Bard WH602 user manual

User manual for the device Bard WH602

Device: Bard WH602
Category: Heat Pump
Manufacturer: Bard
Size: 0.3 MB
Added : 5/22/2014
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bard WH602. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bard WH602.

For your convenience

If looking through the Bard WH602 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bard WH602 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bard WH602 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bard WH602 User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bard WH602 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bard WH602. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
WALL MOUNTED
PACKAGE HEAT PUMPS
MODELS:
WH421
WH483
WH602
Manual: 2100-399
BARD MANUFACTURING COMPANY
Supersedes:
Bryan, Ohio 43506
File: Volume III Tab 17
Since 1914...Moving ahead, just as planned.
Date: 03-01-02
Copyright 2002

Summary of the content on the page No. 2

CONTENTS Getting Other Information and Publications .......... 1 Start Up ................................................................... 14 For more information, contact these publishers: ...... 1 Important Installer Note .......................................... 14 High Pressure Switch ............................................. 14 Wall Mount General Information ............................. 2 Three Phase Scroll Compressor Start Up Air Conditioner Wall Mount Model Nomenclature ..... 2 I

Summary of the content on the page No. 3

Getting Other Information and Publications These publications can help you install the air FOR MORE INFORMATION, CONTACT conditioner or heat pump. You can usually find these at THESE PUBLISHERS: your local library or purchase them directly from the publisher. Be sure to consult current edition of each ACCA Air Conditioning Contractors of America standard. 1712 New Hampshire Ave. N.W. Washington, DC 20009 Telephone: (202) 483-9370 National Electrical Code ....................... ANSI/NFPA 70 Fax:

Summary of the content on the page No. 4

WALL MOUNT GENERAL INFORMATION HEAT PUMP WALL MOUNT MODEL NOMENCLATURE MODEL NUMBER CONTROL MODULES (See Chart Below) WH 48 1 – A 10 X X X X X B CAPACITY COIL OPTIONS 42 – 3-1/2 Ton REVISION X – Standard 48 – 4 Ton 1 – Phenolic Coated Evaporator 60 – 5 Ton VENTILATION OPTIONS 2 – Phenolic Coated Condenser VOLTS & PHASE X – Barometric Fresh Air Damper 3 – Phenolic Coated Evaporator (Standard) A – 230/208/60-1 and Condenser COLOR OPTIONS B – 230/208/60-

Summary of the content on the page No. 5

Manual 2100-399 Page 3 FIGURE 1 UNIT DIMENSIONS MIS-411

Summary of the content on the page No. 6

TABLE 2 ELECTRICAL SPECIFICATIONS SINGLE CIRCUIT DUAL CIRCUIT 4 1 2 2 4 1 2 2 Maximum Maximum Minimum External No. External Field Circuit Fuse or Field Power Ground Wire Rated Field Minimum Fuse or Power Ground Ampacity Ckt.Breaker Wire Size Size Volts Power Circuit Circuit Wire Wire & Phase Ckts. Model Ampacity Breaker Size SizeCB ktACA ktCB ktCA ktCB ktCA ktCB kt Ckt WH421-A00,A0Z 1 34 50 8 10 N/A N/A N/A N/A N/A N/A N/A N/A A05 1 or 2 60 70 6 8 34 26 50 30 8 10 10 10 230/208-1 3 A10 1 or 2 8

Summary of the content on the page No. 7

Refer to Table 10 for maximum static pressure available SHIPPING DAMAGE for duct design. Upon receipt of equipment, the carton should be Design the duct work according to methods given by the checked for external signs of shipping damage. If damage is found, the receiving party must contact the Air Conditioning Contractors of America (ACCA). When duct runs through unheated spaces, it should be last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent. insulate

Summary of the content on the page No. 8

FRESH AIR INTAKE CONDENSATE DRAIN All units are built with fresh air inlet slots punched in A plastic drain hose extends from the drain pan at the the service panel. top of the unit down to the unit base. There are openings in the unit base for the drain hose to pass If the unit is equipped with the fresh air damper through. In the event the drain hose is connected to a assembly, the assembly is shipped already attached to drain system of some type, it must be an open or vented the unit. The da

Summary of the content on the page No. 9

INSTALLATION INSTRUCTIONS WALL MOUNTING INFORMATION 1. Two holes, for the supply and return air openings, WARNING must be cut through the wall as shown in Figure 3. 2. On wood-frame walls, the wall construction must be Failure to provide the 1/4 inch clearance strong and rigid enough to carry the weight of the between the supply duct and a combustible unit without transmitting any unit vibration. See surface for the first 3 feet of duct can result in Figures 4 and 5. fire.

Summary of the content on the page No. 10

FIGURE 3 MOUNTING INSTRUCTIONS NOTE: It is recommended that a bead of silicone caulking be placed behind the side mounting flanges and under the top flashing at the time of installation. MIS-796 FIGURE 3A ELECTRIC HEAT CLEARANCE WARNING  A minimum of 1/4 inch clearance must be maintained between the supply air duct and combustible materials. This is required for the first 3 feet of ducting.  It is important to insure that the 1/4 inch minimum spacing is maintained at all points.

Summary of the content on the page No. 11

FIGURE 4 WALL-MOUNTING INSTRUCTIONS SEE FIGURE 3 — MOUNTING INSTRUCTIONS MIS-548 FIGURE 5 WALL-MOUNTING INSTRUCTIONS SEE UNIT DIMENSIONS, FIGURE 1, FOR ACTUAL DIMENSIONS SEE FIGURE 1 FOR DUCT DIMENSIONS MIS-549 Manual 2100-399 Page 9

Summary of the content on the page No. 12

FIGURE 6 COMMON WALL-MOUNTING INSTALLATIONS MIS-550 Manual 2100-399 Page 10

Summary of the content on the page No. 13

NOTE:The voltage should be measured at the field power WIRING — MAIN POWER connection point in the unit and while the unit is Refer to the unit rating plate for wire sizing operating at full load (maximum amperage information and maximum fuse or “HACR" type operating condition). circuit breaker size. Each outdoor unit is marked Nine (9) wires should be run from thermostat subbase to with a “Minimum Circuit Ampacity”. This means the 24V terminal board in the unit. A nine conductor, 18 that the fi

Summary of the content on the page No. 14

Outdoor thermostats are available to hold off various TABLE 3 banks of electric heat until needed as determined by THERMOSTAT WIRE SIZE outdoor temperature. The set point of either type of Maximum thermostat is variable with geographic region and Transformer Distance sizing of the heating equipment to the structure VA AFe L Wire Gaug In Feet Utilization of the Heating Application Data and the 20 gauge 45 heat loss calculation of the building are useful in 18 gauge 60 determining the correct se

Summary of the content on the page No. 15

TABLE 4 WALL THERMOSTAT AND SUBBASE COMBINATIONS Te hermostatSs ubbas PredominantFeature 8403-045 1 stg.cool;2 stg.heat;Mercurybulb - - - (T841A1761) Manualchangeover 8403-017 8404-009 2 stg.cool;2 stg.heat;Mercurybulb (T874R1129) (Q674L1181) Manualchangeover 8403-018 8404-010 2 stg.cool;2 stg.heat;Mercurybulb (T874N1024) (Q674F1261) Auto or Manualchangeover 1 stg.cool;2 stg.heat 8403-042 - - - Electronic Non-Programmable (T8511G1070) Auto or Manualchangeover 2 stg.cool;2 stg.heat 8403-049 - -

Summary of the content on the page No. 16

START UP FIGURE 9 IMPORTANT INSTALLER NOTE START UP LABEL For improved start-up performance, wash the indoor coil with a dishwashing detergent. IMPORTANT THESE PROCEDURES MUST BE CRANKCASE HEATERS FOLLOWED AT INITIAL START UP AND AT ANY TIME POWER HAS WA421 units are provided with compressor crankcase heat. WH602 and WH483 units are not provided with BEEN REMOVED FOR 12 HOURS crankcase heat. These units utilize scroll compressors OR LONGER. which do not require crankcase heat in this applicat

Summary of the content on the page No. 17

now in operation. The second option has no "Auto" PHASE MONITOR changeover position, but instead energizes the reversing All units with three phase compressors are equipped valve solenoid constantly whenever the system switch with a 3 phase line monitor to prevent compressor on subbase is placed in "Heat" position, the "B" damage due to phase reversal. terminal being constantly energized from R. A The phase monitor in this unit is equipped with two Thermostat demand for heat completes r-Y circ

Summary of the content on the page No. 18

As soon as the defrost cycle kicks in, remove the There are three time settings on the HPC — 30, 60 or shorting instrument from the SPEEDUP terminals. on minutes. These are elapsed run-time values, and the Otherwise the timing will remain accelerated and run outdoor coil temperature sensor must be below the 30 through the 10-minute maximum defrost length degree equivalent resistance value for the timer to sequence in a matter of seconds and will automatically accumulate time towards the actual

Summary of the content on the page No. 19

TROUBLESHOOTING 4. Set system to heat or cool. Adjust thermostat to call SOLID STATE HEAT PUMP CONTROL for heat or cool – the indoor blower, compressor, TROUBLESHOOTING PROCEDURE and outdoor fan should start. 1. Turn on AC power supply to indoor and outdoor units. NOTE:If there was no power to 24 volt transformer, the compressor and outdoor fan motor will not start 2. Turn thermostat blower switch to fan "on" – the for 5 minutes. This is because of the compressor indoor blower should start

Summary of the content on the page No. 20

CHECKING TEMPERATURE SENSOR 3. Check resistance reading to chart of resistance. Use OUTSIDE UNIT CIRCUIT sensor ambient temperature. (Tolerance of part is ± 10%.) 1. Disconnect temperature sensor from board and from outdoor coil. 4. If sensor resistance reads very low, then sensor is shorted and will not allow proper operation of the 2. Use an ohmmeter and measure the resistance of the heat pump control. sensor. Also use ohmmeter to check for short or open. 5. If sensor is out of tolerance, s


Alternative user manuals
# User manual Category Download
1 Bard Mfg. Co.I30H1 User manual Heat Pump 0
2 Bard Mfg. Co.GSVS361-A User manual Heat Pump 4
3 Bard Mfg. Co.I36H1D User manual Heat Pump 0
4 Bard Mfg. Co.CH5S1 User manual Heat Pump 1
5 Bard Mfg. Co.CH4S1 User manual Heat Pump 3
6 Bard Mfg. Co.I36H1 User manual Heat Pump 0
7 Bard Mfg. Co.GVDM-26 User manual Heat Pump 0
8 Bard Mfg. Co.GSVS301-A User manual Heat Pump 0
9 Bard Mfg. Co.I42H1D User manual Heat Pump 0
10 Bard Mfg. Co.I60H1D User manual Heat Pump 0
11 Bard Mfg. Co.W**H*D User manual Heat Pump 0
12 Bard Mfg. Co.T**H User manual Heat Pump 1
13 Bard Mfg. Co.W24H1D User manual Heat Pump 0
14 Bard Mfg. Co.S**H*D User manual Heat Pump 0
15 Bard Mfg. Co.W24H1 User manual Heat Pump 4
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5