Goodman Mfg GSZ/VSZ 13 SEER user manual

User manual for the device Goodman Mfg GSZ/VSZ 13 SEER

Device: Goodman Mfg GSZ/VSZ 13 SEER
Category: Heat Pump
Manufacturer: Goodman Mfg
Size: 0.51 MB
Added : 7/6/2014
Number of pages: 43
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Goodman Mfg GSZ/VSZ 13 SEER. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Goodman Mfg GSZ/VSZ 13 SEER.

For your convenience

If looking through the Goodman Mfg GSZ/VSZ 13 SEER user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Goodman Mfg GSZ/VSZ 13 SEER on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Goodman Mfg GSZ/VSZ 13 SEER to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Goodman Mfg GSZ/VSZ 13 SEER User manual - Online PDF
Advertisement
« Page 1 of 43 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Goodman Mfg GSZ/VSZ 13 SEER but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Goodman Mfg GSZ/VSZ 13 SEER. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL AL
GSZ/VSZ 13 SEER
Split System Heat Pumps
• Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in the Service Manual.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman doe

Summary of the content on the page No. 2

PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. G S Z 13 024 1 A A ELECTRICAL: 1: 208-230v MINOR REVISION: 1ph/60Hz PRODUCT A: Initial Release FAMILY: 3: 208-230v S: Split System 3ph/60Hz 4: 460v SEER: 3ph/60Hz SEER Rating BRAND: ® MAJOR REVISION: G: Goodman Brand A: Initial Release (Standard Feature Set Model) ® S: Goodman Deluxe V: Valu

Summary of the content on the page No. 3

PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. GSZ130181A* VSZ130181A* GSZ130241A* VSZ130241A* GSZ130301A* VSZ130301A* GSZ130361A* VSZ130361A* GSZ130421A* VSZ130421A* GSZ130481A* VSZ130481A* GSZ130601A* VSZ130601A* GSZ130241B* VSZ130241B* GSZ130361B* VSZ130361B* GSZ130363A* GSZ130483A* GSZ130484A* GSZ130603A* GSZ130604A* * Indicates minor revision & is not

Summary of the content on the page No. 4

PRODUCT DESIGN NOTE: This unit cannot be completely enclosed. At least GSZ/VSZ13 models are available in 1 1/2 through 5 ton sizes one side must be unrestricted. and use R-410A refrigerant. They are designed for 208/230 These clearances will help avoid air recirculation. If installing volt single phase applications. two or more units at the same location, allow at least 24 Select GSZ13 models are available in 208/230 and 460 volt inches between units. If only one side is restricted (for ex- 3-p

Summary of the content on the page No. 5

PRODUCT DESIGN Product Dimensions Model Dimensions - W x D x H G/VSZ130181A* 26 x 26 x 32¼ G/VSZ130241A* 26 x 26 x 32¼ G/VSZ130241B* 26 x 26 x 32½ G/VSZ130301A* 26 x 26 x 32¼ G/VSZ130361A* 29 x 29 x 38¼ GSZ130363A* G/VSZ130361B* 29 x 29 x 32½ G/VSZ130421A* 29 x 29 x 38¼ G/VSZ130481A* GSZ130483A* 29 x 29 x 34¼ GSZ130484A* G/VSZ130601A* GZX130603A* 35½ x 35½ x 34¼ GSZ130604A* 5

Summary of the content on the page No. 6

HEAT PUMP SPECIFICATIONS G/VSZ130[18-60]1A* Nominal Capacities Cooling Capacity, BTUH 18,000 24,000 30,000 36,000 42,000 48,000 60,000 Heating Capacity, BTUH 17,000 23,000 26,400 34,000 40,500 44,000 58,000 Compressor R.L. Amps 9.0 12.8 14.1 16.6 17.9 19.8 26.4 L.R. Amps 48.0 58.3 73.0 79.0 112.0 109.0 134.0 Low Pressure Switch Open 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG High Pressure Switch Open 610 PSIG 610 PSIG 610

Summary of the content on the page No. 7

HEAT PUMP SPECIFICATIONS G/VSZ130[24,36]B* Nom inal Capacities Cooling Capacity, B TUH 24,000 36,000 Heating Capacity, B TUH 23,000 34,000 Com pressor R.L. A m ps 12.8 16.7 L.R. A m ps 58.3 79.0 Low P ressure S witch Open 22 PSIG 22 PSIG Close 50 P S IG 50 P SIG High Pressure Switch Open 610 P S IG 610 PS IG Close 420 P S IG 420 PS IG Condenser Fan M otor Horsepower 1/6 1/4 F.L. A m ps 1.10 1.50 Liquid Line, Inches O .D.* 3/8" 3/8" S uction Line, Inches O.D.* 3/4" 3/4" Refrigerant Charge 113.0 1

Summary of the content on the page No. 8

HEAT PUMP SPECIFICATIONS GSZ130[36-60][3,4]A* Nominal Capacities Cooling Capacity, BTUH 36,000 48,000 48,000 60,000 60,000 Heating Capacity, BTUH 34,000 44,000 44,000 58,000 58,000 Decibels 74 767675 75 Compressor R.L. Amps 10.4 13.1 6.1 16.0 7.8 L.R. Amps 73.0 83.1 41.0 110.0 52.0 Type Scroll Scroll Scroll Scroll Scroll Condenser Fan Motor Horsepower 1/4 1/4 1/4 1/4 1/4 F.L. Amps 1.50 1.50 0.80 1.50 0.80 Refrigerant System 3 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8" 3/8" 3 7/8" 1 1/8" 1 1/8

Summary of the content on the page No. 9

COOLING PERFORMANCE DATA G/VSZ130181A* 9 MODEL: G/VSZ130181A* / AR*F182416** EXPANDED PERFORMANCE DATA COOLING OPERATION Outdoor Am bient Te m perature 65 75 85 95 105 115 Ente ring Indoor Wet Bulb Tem pe rature IDB*Airflow 5963 67 71 59 63 677159636771 59 63 67 71 59 63 677159636771 MBh 17.1 17.7 19.4 - 16.7 17.3 18.9 - 16.3 16.9 18.5 - 15.9 16.4 18.0 - 15.1 15.6 17.1 - 14.0 14.5 15.9 - S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0

Summary of the content on the page No. 10

COOLING PERFORMANCE DATA G/VSZ130181A* 10 MODEL: G/VSZ130181A* / AR*F182416** EXPANDED PERFORMANCE DATA COOLING OPERATION Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 596367 715963 677159 636771 59 63 67 7159 636771 596367 71 MBh 17.6 18.0 19.3 20.6 17.2 17.6 18.8 20.1 16.8 17.2 18.4 19.6 16.4 16.8 17.9 19.2 15.6 15.9 17.0 18.2 14.4 14.8 15.8 16.9 S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 1.0

Summary of the content on the page No. 11

COOLING PERFORMANCE DATA G/VSZ130241A* 11 MODEL: G/VSZ130241A* / AR*F182416** EXPANDED PERFORMANCE DATA COOLING OPERATION Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59 63 67 71 59 636771 5963 67 7159 63 67 71596367715963 6771 MBh 22.5 23.4 25.6 - 22.0 22.8 25.0 - 21.5 22.3 24.4 - 21.0 21.7 23.8 - 19.9 20.6 22.6 - 18.4 19.1 21.0 - S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0.49 - DT

Summary of the content on the page No. 12

COOLING PERFORMANCE DATA G/VSZ130241A* 12 MODEL: G/VSZ130241A* / AR*F182416** EXPANDED PERFORMANCE DATA COOLING OPERATION Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59 63 67 71 59 6367715963 67 7159 63 67 71 59 63 67 7159636771 MBh 23.3 23.8 25.5 27.2 22.8 23.3 24.9 26.6 22.2 22.7 24.3 26.0 21.7 22.2 23.7 25.3 20.6 21.1 22.5 24.1 19.1 19.5 20.8 22.3 S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00

Summary of the content on the page No. 13

COOLING PERFORMANCE DATA G/VSZ130241B* 13 EXPANDED PERFORMANCE DATA MODEL: G/VSZ130241B*/ AR*F182416** COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 22.5 23.4 25.6 - 22.0 22.8 25.0 - 21.5 22.3 24.4 - 21.0 21.7 23.8 - 19.9 20.6 22.6 - 18.4 19.1 21.0 - S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.5

Summary of the content on the page No. 14

COOLING PERFORMANCE DATA G/VSZ130241B* 14 EXPANDED PERFORMANCE DATA MODEL: G/VSZ130241B*/ AR*F182416** COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 23.33 23.84 25.47 27.22 22.79 23.28 24.87 26.59 22.24 22.73 24.28 25.96 21.70 22.17 23.69 25.32 20.62 21.07 22.51 24.06 19.10 19.51 20.85 22.29 S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0

Summary of the content on the page No. 15

COOLING PERFORMANCE DATA G/VSZ130301A* 15 MODEL: G/VSZ130301A* / AR*F30301** EXPANDED PERFORMANCE DATA COOLING OPERATION Outdoor Am bie nt Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59636771 59 63677159 63 677159 63 67 71 5963677159 636771 MBh 27.4 28.4 31.1 - 26.8 27.8 30.4 - 26.1 27.1 29.7 - 25.5 26.4 29.0 - 24.2 25.1 27.5 - 22.4 23.3 25.5 - S/T 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.81 0.67 0.47 - 0.83 0.70 0.48 - 0.87 0.72 0.50 - 0.87 0.73 0.51 - DT 16

Summary of the content on the page No. 16

COOLING PERFORMANCE DATA G/VSZ130301A* 16 MODEL: G/VSZ130301A* / AR*F30301** EXPANDED PERFORMANCE DATA COOLING OPERATION Outdoor Am bient Te m perature 65 75 85 95 105 115 Ente ring Indoor Wet Bulb Te m perature IDB*Airflow 5963 67 71 59 63677159 63 677159 63 67 7159 63 67 7159636771 MBh 28.429.031.033.127.728.330.3 32.4 27.1 27.7 29.5 31.626.4 27.0 28.8 30.825.125.627.429.323.223.7 25.4 27.1 S/T 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 0.98 0.79 0.59 1.00 1.00 0.82 0.

Summary of the content on the page No. 17

COOLING PERFORMANCE DATA G/VSZ130361A* 17 MODEL: G/VSZ130361A* / AR*F364216** EXPANDED PERFORMANCE DATA COOLING OPERATION Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 33.8 35.0 38.4 - 33.0 34.2 37.5 - 32.2 33.4 36.6 - 31.4 32.6 35.7 - 29.9 31.0 33.9 - 27.7 28.7 31.4 - S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71

Summary of the content on the page No. 18

COOLING PERFORMANCE DATA G/VSZ130361A* 18 MODEL: G/VSZ130361A* / AR*F364216** EXPANDED PERFORMANCE DATA COOLING OPERATION Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59 63 6771 59 6367 71 59 63 677159 63 67 71596367715963 6771 MBh 34.98 35.75 38.19 40.82 34.17 34.91 37.30 39.88 33.35 34.08 36.41 38.93 32.54 33.25 35.53 37.98 30.91 31.59 33.75 36.08 28.64 29.26 31.26 33.42 S/T 0.92 0.87 0.70 0.53 0.96 0.90 0.73 0.55 0.98 0.92 0.75 0.56 1.0

Summary of the content on the page No. 19

COOLING PERFORMANCE DATA G/VSZ130361B* 19 EXPANDED PERFORMANCE DATA MODEL: G/VSZ130361B* / AR*F364216** COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 34.3 35.5 38.9 - 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.9 33.1 36.2 - 30.3 31.4 34.4 - 28.1 29.1 31.9 - S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.

Summary of the content on the page No. 20

COOLING PERFORMANCE DATA G/VSZ130361B* 20 EXPANDED PERFORMANCE DATA MODEL: G/VSZ130361B* / AR*F364216** COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 35.50 36.27 38.75 41.43 34.67 35.43 37.85 40.46 33.85 34.59 36.95 39.50 33.02 33.74 36.05 38.54 31.37 32.06 34.25 36.61 29.06 29.69 31.72 33.91 S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76


Alternative user manuals
# User manual Category Download
1 Goodman Mfg . Co. LP.ENERGY-EFFICIENT User manual Heat Pump 3
2 Goodman Mfg . Co. LP.gsz11 remote s User manual Heat Pump 0
3 Goodman Mfg . Co. LP.GSZ110904AB User manual Heat Pump 0
4 Goodman Mfg . Co. LP.GSZ110903AB User manual Heat Pump 1
5 Goodman Mfg . Co. LP.GSZ110904AA User manual Heat Pump 0
6 Goodman Mfg . Co. LP.GSZ110903AA User manual Heat Pump 0
7 Goodman Mfg . Co. LP.GSZ111203AB User manual Heat Pump 7
8 Goodman Mfg . Co. LP.GSZ111204AA User manual Heat Pump 0
9 Goodman Mfg . Co. LP.GSH13 Remote User manual Heat Pump 8
10 Goodman Mfg . Co. LP.GSZ111203AA User manual Heat Pump 1
11 Goodman Mfg . Co. LP.GSZ111204AB User manual Heat Pump 0
12 Goodman Mfg . Co. LP.RP-430C User manual Heat Pump 5
13 Goodman Mfg . Co. LP.GSZ13 User manual Heat Pump 19
14 Goodman Mfg . Co. LP.SS-ICPKF User manual Heat Pump 1
15 Goodman Mfg GPH1324M41AB User manual Heat Pump 0
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5