Trane GEH user manual

User manual for the device Trane GEH

Device: Trane GEH
Category: Heat Pump
Manufacturer: Trane
Size: 5.27 MB
Added : 1/22/2014
Number of pages: 90
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane GEH. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane GEH.

For your convenience

If looking through the Trane GEH user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane GEH on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane GEH to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane GEH User manual - Online PDF
Advertisement
« Page 1 of 90 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane GEH but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane GEH. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation
Owner
Diagnostics
TM
Axiom Horizontal/Vertical
Water-Source Comfort System
Models GEH and GEV
15 - 25 Ton
1/2 - 5 Ton
6 - 10 Ton
6 - 15 Ton
Models
“A” and later Design Sequence
GEH GEV
006 - 060 – 60 HZ 006 - 060 – 60 HZ
006 - 060 – 50 HZ 006 - 060 – 50 HZ
072 - 180 – 60 HZ 072 - 300 – 60 HZ
072 - 150 – 50 HZ 072 - 240 – 50 HZ
WSHP-SVX01D-EN

Summary of the content on the page No. 2

Notice NOTICE: Warnings and Cautions appear at appropriate sections throughout this manual. Read these carefully. WARNING -Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION -Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. CAUTION -Indicates a situation that may result in equipment or property-damage-only accidents.

Summary of the content on the page No. 3

Contents Installation/Startup/Commissioning 4 Pre-installation Checklist 4 5 General Information 7 Dimensions/Weights 48 Installation Instructions 67 Electrical Requirements Pre-Startup Checklist 73 74 Startup/Commissioning 74 Sequence of Operation 81 Startup Checklist & Log 82 Maintenance 83 Warranty Information 84 Troubleshooting Checklist 86 Unit Wiring WSHP-SVX01D-EN 3

Summary of the content on the page No. 4

Pre-installation Checklist WARNING Fiberglass Wool! Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance or repair will expose you to airborne particles of glass wool fibers and ceramic fibers known to the state of California to cause cancer through inhalation. Glass wool fibers may also cause respiratory, skin or eye irritation. Jobsite Inspection Always perform the following checks before accepting a unit: 1. Verify that the nameplat

Summary of the content on the page No. 5

General Information Unit Nameplate pabilities depends upon the type of compressor disable, condensate over- The unit nameplate is located on the sensor and/or remote panel selected. flow, unit safety control, diagnostics outside of the control box access panel Troubleshooting and connection dia- and a generic relay (which may be at the front of the unit. It includes the grams for the 24 Volt control systems available for field use). See page 56 for unit model number, serial number, may be loc

Summary of the content on the page No. 6

General Information (option) Boilerless Control/Electric (option) Hot Gas Reheat Heat With the reheat option, the return-air Systems that do not contain a boiler from the space is conditioned by the may contain a boilerless control with air-to-refrigerant coil, then reheated electric heat. Trane offers both a facto- by the reheat coil to control not only ry mounted electric heat option, and a the space temperature, but to also re- field mounted duct heater option. duce the relative humidity

Summary of the content on the page No. 7

Dimensions/Weights Table 1: Unit weights GEH GEH GEV GEV Shipping Weight Shipping Weight 60 HZ 50 HZ 60 HZ 50 HZ with pallet w/o pallet 006-015 006-012 188 lb (85 kg) 158 lb (71 kg) WARNING 018-030 015-024 278 lb (125 kg) 248 lb (112 kg) Improper Unit Lift! 036-042 030-036 318 lb (143 kg) 288 lb (130 kg) Test lift unit approximately 24 inches 048-060 042-060 428 lb (193 kg) 398 lb (179 kg) to verify proper center of gravity lift 072 - 701 lb (318 kg) 652 lb (296 kg) point. To avoid dropping of

Summary of the content on the page No. 8

Dimensions/Weights Clearance GEH Clearance Dimensions Access to the unit for service pur- poses should be provided at instal- lation. All 1/2 through 5 ton configurations require an 18" (457 mm) surround clearance from oth- er mechanical and electrical equip- ment (where shown) to enable panel removal from the unit for service/maintenance ability. Some local codes require a greater ser- vice clearance than listed below. Check all code requirements prior to unit installations. Equipment co

Summary of the content on the page No. 9

Dimensions/Weights Clearance GEV 1/2 through 5 Ton Clearance Dimensions (Figure 1) Access to the unit for service purposes should be provided at installation. All configurations require an 24" (610 mm) surround clearance from other me- chanical and electrical equipment (where shown) to enable panel remov- al from the unit for service/mainte- nance ability. Some local codes require a greater service clearance than listed below. Check all code requirements prior to unit installations. Unit

Summary of the content on the page No. 10

Dimensions/Weights Left Return/Left Supply L M Unit A B C D E F G H J K NP Q R S NPTI NPTI 40" 20" 15" 20" 15" 6 7/8" 8" 11 1/2" 4 1/4" 2 1/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 006,009 (1016) (508) (381) (508) (381) (175) (203) (292) (108) (54) (12.7) (12.7) (984) (476) (346) (470) (86) 40" 20" 15" 20" 15" 6 7/8" 9 7/8" 11 1/2" 4 1/4" 2 5/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 012, 015 (1016) (508) (381) (508) (381) (175) (251) (292) (108) (67) (12.7) (12.7) (984) (47

Summary of the content on the page No. 11

Dimensions/Weights Left Return/Back Supply L M Unit A B C D E F G H J K NP Q R S NPTI NPTI 40" 20" 15" 20" 15" 6 7/8" 8" 11 1/2" 4 1/4" 2 1/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 006,009 (1016) (508) (381) (508) (381) (175) (203) (292) (108) (54) (12.7) (12.7) (984) (476) (346) (470) (86) 40" 20" 15" 20" 15" 6 7/8" 9 7/8" 11 1/2" 4 1/4" 2 5/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 012, 015 (1016) (508) (381) (508) (381) (175) (251) (292) (108) (67) (12.7) (12.7) (984) (47

Summary of the content on the page No. 12

Dimensions/Weights Left Return/Right Supply Unit Unit L M AB C D E F G H J K NP Q R 60 HZ 50 HZ NPTI NPTI 40" 20" 15" 20" 15" 6 7/8" 8" 11 1/2" 4 1/4" 2 1/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 006-009 006 (1016) (508) (381) (508) (381) (175) (203) (292) (108) (54) (12.7) (12.7) (984) (476) (346) (470) 40" 20" 15" 20" 15" 6 7/8" 9 7/8" 11 1/2" 4 1/4" 2 5/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 012-015 009-012 (1016) (508) (381) (508) (381) (175) (251) (292) (108) (67) (12.7) (12.7) (9

Summary of the content on the page No. 13

Dimensions/Weights Right Return/Left Supply L M Unit A B C D E F G H J K NP Q R S NPTI NPTI 40" 20" 15" 20" 15" 6 7/8" 8" 11 1/2" 4 1/4" 2 1/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 006,009 (1016) (508) (381) (508) (381) (175) (203) (292) (108) (54) (12.7) (12.7) (984) (476) (346) (470) (86) 40" 20" 15" 20" 15" 6 7/8" 9 7/8" 11 1/2" 4 1/4" 2 5/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 012, 015 (1016) (508) (381) (508) (381) (175) (251) (292) (108) (67) (12.7) (12.7) (984) (4

Summary of the content on the page No. 14

Dimensions/Weights Right Return/Back Supply L M Unit A B C D E F G H J K NP Q R S NPTI NPTI 40" 20" 15" 20" 15" 6 7/8" 8" 11 1/2" 4 1/4" 2 1/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 006,009 (1016) (508) (381) (508) (381) (175) (203) (292) (108) (54) (12.7) (12.7) (984) (476) (346) (470) (86) 40" 20" 15" 20" 15" 6 7/8" 9 7/8" 11 1/2" 4 1/4" 2 5/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 012, 015 (1016) (508) (381) (508) (381) (175) (251) (292) (108) (67) (12.7) (12.7) (984) (4

Summary of the content on the page No. 15

Dimensions/Weights Right Return/Right Supply L M Unit A B C D E F G H J K NP Q R S NPTI NPTI 40" 20" 15" 20" 15" 6 7/8" 8" 11 1/2" 4 1/4" 2 1/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 006,009 (1016) (508) (381) (508) (381) (175) (203) (292) (108) (54) (12.7) (12.7) (984) (476) (346) (470) (86) 40" 20" 15" 20" 15" 6 7/8" 9 7/8" 11 1/2" 4 1/4" 2 5/8" 1/2" 1/2" 38 3/4" 18 3/4" 13 5/8" 18 1/2" 3 3/8" 012, 015 (1016) (508) (381) (508) (381) (175) (251) (292) (108) (67) (12.7) (12.7) (984) (

Summary of the content on the page No. 16

Dimensions/Weights Left Return/Top Supply Unit W.I. W.O. Drain AB C D E F G H J K L M N GEV NPTI NPTI FPT 19 1/2" 31 1/4" 21 1/2" 11 1/2" 4" 3 3/4" 16 1/2" 15" 18" 6 7/8" 8" 3/4" 2" 1/2" 1/2" 3/4" 006-015 (495) (794) (546) (292) (102) (95) (419) (381) (457) (175) (203) (19) (51) (12.7) (12.7) (19) 9 3/4" 018, 024, 21 1/2" 39 1/4" 21 1/2" 13 1/2" 4" 4" 17 1/2" 23 3/4" 17" 8 1/4" (248) 3/4" 2" 3/4" 3/4" 3/4" 030, 040 (546) (997) (546) (343) (102) (1021) (445) (603) (432) (368) (19) (51) (19) (19)

Summary of the content on the page No. 17

Dimensions/Weights Left Return/Back Supply Unit W.I. W.O. Drain AB C D E F G H J K L M N GEV NPTI NPTI FPT 19 1/2" 31 1/4" 21 1/2" 11 1/2" 4" 3 3/4" 16 1/2" 15" 18" 6 7/8" 8" 3/4" 2" 1/2" 1/2" 3/4" 006-015 (495) (794) (546) (292) (102) (95) (419) (381) (457) (175) (203) (19) (51) (12.7) (12.7) (19) 9 3/4" 018, 024, 21 1/2" 39 1/4" 21 1/2" 13 1/2" 4" 4" 17 1/2" 23 3/4" 17" 8 1/4" (248) 3/4" 2" 3/4" 3/4" 3/4" 030, 040 (546) (997) (546) (343) (102) (1021) (445) (603) (432) (368) (19) (51) (19) (19)

Summary of the content on the page No. 18

Dimensions/Weights Right Return/Top Supply Unit W.I. W.O. Drain AB C D E F G H J K L M N GEV NPTI NPTI FPT 19 1/2" 31 1/4" 21 1/2" 11 1/2" 4" 3 3/4" 16 1/2" 15" 18" 6 7/8" 8" 3/4" 2" 1/2" 1/2" 3/4" 006-015 (495) (794) (546) (292) (102) (95) (419) (381) (457) (175) (203) (19) (51) (12.7) (12.7) (19) 9 3/4" 018, 024, 21 1/2" 39 1/4" 21 1/2" 13 1/2" 4" 4" 17 1/2" 23 3/4" 17" 8 1/4" (248) 3/4" 2" 3/4" 3/4" 3/4" 030, 040 (546) (997) (546) (343) (102) (1021) (445) (603) (432) (368) (19) (51) (19) (19)

Summary of the content on the page No. 19

Dimensions/Weights Right Return/Back Supply Unit W.I. W.O. Drain AB C D E F G H J K L M N GEV NPTI NPTI FPT 19 1/2" 31 1/4" 21 1/2" 11 1/2" 4" 3 3/4" 16 1/2" 15" 18" 6 7/8" 8" 3/4" 2" 1/2" 1/2" 3/4" 006-015 (495) (794) (546) (292) (102) (95) (419) (381) (457) (175) (203) (19) (51) (12.7) (12.7) (19) 9 3/4" 018, 024, 21 1/2" 39 1/4" 21 1/2" 13 1/2" 4" 4" 17 1/2" 23 3/4" 17" 8 1/4" (248) 3/4" 2" 3/4" 3/4" 3/4" 030, 040 (546) (997) (546) (343) (102) (1021) (445) (603) (432) (368) (19) (51) (19) (19

Summary of the content on the page No. 20

Dimensional Data GEH-Right Return/Left Supply GEH 072-120 (60 Hz) GEH 072-090 (50 Hz) GEH GEH AB C D 60 Hz 50 Hz 36 1/4" 15 5/8" 6 5/8" 1 1/4" 072 - (921) (397) (168) (32) 36 1/8" 12 3/4" 6 3/4" 1 1/4" 090 072 (917) (324) (171) (32) 36 1/8" 13" 7 1/4" 1 1/2" 120 090 (917) (330) (184) (38) 20 WSHP-SVX01D-EN


Alternative user manuals
# User manual Category Download
1 Trane 22-5202-03-3605 User manual Heat Pump 0
2 Trane 2TWB0-UM-2 User manual Heat Pump 0
3 Trane 4TWX6 User manual Heat Pump 1
4 Trane 2TWB-SVU01A-EN User manual Heat Pump 1
5 Trane 4TWX6036B User manual Heat Pump 2
6 Trane 4TWX6048B User manual Heat Pump 1
7 Trane 4TWX606OB User manual Heat Pump 0
8 Trane 4TWX6024B User manual Heat Pump 0
9 Trane 4YCY4024A User manual Heat Pump 5
10 Trane 4YCY4060A User manual Heat Pump 0
11 Trane EXWA User manual Heat Pump 7
12 Trane GETB User manual Heat Pump 2
13 Trane GEV User manual Heat Pump 3
14 Trane GSWD User manual Heat Pump 0
15 Trane PKGP-PRC003-EN User manual Heat Pump 1
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5