Conair PD3 user manual

User manual for the device Conair PD3

Device: Conair PD3
Category: Heat Pump
Manufacturer: Conair
Size: 0.23 MB
Added : 8/13/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Conair PD3. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Conair PD3.

For your convenience

If looking through the Conair PD3 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Conair PD3 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Conair PD3 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Conair PD3 User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Conair PD3 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Conair PD3. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Positive
Displacement Pump
Models PD3, 5, 7.5, 10, 15 and 25
Installation
Maintenance
Operation
Troubleshooting
The Conair Group, Inc.
Instant Access
One Conair Drive
Parts and Service
Pittsburgh, PA 15202
(800) 458-1960
Phone: (412) 312-6000
(814) 437-6861
Fax: (412)-312-6320
www.conairnet.com
IMB036/0898

Summary of the content on the page No. 2

It’s a good idea to record the model and serial number(s) of Please record your your equipment and the date you received it in the User equipment’s model and Guide. Our service department uses this information, along serial number(s) and with the manual number, to provide help for the specific the date you received it equipment you installed. Please keep this User Guide and all manuals, engineering prints and parts lists together for documentation of your equipment. Date: Manual Number: IMB036/0

Summary of the content on the page No. 3

INTRODUCTION TABLE OF ATTENTION: Read this first so no one gets hurt . . . . . . . . .1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 CONTENTS Optional Sound Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . .2 SPECIFICATIONS Positive displacement pump . . . . . . . . . . . . . . . . . . . . . . . . .3 Pumps with sound enclosures . . . . . . . . . . . . . . . . . . . . . . . .3 INSTALLATION Installing the pump . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

We design equipment with the user’s safety in mind. You can ATTENTION: avoid the potential hazards identified on this machine by following the procedures outlined below and elsewhere in READ THIS SO NO the User Guide. ONE GETS HURT WARNING: Improper installation, operation or servicing may result in equipment damage or personal injury. This equipment should be installed, adjusted, and serviced by qualified technical personnel who are familiar with the construction, opera- tion and potential ha

Summary of the content on the page No. 5

Conair positive displacement vacuum pumps are designed for DESCRIPTION long distance, high-volume material conveying applications. Each model employs a powerful, rotating lobe-type blower, protected by a vacuum relief valve (factory-set to 12 in. Hg) and belt driven by a three-phase motor with magnetic starter and overload protection. An integrated pump protection filter is included and all components are mounted on a rugged frame, housing an integrated exhaust muffler. An optional sound enclosu

Summary of the content on the page No. 6

SPECIFICATIONS: POSITIVE DISPLACEMENT PUMP Vacuum Inlet H Exhaust D W MODEL PD3 PD5 PD7.5 PD10 PD15 PD25 Motor Type* TEFC TEFC TEFC ODP ODP ODP Performance characteristics Horsepower 3 5 7.5 10 15 25 Standard CFM at material pickup point @ 10" Hg 52.6 76.6 121.2 154.5 201.1 346.2 Average sound level (dbA) @ 8", 10" and 12" Hg 86 86.3 86 85.8 88.8 93 Dimensions / in. {mm} Standard inlet line size (OD) 1.5 {38} 1.75 {44} 2.25 {57} 2.5 {64} 3.0 {76} 4.0 {102} Exhaust line size (OD) 2.5 {64} 2.5 {

Summary of the content on the page No. 7

Set or mount the vacuum pump in any convenient location. INSTALLING Refer to the accompanying wiring diagram for connection of THE PUMP the main power supply and the conveying control circuit.You must provide a wall-mounted disconnect for three-phase elec- trical connection. Incoming voltage and current must match the electrical specifications on the pump data plate and serial tag. Check for proper rotation of the pump after power has been connected and before operation. Install vacuum lines to

Summary of the content on the page No. 8

To maintain the best performance, you should follow the PREVENTATIVE maintenance recommendations outlined here and in any included manuals from component manufacturers. MAINTENANCE l Weekly, or as often as needed SCHEDULE r Check and clean the pump inlet filter. An inlet filter has been provided to protect the pump from solid material that can enter and damage the pump impellers. material can enter the vacuum line if a loader filter is improperly installed or if if has a hole in it. Replace t

Summary of the content on the page No. 9

Conair has made the largest investment in customer support in WE’RE HERE the plastics industry. Our service experts are available to help with any problem you might have installing and operating TO HELP your equipment. Your Conair sales representative also can help analyze the nature of your problem, assuring that it did not result from misapplication or improper use. To contact Customer Service personnel, call: HOW TO CONTACT CUSTOMER From outside the United States, call: 814-437-6861 SERVICE Y

Summary of the content on the page No. 10

Conair guarantees the machinery and equipment on this order, EQUIPMENT for a period as defined in the quotation from date of shipment, against defects in material and workmanship under the normal GUARANTEE use and service for which it was recommended (except for parts that are typically replaced after normal usage, such as filters, liner plates, etc.). Conair’s guarantee is limited to replacing, at our option, the part or parts determined by us to be defective after examination. The customer ass


Alternative user manuals
# User manual Category Download
1 Conair 5 User manual Heat Pump 1
2 Conair 10 User manual Heat Pump 3
3 Conair 7.5 User manual Heat Pump 0
4 Conair 25 User manual Heat Pump 3
5 Edelbrock 15005 User manual Heat Pump 0
6 A.O. Smith AH User manual Heat Pump 2
7 ACS 882.00217.00 User manual Heat Pump 1
8 A.O. Smith AHD 290 User manual Heat Pump 3
9 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5
10 Acnodes Q5RF SERIES User manual Heat Pump 2
11 Amana 10730418 User manual Heat Pump 1
12 Allied Air Enterprises (2 User manual Heat Pump 0
13 Allied Air Enterprises 15) User manual Heat Pump 0
14 Allied Air Enterprises 4HP16LT User manual Heat Pump 2
15 AC International 8200 Series User manual Heat Pump 1