Trane 4YCY4060A user manual

User manual for the device Trane 4YCY4060A

Device: Trane 4YCY4060A
Category: Heat Pump
Manufacturer: Trane
Size: 3.08 MB
Added : 9/18/2014
Number of pages: 29
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane 4YCY4060A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane 4YCY4060A.

For your convenience

If looking through the Trane 4YCY4060A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane 4YCY4060A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane 4YCY4060A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane 4YCY4060A User manual - Online PDF
Advertisement
« Page 1 of 29 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane 4YCY4060A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane 4YCY4060A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

22-1797-03
Product Data
4YCY4024A through 4YCY4060A
Single Packaged Convertible Gas/Electric
14 SEER
2 - 5 Ton, 40 - 120 KBTU
R-410A
© 2008 Trane Pub. No. 22-1797-03

Summary of the content on the page No. 2

      Single Packaged Convertible Gas/Electric System Trane offers a complete family of packaged gas/electric heating and cooling sys- tems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the packaged gas/electric system functions as an all-electric, high efficiency air conditioner. In cold weather, it operates as a natural gas or propane gas furnace, offering you the best of both energy worlds. Introducing th

Summary of the content on the page No. 3

Contents Optional Equipment Listing 4 General Data 5 Performance Data Cooling 9 Indoor Fan 11 Typical Wiring 15 Optional Equipment 18 Dimensional Data 23 Mechanical Specifications 29 3

Summary of the content on the page No. 4

Optional Equipment Listing OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [✓✓✓✓✓] indicates accessories included) Hinged Filter Access Door (4YCY4024-036) 8 ................................................................ BAYACCDOR1A[ ] Hinged Filter Access Door (4YCY4042-060) 8 ................................................................ BAYACCDOR2A[ ] Roof Curb Full Perimeter (4YCY4024-36A) 3 ................................................................... BAYCURB050A[ ] Roof C

Summary of the content on the page No. 5

General Data 4YCY4030A1075A 4YCY4036A1075A 4YCY4036A1096A MODEL 4YCY4024A1064A RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 30000 36000 36000 Performance Cooling BTUH 23400 Indoor Airflow (CFM) 790 900 1210 1210 2.5 3.284 Power Input (KW) 2.162 3.284 EER/SEER(BTU/Watt-Hr.) 11.6 / 14.0 12.0 / 14.0 11.6 / 14.2 11.6 / 14.2 71 69 69 Sound Power Rating [dB(A)]8 68 Performance Heating 56250 56250 72000 Input BTUH - 1st Stage (Natural Gas) 48000 Input BTUH - 2nd Stage (Natu

Summary of the content on the page No. 6

General Data MODEL 4YCY4036A3075A 4YCY4036A3096A 4YCY4042A1096A RATED Volts/PH/Hz 208-230/3/60 208-230/3/60 208-230/1/60 Performance Cooling BTUH 36000 36000 42000 Indoor Airflow (CFM) 1210 1210 1350 Power Input (KW) 3.284 3.284 3.5 EER/SEER(BTU/Watt-Hr.) 11.6 / 14.2 11.6 / 14.2 12.0 / 14.25 Sound Power Rating [dB(A)]8 69 69 74 Performance Heating Input BTUH - 1st Stage (Natural Gas) 56250 72000 72000 Input BTUH - 2nd Stage (Natural Gas) 75000 96000 96000 AFUE 80.0 80.0 80 Temp. Rise — Min/

Summary of the content on the page No. 7

General Data MODEL 4YCY4048A1096A 4YCY4048A3096A 4YCY4048A1120A RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/3/60 Performance Cooling BTUH 48000 48000 48000 Indoor Airflow (CFM) 1605 1605 1605 Power Input (KW) 4.034 4.034 4.034 EER/SEER(BTU/Watt-Hr.) 11.9 / 14.2 11.9 / 14.2 11.9 / 14.2 Sound Power Rating [dB(A)]8 73 73 73 Performance Heating Input BTUH - 1st Stage (Natural Gas) 72000 72000 90000 Input BTUH - 2nd Stage (Natural Gas) 96000 120000 96000 AFUE 80.0 80.0 80.0 Temp. Rise —

Summary of the content on the page No. 8

General Data 4YCY4060A1120A 4YCY4060A3120A MODEL 4YCY4048A3120A RATED Volts/PH/Hz 208-230/3/60 208-230/1/60 208-230/3/60 58500 58500 Performance Cooling BTUH 48000 Indoor Airflow (CFM) 1605 1800 1800 5.478 Power Input (KW) 4.034 5.478 EER/SEER(BTU/Watt-Hr.) 11.9 / 14.2 11.9 / 14.0 11.9 / 14.0 76 76 Sound Power Rating [dB(A)]8 73 Performance Heating 90000 90000 Input BTUH - 1st Stage (Natural Gas) 90000 Input BTUH - 2nd Stage (Natural Gas) 120000 120000 120000 80.0 AFUE 80.0 80.0 Temp. Rise

Summary of the content on the page No. 9

Performance Data Cooling 4YCY4030A1 AT 1000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AMB WB CAP 72 75 78 80 KW AIR FLOW CAPACITY TOTAL POWER 59 29.8 24.1 26.9 29.2 28.9 2.3 RATE, CFM MULTIPLIER MULTIPLIER 63 31.0 19.7 22.6 25.5 27.4 2.3 85 LOW 875 0.97 0.98 67 33.4 15.8 18.6 21.5 23.4 2.3 HIGH 1125 1.03 1.02 71 36.1 11.8 14.6 17.5 19.4 2.3 59 27.3 23.0 25.8 27.3 27.3 2

Summary of the content on the page No. 10

Performance Data Cooling 4YCY4042A1 AT 1400 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AMB WB CAP 72 75 78 80 KW AIR FLOW CAPACITY TOTAL POWER 59 40.3 34.1 38.4 40.3 40.3 3.1 RATE, CFM MULTIPLIER MULTIPLIER 63 42.0 27.7 31.9 36.2 39.0 3.1 85 LOW 1225 0.97 0.98 67 45.3 21.8 26.1 30.3 33.2 3.2 HIGH 1575 1.03 1.02 71 48.9 15.9 20.2 24.4 27.3 3.2 59 37.6 32.9 37.2 37.6 37.6

Summary of the content on the page No. 11

Indoor Blower Performance Indoor Fan Performance 4YCY4024A Horizontal Airflow 4YCY4024A-HOR External Static Pressure (in. wg) Motor Speed 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 52 66 89 115 140 164 186 206 229 259 300 LOW CFM 706 716 727 733 731 719 700 679 662 659 682 Watts - 94 120 148 177 207 233 254 267 290 320 MED* CFM - 793 805 813 813 806 793 780 778 799 800 Watts - - 125 153 182 211 243 284 342 426 551 HIGH CFM - - 877 892 903 904 897 884 869 863 877 Down Airflow 4YCY4024A-DOWN Ex

Summary of the content on the page No. 12

Indoor Blower Performance Indoor Fan Performance 4YCY4036A Horizontal Airflow 4YCY4036A-HOR External Static Pressure (in. wg) Motor Speed 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 162 173 197 226 256 285 313 343 383 440 525 LOW CFM 1058 1062 1063 1063 1062 1060 1057 1053 1048 1042 1033 Watts 179 230 265 296 329 366 403 431 450 485 555 MED* CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 1169 1144 Watts 318 336 365 399 435 469 502 533 563 - - HIGH CFM 1390 1376 1370 1366 1361 1354 1349 1351

Summary of the content on the page No. 13

Indoor Blower Performance Indoor Fan Performance 4YCY4048A Horizontal Airflow 4YCY4048A-HOR External Static Pressure (in. wg) Motor Speed 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 200 220 250 285 320 354 386 417 449 487 538 LOW CFM 1407 1394 1396 1403 1408 1408 1402 1391 1380 1377 1392 Watts 268 316 354 386 417 448 483 520 559 597 630 MED* CFM 1584 1608 1616 1615 1608 1600 1593 1586 1579 1568 1550 Watts 378 430 478 522 563 602 640 679 717 758 - HIGH CFM 1798 1821 1830 1833 1831 1828 1825 182

Summary of the content on the page No. 14

Indoor Blower Performance Heating Airflow, horizontal or downflow from .2 to .6” wg. 4YCY4024A1064 4YCY4042A Switch Settings Selection Nominal Airflow Switch Settings Selection Nominal Airflow Low Stage High Stage Low Stage High Stage 7-OFF 8-OFF A 600 850 7-OFF 8-OFF A 1075 1375 7-ON 8-OFF B 625 900 7-ON 8-OFF B 1100 1450 7-OFF 8-ON C 650 925 7-OFF 8-ON C 1150 1500 7-ON 8-ON D 700 975 7-ON 8-ON D 1200 1575 4YCY4030A 4YCY4048A*096 Switch Settings Selection Nominal Airflow Switch Settings Selecti

Summary of the content on the page No. 15

Typical Field Wiring UNIT CONTROL BOX B COMMON (GR) FAN G Y COMPRESSOR (WH) W1 HEAT FIRST STAGE HEAT SECOND STAGE (WH) W2 R 24V GROUND WIRE 1 PH POWER 3 PH POWER UNIT NOTE 1 B B COMMON FAN(GR) G Y COMPRESSOR G (GR) HEAT FIRST STAGE (WH) W1 (WH) HEAT SECOND STAGE W2 Y R 24V W1 (WH) W2 (WH) R C 757192i2 15

Summary of the content on the page No. 16

Typical Wiring 16

Summary of the content on the page No. 17

Typical Wiring From Dwg. 21D757165 P02 17

Summary of the content on the page No. 18

Optional Equipment BAYCURB050A Full Perimeter Roof Mounting Curb for *****018-036A 17 7/8 46 3/8 3 3 5/8 19 1/2 2 3/16 19 1/2 15 38 7/8 14 1 1/2 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liabili

Summary of the content on the page No. 19

Optional Equipment BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060A 15 7/8 56 1/8 3 1 1/2 10 7/8 19 1/2 20 4 3/4 19 1/2 41 7/8 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liabilit

Summary of the content on the page No. 20

Optional Equipment BAYFLTR101, 201B, 1" - 2" Filter Rack (Mounts in Filter/Coil Section) Filter BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and ex


Alternative user manuals
# User manual Category Download
1 Trane 22-5202-03-3605 User manual Heat Pump 0
2 Trane 2TWB0-UM-2 User manual Heat Pump 0
3 Trane 4TWX6 User manual Heat Pump 1
4 Trane 2TWB-SVU01A-EN User manual Heat Pump 1
5 Trane 4TWX6036B User manual Heat Pump 2
6 Trane 4TWX6048B User manual Heat Pump 1
7 Trane 4TWX606OB User manual Heat Pump 0
8 Trane 4TWX6024B User manual Heat Pump 0
9 Trane 4YCY4024A User manual Heat Pump 5
10 Trane EXWA User manual Heat Pump 7
11 Trane GETB User manual Heat Pump 2
12 Trane GEH User manual Heat Pump 27
13 Trane GEV User manual Heat Pump 3
14 Trane GSWD User manual Heat Pump 0
15 Trane PKGP-PRC003-EN User manual Heat Pump 1
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5