Goodman Mfg SS-GSH10C user manual

User manual for the device Goodman Mfg SS-GSH10C

Device: Goodman Mfg SS-GSH10C
Category: Heat Pump
Manufacturer: Goodman Mfg
Size: 0.84 MB
Added : 7/6/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Goodman Mfg SS-GSH10C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Goodman Mfg SS-GSH10C.

For your convenience

If looking through the Goodman Mfg SS-GSH10C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Goodman Mfg SS-GSH10C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Goodman Mfg SS-GSH10C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Goodman Mfg SS-GSH10C User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Goodman Mfg SS-GSH10C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Goodman Mfg SS-GSH10C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

GSH10 Comm ERCial
11 EER Split SS y E t m
HEta p ump
7½ ot 10 t S on
Standard Features
• Energ y-efficient compr essor with internal pr essur e
r elief valve
• High-ca pacity , steel-cased, bi-flow hea t pump
filter dr y er
• Factor y-installed suction line accumula tor
• Liquid r efrigerant r eturn pr otection
• Check flowra ter hea ting mode expansion de vice
• Relia ble, time-initia ted, tempera tur e-termina ted
defr ost contr ol
• Low-pr essur e switch
• Discharge

Summary of the content on the page No. 2

p RoduCt SpECifiCtionS a p RoduCt SEC p ifiCtionS a n omEC n tuRE la G S H 10 120 3 A A   1 2 3 4,5 6,7,8 9 10 11 B r a n d Engine e r ing  * G Goodman®  br and Mino r  R e vision Engine e r ing  * Pr o d u ct  Ca t eg o r y Major  R e vision S Split  S y s t em Ele c tr ic al Unit  T ype 3  =  208/230  V ,  3  Phase,  60  Hz C Condenser  R-­‐22 H Hea t  Pump  R-­‐22 Nom inal  C apac ity E ffic ie nc y 090 7½  T o n s 120        10  T o n s

Summary of the content on the page No. 3

p RoduCt SpECifiCtionS a p RoduCt SpECifiCtionS a SEC p C ifi S tiona GSH10 GSH10 GSH10 0903A* 0903B* 1203A* Nominal Capacities Cooling (BTU/h) 87,000 90,000 110,000 Heating (BTU/h) 84,000 84,000 100,000 EER/IEER 11/-- 11/11 11/11.5 Decibels 76 76 77 Compressor RLA 25.6 25.6 30.1 LRA 196 196 225 Condenser Fan Motor Horsepower 1 1 1 FLA 5.6 5.6 5.6 Refrigerant Lines Liquid Valve Size (“O.D.) ⅝" ⅝" ⅝" Suction Valve Size (“O.D.) (7½ tons) 1⅜" 1⅜" 1⅜" Suction Valve Size (“O.D.) (10 tons) 1⅝" 1⅝" 1⅝"

Summary of the content on the page No. 4

p RoduCt SpECifiCtionS a p RoduCt SpECifiCtionS a EE andxp d CoolinG d ata — GSH100903a * / aR090 4 www.goodmanmfg.com SS-GSH10C Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 85.3 88.4 96.8 - 83.3 86.3 94.6 - 81.3 84.3 92.3 - 79.3 82.2 90.1 - 75.3 78.1 85.6 - 69.8 72.3 79.3 - S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.47 - 0.83 0.70 0.

Summary of the content on the page No. 5

p RoduCt SpECifiCtionS a p RoduCt SpECifiCtionS a EE andxp d CoolinG d ata — GSH100903a * / aR090 ( Cont .) SS-GSH10C www.goodmanmfg.com 5 Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 88.24 90.17 96.33 102.98 86.19 88.07 94.09 100.58 84.13 85.97 91.85 98.19 82.08 83.87 89.61 95.79 77.98 79.68 85.13 91.00 72.23 73.81 78.86 84.30 S/T 0.91 0.86 0.70 0.52 0.95 0

Summary of the content on the page No. 6

p RoduCt SpECifiCtionS a p RoduCt SpECifiCtionS a EE andxp d CG oolin d ata — GSH100903B* / R090 a 6 www.goodmanmfg.com SS-GSH10C Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 84.9 88.0 96.4 - 82.9 86.0 94.2 - 81.0 83.9 92.0 - 79.0 81.9 89.7 - 75.0 77.8 85.2 - 69.5 72.1 78.9 - S/T 0.67 0.56 0.39 - 0.70 0.58 0.40 - 0.71 0.60 0.41 - 0.74 0.62 0.43 - 0.77 0.64 0

Summary of the content on the page No. 7

p RoduCt SpECifiCtionS a p RoduCt SpECifiCtionS a EE andxp d CoolinG d ata — GSH100903B* / aR090 ( Cont .) SS-GSH10C www.goodmanmfg.com 7 Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 87.9 89.8 96.0 102.6 85.9 87.7 93.7 100.2 83.8 85.6 91.5 97.8 81.8 83.6 89.3 95.4 77.7 79.4 84.8 90.7 72.0 73.5 78.6 84.0 S/T 0.84 0.79 0.64 0.48 0.87 0.81 0.66 0.50 0.89 0.84 0

Summary of the content on the page No. 8

p RoduCt SpECifiCtionS a p RoduCt SpECifiCtionS a EE andxp d CoolinG d ata — GSH101203a * / R12 a 0 8 www.goodmanmfg.com SS-GSH10C Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 106.8 110.7 121.3 - 104.3 108.1 118.5 - 101.8 105.6 115.7 - 99.4 103.0 112.8 - 94.4 97.8 107.2 - 87.4 90.6 99.3 - S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46

Summary of the content on the page No. 9

p RoduCt SpECifiCtionS a p RoduCt SpECifiCtionS a EE andxp d CoolinG d ata — GSH101203a * / R12 a 0 ( Cont .) SS-GSH10C www.goodmanmfg.com 9 Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 110.55 112.97 120.69 129.02 107.98 110.34 117.88 126.02 105.41 107.71 115.08 123.02 102.84 105.08 112.27 120.02 97.70 99.83 106.66 114.02 90.50 92.47 98.80 105.61 S/T 0.90 0.

Summary of the content on the page No. 10

p RoduCt SpECifiCtionS a p RoduCt SpECifiCtionS a EE andxp d HEtinG a d ata GSH100903A* / AR090 Outdoor Ambient Temperature 65°F 60°F 55°F 50°F 47°F 45°F 40°F 35°F 30°F 25°F 20°F 17°F 15°F 10°F 5°F 0°F -5°F -10°F MBh 103.1 97.6 91.8 85.9 82.0 79.5 73.8 68.1 66.0 61.0 56.1 53.0 51.0 45.8 40.6 35.4 30.2 24.8 ∆T 33.1 31.4 29.5 27.6 26.4 25.5 23.7 21.9 21.2 19.6 18.0 17.0 16.4 14.7 13.1 11.4 9.7 8.0 kW 8.04 7.89 7.74 7.59 7.50 7.44 7.29 7.14 7.48 7.32 7.16 7.06 7.00 6.83 6.67 6.51 6.34 6.18 Amps 24.

Summary of the content on the page No. 11

p RoduCt SpECifiCtionS a p RoduCt SEC p ifiCtionS a WIRING DIAGRAMS GSH10*****A* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WiRinG d ia GRam UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. a rning Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 18 SS-GSH10C www.goodmanmfg.com 11 Wiring is subject to change. Always High Voltage: Disconnect a

Summary of the content on the page No. 12

Poductr SPtionS ecifica Poductr SPtionS ecifica d S imen S ion W D Dimensions Model W" D" H" H GSH100903** 35½ 35½ 41½ GSH101203** 35½ 35½ 37½ a cceSSorieS GSH10 GSH10 Model De s crip tion 090** 120** • ABK-20 Anchor Bracket Kit X X AFE18-60A All-fuel Kit X X FSK01A¹ Freeze Protection Kit X X OT18-60A² Outdoor Thermostat with Lockout Stat X X • Contains 20 brackets; four brackets needed to anchor unit to pad ¹ Installed on indoor coil ² Required for heat pump applications where ambient te


Alternative user manuals
# User manual Category Download
1 Goodman Mfg . Co. LP.ENERGY-EFFICIENT User manual Heat Pump 3
2 Goodman Mfg . Co. LP.gsz11 remote s User manual Heat Pump 0
3 Goodman Mfg . Co. LP.GSZ110904AB User manual Heat Pump 0
4 Goodman Mfg . Co. LP.GSZ110903AB User manual Heat Pump 1
5 Goodman Mfg . Co. LP.GSZ110904AA User manual Heat Pump 0
6 Goodman Mfg . Co. LP.GSZ110903AA User manual Heat Pump 0
7 Goodman Mfg . Co. LP.GSZ111203AB User manual Heat Pump 7
8 Goodman Mfg . Co. LP.GSZ111204AA User manual Heat Pump 0
9 Goodman Mfg . Co. LP.GSH13 Remote User manual Heat Pump 8
10 Goodman Mfg . Co. LP.GSZ111203AA User manual Heat Pump 1
11 Goodman Mfg . Co. LP.GSZ111204AB User manual Heat Pump 0
12 Goodman Mfg . Co. LP.RP-430C User manual Heat Pump 5
13 Goodman Mfg . Co. LP.GSZ13 User manual Heat Pump 19
14 Goodman Mfg . Co. LP.SS-ICPKF User manual Heat Pump 1
15 Goodman Mfg GPH1324M41AB User manual Heat Pump 0
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5