Dimplex SI 24TE SI 37TE user manual

User manual for the device Dimplex SI 24TE SI 37TE

Device: Dimplex SI 24TE SI 37TE
Category: Heat Pump
Manufacturer: Dimplex
Size: 1.64 MB
Added : 2/23/2014
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Dimplex SI 24TE SI 37TE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Dimplex SI 24TE SI 37TE.

For your convenience

If looking through the Dimplex SI 24TE SI 37TE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Dimplex SI 24TE SI 37TE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Dimplex SI 24TE SI 37TE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Dimplex SI 24TE SI 37TE User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Dimplex SI 24TE SI 37TE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Dimplex SI 24TE SI 37TE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SI 24TE
SI 37TE
Montage- und
Gebrauchsanweisung
Installation and
Operating Instructions
Instructions d’installation
et d’utilisation
Sole/Wasser- Brine-to-Water Pompe à chaleur
Wärmepumpe für Heat Pump for eau glycolée-eau
Innenaufstellung Indoor Installation pour installation
intérieure
o
Bestell-Nr. / Order no. / N de commande : 452234.66.10 FD 8609
Français English Deutsch

Summary of the content on the page No. 2

Table of contents 1 Read immediately..........................................................................................................................E-2 1.1 Important Information..............................................................................................................................E-2 1.2 Legal Provisions and Guidelines ............................................................................................................E-2 1.3 Energy-Efficient Use of the Hea

Summary of the content on the page No. 3

English 1 1.3 Energy-Efficient Use of the 1 Read immediately Heat Pump 1.1 Important Information By operating this heat pump you contribute to the protection of our environment. A prerequisite for an efficient operation is the ATTENTION! proper design and sizing of the heating system and the heat Any work on the heat pump may only be performed by an authorised and source system. In particular, it is important to keep water flow qualified customer service. temperatures as low as possible. All en

Summary of the content on the page No. 4

5 3 Baseline Unit 4 Accessories The baseline unit consists of a heat pump, ready for connection, for indoor installation, complete with sheet metal cabinet, control 4.1 Connecting Flanges box and integrated controller. The refrigeration cycle contains the The use of flat-sealing connecting flanges allows the unit, as an refrigerant R404A. Refrigerant R404A is CFC-free, non-ozone option, to be connected by means of flanges. depleting and non-combustible. All components required for the operation

Summary of the content on the page No. 5

English 6 Heating water minimum flow rate 6 Installation The heating water minimum flow rate through the heat pump must be assured in all operating states of the heating system. 6.1 General Information This can be accomplished, for example, by installing a differential pressure-free manifold or an overflow valve. The procedure for As a rule, the unit must be installed indoors on a level, smooth setting an overflow valve is described in the Chapter Commis- and horizontal surface. The entire base

Summary of the content on the page No. 6

8.3 For more detailed instructions concerning the connection and 8.2 Preparatory Steps functioning of the heat pump controller (e.g. the supplied external Prior to commissioning, the following items need to be checked: wall sensor) please refer to the enclosed operating manual of the controller. All connections of the heat pump must have been made as described in Chapter 7. An automatic circuit-breaker with simultaneous tripping of all ex- ternal conductors is to be provided in the load power s

Summary of the content on the page No. 7

English 9 9 Care/Cleaning 10 Malfunctions / Troubleshooting 9.1 Care This heat pump is a quality product and designed for trouble- and The heat pump is maintenance-free. To prevent malfunctions maintenance-free operation. In the event that a malfunction oc- due to sediments in the heat exchangers, care must be taken curs nevertheless, it will be indicated on the display of the heat that no im-purities can enter the heat source system and the pump controller. Simply consult the Malfunctions and

Summary of the content on the page No. 8

12 12 Equipment Data 1 Type and order code SI 24TE SI 37TE 2Design 2.1 Degree of protection according to EN 60 529 IP 21 IP 21 2.2 Installation location Indoors Indoors 3 Performance data 3.1 Operating temperature limits: Heating water flow °C up to 60 up to 60 Brine (heat source) °C -5 to +25 -5 to +25 Antifreeze Monoethylene glycol Monoethylene glycol Minimum brine concentration (-13 °C freezing temperature) 25% 25% 3.2 Temperature spread of heating water (flow/return flow) at B0 / W35K 9.4 5.

Summary of the content on the page No. 9

Anhang / Appendix / Annexes 1 Maßbilder / Dimensioned drawings / Schémas cotés............................................................... A-II 1.1 Maßbild / Dimensioned drawing / Schéma coté SI 24TE .......................................................................A-II 1.2 Maßbild / Dimensioned drawing / Schéma coté SI 37TE ......................................................................A-III 2 Diagramme / Schematics / Diagrammes ...................................................

Summary of the content on the page No. 10

Anhang · Appendix · Annexes 1 1 Maßbilder / Dimensioned drawings / Schémas cotés 1.1 Maßbild / Dimensioned drawing / Schéma coté SI 24TE A-II

Summary of the content on the page No. 11

1.2 1.2 Maßbild / Dimensioned drawing / Schéma coté SI 37TE www.dimplex.de A-III Anhang · Appendix · Annexes

Summary of the content on the page No. 12

Anhang · Appendix · Annexes 2 2 Diagramme / Schematics / Diagrammes 2.1 Kennlinien / Schematics / Courbes caractéristiques SI 24TE A-IV

Summary of the content on the page No. 13

2.2 2.2 Kennlinien / Schematics / Courbes caractéristiques SI 37TE www.dimplex.de A-V Anhang · Appendix · Annexes

Summary of the content on the page No. 14

Anhang · Appendix · Annexes 3 3 Stromlaufpläne / Wiring diagrams / Schémas électriques 3.1 Steuerung / Control / Commande A-VI

Summary of the content on the page No. 15

3.2 3.2 Last / Load / Charge www.dimplex.de A-VII Anhang · Appendix · Annexes

Summary of the content on the page No. 16

Anhang · Appendix · Annexes 3.3 3.3 Anschlussplan / Terminal diagram / Schéma de branchement A-VIII

Summary of the content on the page No. 17

3.4 3.4 Legende / Legend / Légende A1 Drahtbrücke, muss bei Einsatz eines EVU-Sperr- Wire jumper, must be removed when an A2 utility Enlever le cavalier à fil si un contacteur de coupure schützes entfernt werden blocking contactor is installed du fournisseur d'énergie est utilisé A2 Drahtbrücke, muss bei Verwendung des 2. Sper- Wire jumper, must be removed if 2nd disable input Retirer le cavalier à fil lors de l’*utilisation de la reinganges entfernt werden is used deuxième entrée de coupure A

Summary of the content on the page No. 18

Anhang · Appendix · Annexes 4 4 Hydraulisches Prinzipschema / Hydraulic block diagrams / Schéma hydraulique 4.1 Darstellung / Schematic view / Représentation schématique A-X

Summary of the content on the page No. 19

4.2 4.2 Legende / Legend / Légende Rückschlagventil Check valve Clapet anti-retour Absperrventil Shutoff valve Robinet d’arrêt Dreiwegemischer Three-way mixer Mélangeur 3 voies Umwälzpumpe Circulating pump Circulateur Ausdehnungsgefäß Expansion vessel Vase d´expansion Absperrventil mit Rückschlagventil Shutoff valve with check valve Robinet d’arrêt avec clapet anti-retour Sicherheitsventilkombination Safety valve combination Groupe de valves de sécurité Wärmeverbraucher Heat consumer Consommateu

Summary of the content on the page No. 20

Anhang · Appendix · Annexes 5 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité A-XII


Alternative user manuals
# User manual Category Download
1 Dimplex LI 11TER+ User manual Heat Pump 3
2 Dimplex LI 16TER+ User manual Heat Pump 3
3 Dimplex User manual Heat Pump 0
4 Dimplex LA 11PS User manual Heat Pump 0
5 Dimplex LA 12PS User manual Heat Pump 0
6 Dimplex LA 12TR User manual Heat Pump 0
7 Dimplex LA 10MR User manual Heat Pump 0
8 Dimplex LA 17PS User manual Heat Pump 10
9 Dimplex LA 16TR User manual Heat Pump 0
10 Dimplex LA 18PS User manual Heat Pump 3
11 Dimplex LA 22PS User manual Heat Pump 0
12 Dimplex LA 6MR User manual Heat Pump 1
13 Dimplex LA 26PS User manual Heat Pump 2
14 Dimplex LA 8MR User manual Heat Pump 3
15 Dimplex LA16ASR User manual Heat Pump 2
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5