Carrier AQUASNAP 30RA user manual

User manual for the device Carrier AQUASNAP 30RA

Device: Carrier AQUASNAP 30RA
Category: Heat Pump
Manufacturer: Carrier
Size: 1.56 MB
Added : 12/28/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier AQUASNAP 30RA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier AQUASNAP 30RA.

For your convenience

If looking through the Carrier AQUASNAP 30RA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier AQUASNAP 30RA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier AQUASNAP 30RA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier AQUASNAP 30RA User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier AQUASNAP 30RA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier AQUASNAP 30RA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

E
C
N
A
R
U
S
S
A
Y
T
I
I
L
S
A
O
U
9
AQUASNAP
30RA / 30RH
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Q
0
0
R
1
E
PRO-DIALOG control
T
S
I
G
E
R
S
'
D
Y
O
L
L

Summary of the content on the page No. 2

30RA/30RH Air-cooled liquid chillers and reversible air-to-water heat pumps with integrated hydronic module For the use of the control system, refer to the Pro-Dialog Plus control manual. Contents Page Physical data ................................................................................................................................. 2/3 Electrical data ................................................................................................................................ 2/3

Summary of the content on the page No. 3

30RA Physical data and electrical data - Model RA Table I: Physical data - Model RA 30RA 017 021 026 033 Net cooling capacity* kW 17.70 21.60 25.80 31.70 Operating weight without hydronic module kg 200 220 250 285 with hydronic module kg 220 240 280 315 Refrigerant charge R-407C kg 4.80 5.13 6.41 7.70 Compressor One scroll compressor Evaporator One plate heat exchanger Net water volume l 1.50 1.88 2.16 2.82 Water connections (MPT gas) inches 1 1 1-1/4 1-1/4 Maximum water pressure kPa 1000 100

Summary of the content on the page No. 4

30RH Physical data and electrical data - Model RH ENGLISH Table I: Physical data - Model RH 30RH 017 021 026 033 Net cooling capacity* kW 16.70 21.60 24.60 29.00 Net heating capacity** kW 18.80 24.80 27.80 34.00 Operating weight without hydronic module kg 235 265 285 315 with hydronic module kg 255 285 315 345 Refrigerant charge R-407C kg 7.15 7.84 9.30 11.00 Compressor One scroll compressor Control system Pro Dialog-Plus Refrigerant-water heat exchanger One plate heat exchanger Net water volu

Summary of the content on the page No. 5

200 400 30RA/30RH Dimensions and location of hydraulic connections (mm) Mod. 30RA 017 - 021 Mod. 30RA 026 - 033 Mod. 30RH 017 Mod. 30RH 021 - 026 - 033 1503 1328 3 1 3 1 2 180 125 2 175 105 130 1243 130 130 1068 130 12x20 12x20 1. Water inlet 2. Water outlet 3. 3/4” gas safety valve outlet     Main switch  Grommet: 1 Pg 29 and 2 Pg 16 for power supply and control cables entry GB - 4 700 200 635 578 859 478 796 40 1453.5 635 578 1003 478 940 40 1657.5

Summary of the content on the page No. 6

30RA/30RH General information and hydronic module ENGLISH This is necessary to prevent ice from accumulating on the frame Unit installation and to permit correct operation also in the event of heavy Read this instruction manual thoroughly before starting the snowfalls. installation. The unit must be levelled on both axes (the tolerance is less than This unit complies with low-voltage (EEC/73/23) and electro- 2 mm per metre). magnetic compatibility (EEC/89/336) directives. • In some cases it may

Summary of the content on the page No. 7

30RA/30RH Water connections Typical water circuit diagram for units without hydronic module Legend for units without  Mesh filter Pressure couplings hydronic module:  30RA - RH unit Thermometers without hydronic Flow switch module Automatic purge valve  Fan coil units Hydraulic circuit drain  Water circulating valve  Charge valve pump  Expansion vessel  Flexible coupling  Pressure gauges  Safety valve  Plate-type heat  Manual shut-off valves exchanger drain valve Typical wa

Summary of the content on the page No. 8

30RA/30RH Water connections ENGLISH Ethylene glycol curve ATTENTION: The pump leakproof components are not suitable for use with propylene glycol. CAUTION: Weight concentration of ethylene glycol in water % Using water with glycol may make it necessary to change the configuration of the control system. Make the plate heat exchanger hydraulic connections with the It is therefore necessary to protect the heat exchanger inlet with necessary components, using material which will guarantee that an ex

Summary of the content on the page No. 9

30RA/30RH Water connections Water pressure drop of the unit without hydronic module A. 30RA-RH 017 B. 30RA-RH 021 C. 30RA-RH 026 D. 30RA-RH 033 Water flow rate, l/s Outlet available static pressure of the unit with hydronic module A. 30RA-RH 017 B. 30RA-RH 021 C. 30RA-RH 026 D. 30RA-RH 033 Water flow rate, l/s GB - 8 Pressure drop , kPa Available static pressure, kPa

Summary of the content on the page No. 10

30RA/30RH Electrical connections and refrigerant charge ENGLISH Electrical connections Liquid refrigerant charge Checking the charge WARNING: To prevent electrical shock or equipment damage, make sure WARNING: disconnects are open before electrical connections are made. When adjusting the refrigerant charge always ensure that If this action is not taken, personal injury may occur. water is circulating in the heat exchanger to prevent any possibility of freezing up. Damage caused by freezing is n

Summary of the content on the page No. 11

30RA/30RH Refrigerant charge and electronic control Undercharge Electronic control If there is not enough refrigerant in the system, this is indicated by gas bubbles in the moisture sight glass. Operation and control of all units is carried out via the electronic control. There are two possibilities: The instructions supplied with the control include comprehensive descriptions. • Small undercharge (bubbles in the sight glass, no significant change in suction pressure). - After detection and repa

Summary of the content on the page No. 12

30RA/30RH Start-up, compressor and pump replacement, unit protection devices ENGLISH Start-up Unit start-up is done by the electronic control described above, and must always be carried out under the supervision of a qualified air conditioning engineer. Necessary checks/precautions before start-up - Ensure that all electrical connections are properly tightened.  - Ensure that the unit is level and well-supported. - Check that the hydraulic circuit has sufficient water flow and that the pipe con

Summary of the content on the page No. 13

30RA/30RH Unit protection devices, operating limits and operating range Table III: Pressure switch settings NOTE: For industrial process cooling applications, where high Cut-out Reset stability of water temperature levels must be achieved, the High pressurestat 30 bar Manual values above must be increased. WARNING: We recommend consulting the factory for these particular Alteration of factory settings other than the design set-point, without applications. manufacturer's authorisation, may void t

Summary of the content on the page No. 14

30RA/30RH General maintenance, maintenance and final recommendations ENGLISH Cleaning should be done at regular intervals and should never be General maintenance left until the unit has become blocked. The time intervals between cleaning depend on the quality of the ATTENTION: water used, but as a general rule it is advisable to clean it at least Before starting any servicing or maintenance operation on the unit, once a year. make sure that the power supply has been disconnected. - Refrigerant c

Summary of the content on the page No. 15

30RA/30RH Troubleshooting A list of possible faults, as well as the probable cause and - Badly fitting panels; suggested solutions is shown as follows. In the event of a unit INSTALL CORRECTLY. malfunction it is recommended to disconnect the power supply and ascertain the cause. Compressor loses oil: - Leaking refrigeration circuit; Symptoms Cause REMEDY REPAIR LEAK. Water loss: Unit does not start: - Defective entering or leaving connections; - No power supply; CHECK AND TIGHTEN IF NECESSARY. C

Summary of the content on the page No. 16

L010126H27 - 0405 Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change any product specifications without notice. Order No. 13024-74 April 2005. Supersedes Order No. 13024-74, June 2004. Printed in Italy


Alternative user manuals
# User manual Category Download
1 Carrier 25HCR3C User manual Heat Pump 48
2 Carrier 10 SEER SPLIT-SYSTEM 38YCW User manual Heat Pump 19
3 Carrier 38AC User manual Heat Pump 10
4 Carrier 38AN,BK User manual Heat Pump 14
5 Carrier 25HCS3C User manual Heat Pump 8
6 Carrier 25HBB User manual Heat Pump 5
7 Carrier 38AQ028 User manual Heat Pump 5
8 Carrier 38BYB User manual Heat Pump 4
9 Carrier 38AQ024 User manual Heat Pump 4
10 Carrier 380B User manual Heat Pump 4
11 Carrier 38AUQ User manual Heat Pump 37
12 Carrier 38AYB User manual Heat Pump 1
13 Carrier 38BYC User manual Heat Pump 4
14 Carrier 38AQ034 User manual Heat Pump 2
15 Carrier 38QB User manual Heat Pump 1
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5