1
7 Trane 4TWX606OB User manual Heat Pump 0
8 Trane 4TWX6024B User manual Heat Pump 0
9 Trane 4YCY4024A User manual Heat Pump 5
10 Trane 4YCY4060A User manual Heat Pump 0
11 Trane EXWA User manual Heat Pump 7
12 Trane GETB User manual Heat Pump 2
13 Trane GEH User manual Heat Pump 27
14 Trane GEV User manual Heat Pump 3
15 Trane GSWD User manual Heat Pump 0
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5