Dimplex SI 7ME user manual

User manual for the device Dimplex SI 7ME

Device: Dimplex SI 7ME
Category: Heat Pump
Manufacturer: Dimplex
Size: 1.65 MB
Added : 2/23/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Dimplex SI 7ME. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Dimplex SI 7ME.

For your convenience

If looking through the Dimplex SI 7ME user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Dimplex SI 7ME on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Dimplex SI 7ME to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Dimplex SI 7ME User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Dimplex SI 7ME but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Dimplex SI 7ME. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SI 5ME
SI 7ME
SI 9ME
Montage- und
Gebrauchsanweisung
SI 11ME
SI 14ME
Installation and
Operating Instructions
Instructions d’installation
et d’utilisation
Sole/Wasser- Brine-to-Water Pompe à chaleur
Wärmepumpe für Heat Pump for eau glycolée-eau
Innenaufstellung Indoor Installation pour installation
intérieure
o
Bestell-Nr. / Order no. / N de commande : 452232.66.13 FD 8705
Français English Deutsch

Summary of the content on the page No. 2

Table of contents 1 Please Read Immediately .............................................................................................................E-2 1.1 Important Information..............................................................................................................................E-2 1.2 Legal Regulations and Directives ...........................................................................................................E-2 1.3 Energy-Efficient Use of the Heat Pum

Summary of the content on the page No. 3

English 1 1.2 Legal Regulations and 1 Please Read Directives Immediately This heat pump conforms to all relevant DIN/VDE regulations and EU directives. Refer to the EC Declaration of Conformity in 1.1 Important Information the appendix for details. The heat pump must be connected to the power supply in com- ATTENTION! pliance with all relevant VDE, EN and IEC standards. Any further The heat pump is not secured to the wooden pallet. connection requirements stipulated by local utility companies

Summary of the content on the page No. 4

3 2 Purpose of the Heat 3 Basic Device The basic device consists of a ready-to-use heat pump for indoor Pump installation, complete with sheet metal casing, control panel and integrated controller. The refrigerating cycle contains the refriger- 2.1 Application ant R407C. R407C refrigerant is CFC-free, non-ozone depleting and non-combustible. The brine-to-water heat pump is designed for use in existing or All components required for the operation of the heat pump are newly built heating systems.

Summary of the content on the page No. 5

English 4 4 Accessories 6Set-up 4.1 Brine Circuit Manifold 6.1 General Information The brine circuit manifold merges the individual collector loops of The unit may only be installed indoors in rooms with low humidity the heat source system into a single main pipe which is con- on a level, smooth and horizontal surface. The entire base of the nected to the heat pump. Integrated ball valves allow the individ- frame should lie directly on the floor to ensure a good soundproof ual brine circuits to

Summary of the content on the page No. 6

7.4 7.3 Heat Source Connection 7 Installation The following procedure must be observed when connecting the heat source: 7.1 General Information Connect the brine pipe to the heat pump flow and return. The hy- The following connections need to be established on the heat draulic plumbing diagram must be adhered to. pump: Flow and return flow of the brine system ATTENTION! Flow and return flow of the heating system The supplied dirt trap must be inserted in the heat source inlet of the heat pump

Summary of the content on the page No. 7

English 8 8.3 Start-up Procedure 8 Commissioning The heat pump is started up via the heat pump controller. 8.1 General Information ATTENTION! To ensure that start-up is performed correctly, it should only be The heat pump must be started up in accordance with the installation and carried out by an after-sales service technician authorised by the operating instructions of the heat pump controller. manufacturer. This may be a condition for extending the guaran- If an overflow valve is fitted to as

Summary of the content on the page No. 8

11 9 Maintenance and 10 Faults / Trouble- Cleaning Shooting This heat pump is a quality product and is designed for trouble- free operation. In the event that a fault should occur, it will be in- 9.1 Maintenance dicated on the heat pump manager display. Simply consult the The heat pump is maintenance-free. To prevent faults due to Faults and Trouble-Shooting page in the operating instructions of sediment in the heat exchangers, care must be taken to ensure the heat pump controller. that no impur

Summary of the content on the page No. 9

English 12 12 Device Information 1 Type and order code SI 5ME SI 7ME SI 9ME SI 11ME SI 14ME 2Design 2.1 Degree of protection according to EN 60 529 IP 20 IP 20 IP 20 IP 20 IP 20 2.2 Installation Location Indoors Indoors Indoors Indoors Indoors 3 Performance data 3.1 Operating temperature limits: Heating water flow °C Up to 58 Up to 58 Up to 58 Up to 58 Up to 58 Brine (heat source) °C -5 to +25 -5 to +25 -5 to +25 -5 to +25 -5 to +25 Mono-ethyl- Mono-ethyl- Mono-ethyl- Mono-ethyl- Mono-ethyl- Ant

Summary of the content on the page No. 10

Anhang / Appendix / Annexes 1 Maßbilder / Dimension Drawings / Schémas cotés................................................................... A-II 1.1 Maßbild / Dimension Drawing / Schéma coté.........................................................................................A-II 2 Diagramme / Diagrams / Diagrammes....................................................................................... A-III 2.1 Kennlinien / Characteristic Curves / Courbes caractéristiques SI 5ME ..........

Summary of the content on the page No. 11

Anhang · Appendix · Annexes 1 1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Maßbild / Dimension Drawing / Schéma coté A-II

Summary of the content on the page No. 12

2.1 2 Diagramme / Diagrams / Diagrammes 2.1 Kennlinien / Characteristic Curves / Courbes caractéristiques SI 5ME www.dimplex.de A-III Anhang · Appendix · Annexes

Summary of the content on the page No. 13

Anhang · Appendix · Annexes 2.2 2.2 Kennlinien / Characteristic Curves / Courbes caractéristiques SI 7ME A-IV

Summary of the content on the page No. 14

2.3 2.3 Kennlinien / Characteristic Curves / Courbes caractéristiques SI 9ME www.dimplex.de A-V Anhang · Appendix · Annexes

Summary of the content on the page No. 15

Anhang · Appendix · Annexes 2.4 2.4 Kennlinien / Characteristic Curves / Courbes caractéristiques SI 11ME A-VI

Summary of the content on the page No. 16

2.5 2.5 Kennlinien / Characteristic Curves / Courbes caractéristiques SI 14ME www.dimplex.de A-VII Anhang · Appendix · Annexes

Summary of the content on the page No. 17

Anhang · Appendix · Annexes 3 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung / Control / Commande A-VIII

Summary of the content on the page No. 18

3.2 3.2 Last / Load / Charge www.dimplex.de A-IX Anhang · Appendix · Annexes

Summary of the content on the page No. 19

Anhang · Appendix · Annexes 3.3 3.3 Klemmenanschlussplan / Terminal Connection Plan / Schéma de connexion des bornes A-X

Summary of the content on the page No. 20

3.4 3.4 Legende / Legend / Légende A1 Drahtbrücke, muss eingelegt werden, wenn kein Wire jumper, must be inserted if no blocking con- Le cavalier à fil doit être inséré en absence de dis- Sperrschütz vorhanden ist tactor is fitted joncteur de blocage du fournisseur d'énergie. A2 Drahtbrücke, muss bei Verwendung des 2ten Sper- Wire jumper, must be removed if the 2nd disable Cavalier à fil à retirer si la 2e entrée de coupure est reinganges entfernt werden contactor is used utilisée A3 Drahtbrück


Alternative user manuals
# User manual Category Download
1 Dimplex LI 11TER+ User manual Heat Pump 3
2 Dimplex LI 16TER+ User manual Heat Pump 3
3 Dimplex User manual Heat Pump 0
4 Dimplex LA 11PS User manual Heat Pump 0
5 Dimplex LA 12PS User manual Heat Pump 0
6 Dimplex LA 12TR User manual Heat Pump 0
7 Dimplex LA 10MR User manual Heat Pump 0
8 Dimplex LA 17PS User manual Heat Pump 10
9 Dimplex LA 16TR User manual Heat Pump 0
10 Dimplex LA 18PS User manual Heat Pump 3
11 Dimplex LA 22PS User manual Heat Pump 0
12 Dimplex LA 6MR User manual Heat Pump 1
13 Dimplex LA 26PS User manual Heat Pump 2
14 Dimplex LA 8MR User manual Heat Pump 3
15 Dimplex LA16ASR User manual Heat Pump 2
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5